A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

Abstract:

:Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automatic segmentation of possible sperm shapes and classification of normal/ab-normal sperms. In the segmentation step, clustering techniques with/without group sparsity approach were tested to extract region of interests from the images. Subsequently, a novel publicly available morphological sperm image data set, whose labels were identified by experts as non-sperm, normal and abnormal sperm, was created as the ground truths of classification step. In the classification step, conventional and ensemble machine learning methods were applied to domain-specific features that were extracted by using wavelet transform and descriptors. Additionally, as an alternative to conventional features, three deep neural network architectures, which can extract high-level features from raw images after using statistical learning, were employed to increase the proposed method's performance. The results show that, for the conventional features, the highest classification accuracies were achieved as 80.5% and 83.8% by using the wavelet- and descriptor-based features that were fed to the Support Vector Machines respectively. On the other hand, the Mobile-Net, which is a very convenient network for smartphones, achieved 87% accuracy. In the light of obtained results, it is seen that a fully automatic hybrid system, which uses the group sparsity to enhance segmentation performance and the Mobile-Net to obtain high-level robust features, can be an effective mobile solution for the sperm morphology analysis problem. A fully automated hybrid human sperm detection and classification system based on mobile-net.

journal_name

Med Biol Eng Comput

authors

Ilhan HO,Sigirci IO,Serbes G,Aydin N

doi

10.1007/s11517-019-02101-y

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

1047-1068

issue

5

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-019-02101-y

journal_volume

58

pub_type

杂志文章
  • Object-shape recognition and 3D reconstruction from tactile sensor images.

    abstract::This article presents a novel approach of edged and edgeless object-shape recognition and 3D reconstruction from gradient-based analysis of tactile images. We recognize an object's shape by visualizing a surface topology in our mind while grasping the object in our palm and also taking help from our past experience of...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1142-1

    authors: Khasnobish A,Singh G,Jati A,Konar A,Tibarewala DN

    更新日期:2014-04-01 00:00:00

  • Inhibition of TNF-alpha induced cell death in human umbilical vein endothelial cells and Jurkat cells by protocatechuic acid.

    abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345308

    authors: Zhou-Stache J,Buettner R,Artmann G,Mittermayer C,Bosserhoff AK

    更新日期:2002-11-01 00:00:00

  • OKAS-3D: optoelectronic jaw movement recording system with six degrees of freedom.

    abstract::OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photoce...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510786

    authors: Naeije M,Van der Weijden JJ,Megens CC

    更新日期:1995-09-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • A mechatronic valve in the management of hydrocephalus: methods and performance.

    abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0716-9

    authors: Momani L,Al-Nuaimy W,Al-Jumaily M,Mallucci C

    更新日期:2011-01-01 00:00:00

  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00

  • Use of surface potential spectral characteristics for solving the inverse problem in electroneurography.

    abstract::The changes in the power spectra of single-fibre extracellular action potentials (SFEAPs) generated in an infinite anisotropic frequency-dependent volume conductor, which occurred as a result of alterations in the propagation velocity v and duration T(in) of the intracellular action potential (IAP) were analytically d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446167

    authors: Dimitrov GV,Lateva ZC,Dimitrova NA

    更新日期:1992-07-01 00:00:00

  • Automatic interpretation of hyperventilation-induced electroencephalogram constructed in the way of qualified electroencephalographer's visual inspection.

    abstract::Quantitative analysis and detection of electroencephalogram (EEG) recordings during evoked activities is essential for clinical diagnosis on neurological disorders. However, the process of interpreting EEG is time consuming for electroencephalographers (EEGers). In this study, an automatic EEG interpretation system co...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0688-9

    authors: Zhang X,Wang X,Sugi T,Ikeda A,Nagamine T,Shibasaki H,Nakamura M

    更新日期:2011-02-01 00:00:00

  • A machine learning approach for magnetic resonance image-based mouse brain modeling and fast computation in controlled cortical impact.

    abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02262-1

    authors: Lai C,Chen Y,Wang T,Liu J,Wang Q,Du Y,Feng Y

    更新日期:2020-11-01 00:00:00

  • Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique.

    abstract::Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344797

    authors: Mitulescu A,Semaan I,De Guise JA,Leborgne P,Adamsbaum C,Skalli W

    更新日期:2001-03-01 00:00:00

  • Duchenne muscular dystrophy quantification: a multivariate analysis of surface EMG.

    abstract::The paper describes a method of quantifying Duchenne muscular dystrophy which is examiner independent and uses surface electromyographic signals (EMG). A standardised protocol is proposed. Spectral parameters are first computed from digitised EMG, then a polynomial model is deduced from the evolution of each parameter...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446966

    authors: Priez A,Duchene J,Goubel F

    更新日期:1992-05-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • CFD simulations for paper-based DNA amplification reaction (LAMP) of Mycobacterium tuberculosis-point-of-care diagnostic perspective.

    abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02082-y

    authors: Das D,Panigrahi PK

    更新日期:2020-02-01 00:00:00

  • Intelligent prediction of kinetic parameters during cutting manoeuvres.

    abstract::Due to its capabilities in analysing injury risk, the ability to analyse an athlete's ground reaction force and joint moments is of high interest in sports biomechanics. However, using force plates for the kinetic measurements influences the athlete's performance. Therefore, this study aims to use a feed-forward neura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02000-2

    authors: Mundt M,David S,Koeppe A,Bamer F,Markert B,Potthast W

    更新日期:2019-08-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Three-dimensional changes of the cytoskeleton of vascular endothelial cells exposed to sustained hydrostatic pressure.

    abstract::The three-dimensional changes in the cytoskeleton and in cell proliferation of bovine pulmonary artery endothelial cells when exposed to sustained hydrostatic pressure were investigated in vitro using laser scanning confocal microscopy. Subconfluent endothelial cells on rigid substrates were exposed to 1.5, 5 and 10 c...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523225

    authors: Salwen SA,Szarowski DH,Turner JN,Bizios R

    更新日期:1998-07-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Spatio-spectral filters for low-density surface electromyographic signal classification.

    abstract::In this paper, we proposed to utilize a novel spatio-spectral filter, common spatio-spectral pattern (CSSP), to improve the classification accuracy in identifying intended motions based on low-density surface electromyography (EMG). Five able-bodied subjects and a transradial amputee participated in an experiment of e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1024-3

    authors: Huang G,Zhang Z,Zhang D,Zhu X

    更新日期:2013-05-01 00:00:00

  • Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics.

    abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1055-4

    authors: Marom G,Kim HS,Rosenfeld M,Raanani E,Haj-Ali R

    更新日期:2013-08-01 00:00:00

  • Effects of sino-aortic denervation on spectral characteristics of blood pressure and pulse interval variability: a wide-band approach.

    abstract::Sino-aortic denervation (SAD) is employed in cats to evaluate the baroreflex influence on blood pressure (BP) and pulse interval (PI) spectral components from 0.00008 to 0.9 Hz as assessed by FFT wide-band spectra and their 1/f modelling; and the linear coupling between BP and PI and between systolic and diastolic BP ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520018

    authors: Di Rienzo M,Castiglioni P,Parati G,Mancia G,Pedotti A

    更新日期:1996-03-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Effect of flow disturbances remaining at the beginning of diastole on intraventricular diastolic flow and colour M-mode Doppler echocardiograms.

    abstract::A computational model of the fluid dynamics of intraventricular flow was used to investigate the importance of the effects of flow disturbances existing within the left ventricle (LV) at the onset of diastole on a diastolic flow field. The simulation started with a quiescent flow state; it continued for a number of ca...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02350992

    authors: Nakamura M,Wada S,Mikami T,Kitabatake A,Karino T,Yamaguchi T

    更新日期:2004-07-01 00:00:00

  • Morphology analysis of vertebral trabecular bone under dynamic loading based on multi-scale theory.

    abstract::Trabecular bone has a complicated porous microstructure and consists of interconnected plates and rods known as trabeculae. The microarchitecture of the trabeculae contributes to load distribution capacity and, particularly, the optimal bone strength. Many previous studies have shown that morphological parameters are ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0951-3

    authors: Basaruddin KS,Takano N,Yoshiwara Y,Nakano T

    更新日期:2012-10-01 00:00:00

  • Computer-controlled positive displacement pump for physiological flow simulation.

    abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446086

    authors: Holdsworth DW,Rickey DW,Drangova M,Miller DJ,Fenster A

    更新日期:1991-11-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1256-0

    authors: Akça K,Eser A,Çavuşoğlu Y,Sağırkaya E,Çehreli MC

    更新日期:2015-05-01 00:00:00