Interaction between steady flow and individualised compliant segments: application to upper airways.

Abstract:

:To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a conceptual point of view, of local differences in anatomical and physiological properties between pharyngeal regions. The evolution of inspiratory flow and area variations were predicted using the transmural pressure at the downstream element as the controlled variable. Derivation and normalisation of fundamental governing equations, written for non-viscous and viscous fluids, reveal very different kinds of behaviour, depending on values of the speed index defined from the local distensibility, or its modulation by a friction factor for viscous fluid. The two-element model is able to describe a considerably rich mechanical behaviour, including the occurrence of critical conditions when area becomes very high or small, i.e. when the distensibility-dependent speed index at the upstream element tends toward unity. In spite of its simplicity, not only does the present model describe steady state behaviours that resemble the well-known phenomenon of choking in an elastic tube, but the viscous fluid conditions also reveal (i) an area evolution following a typical doubly folded shape, (ii) the occurrence of a close succession maximum and minimum flows which can be seen as a physiological 'flow plateau'. It is concluded that the concept of interaction behind the two-element model must be considered as soon as flow interacts in a compliant structure characterised by anatomical and/or functional singularities.

journal_name

Med Biol Eng Comput

authors

Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

doi

10.1007/BF02510972

subject

Has Abstract

pub_date

1997-11-01 00:00:00

pages

638-48

issue

6

eissn

0140-0118

issn

1741-0444

journal_volume

35

pub_type

杂志文章
  • Improved photomultiplier tube for positron emission tomography.

    abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441486

    authors: Woldeselassie T

    更新日期:1989-05-01 00:00:00

  • GFNB: Gini index-based Fuzzy Naive Bayes and blast cell segmentation for leukemia detection using multi-cell blood smear images.

    abstract::The blood cell counting and classification ensures the evaluation and diagnosis of a number of diseases. The analysis of white blood cells (WBCs) permits us to detect the acute lymphoblastic leukemia (ALL), a type of blood cancer that causes fatality when untreated. At present, the morphological analysis of blood cell...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02249-y

    authors: Das BK,Dutta HS

    更新日期:2020-11-01 00:00:00

  • Velocity distribution model for normal blood flow in the human ascending aorta.

    abstract::During the study of velocities in the human ascending aorta it became necessary to establish a method for two-dimensional velocity profiles from discrete velocity data obtained from different heartbeats and with different techniques. A descriptive geometrical model was therefore developed and expanded to 16 elements e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442319

    authors: Segadal L

    更新日期:1991-09-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • Angular relational signature-based chest radiograph image view classification.

    abstract::In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We presen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1786-3

    authors: Santosh KC,Wendling L

    更新日期:2018-08-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Detection of compressed tracheal sound patterns with large amplitude variation during sleep.

    abstract::The objective of the present work was to develop automated methods for the compressed tracheal breathing sound analysis. Overnight tracheal breathing sound was recorded from ten apnoea patients. From each patient, three different types of tracheal sound deflection pattern, each of 10 min duration, were visually scored...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0317-z

    authors: Kulkas A,Rauhala E,Huupponen E,Virkkala J,Tenhunen M,Saastamoinen A,Himanen SL

    更新日期:2008-04-01 00:00:00

  • Motorised resection device for transurethral resection of the prostate: a laboratory evaluation.

    abstract::Transurethral resection of the prostate is the most common method of relieving urinary outflow obstruction secondary to prostatic enlargement. However, this procedure can be responsible for various complications, including irrigant-fluid absorption and blood loss, both of which are strongly dependent on operation dura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510962

    authors: Mestas JL,Cathignol D,Chavrier F,Devonec M

    更新日期:1997-11-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Empirical quantification of internal and external rotation muscular co-activation ratios in healthy shoulders.

    abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1081-2

    authors: Brookham RL,Dickerson CR

    更新日期:2014-03-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00

  • Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

    abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349982

    authors: Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

    更新日期:2003-11-01 00:00:00

  • Clinical application of modified bag-of-features coupled with hybrid neural-based classifier in dengue fever classification using gene expression data.

    abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1722-y

    authors: Chatterjee S,Dey N,Shi F,Ashour AS,Fong SJ,Sen S

    更新日期:2018-04-01 00:00:00

  • A weighted ensemble-based active learning model to label microarray data.

    abstract::Classification of cancerous genes from microarray data is an important research area in bioinformatics. Large amount of microarray data are available, but it is very costly to label them. This paper proposes an active learning model, a semi-supervised classification approach, to label the microarray data using which p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02238-1

    authors: De R,Chakraborty A,Chatterjee A,Sarkar R

    更新日期:2020-10-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.

    abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1589-3

    authors: Mi Y,Rui S,Li C,Yao C,Xu J,Bian C,Tang X

    更新日期:2017-07-01 00:00:00

  • Biomechanical analysis of the muscular power of martial arts athletes.

    abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0608-z

    authors: Machado SM,Osório RA,Silva NS,Magini M

    更新日期:2010-06-01 00:00:00

  • Cephalometric image analysis and measurement for orthognathic surgery.

    abstract::Automatic identification of landmarks in cephalometry is very important and useful for orthognathic surgery. A computerised automatic cephalometric analysis system (CACAS), based on image processing, is presented. For an original X-ray image, median filtering and histogram equalisation are used to improve image qualit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345280

    authors: Yang J,Ling X,Lu Y,Wei M,Ding G

    更新日期:2001-05-01 00:00:00

  • Continuous cardiac output monitoring system.

    abstract::A continuous cardiac output monitoring system has been developed in the laboratory to allow the real-time measurement of the cardiac output. This form of continuous cardiac output measurement allows the doctor to view the beat-to-beat cardiac output and can be employed to measure artery constrictions as well. The sens...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345272

    authors: Tjin SC,Ho YC,Lam YZ,Hao J,Ng BK

    更新日期:2001-01-01 00:00:00

  • Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access.

    abstract::Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to ch...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345123

    authors: Mansy HA,Hoxie SJ,Patel NH,Sandler RH

    更新日期:2005-01-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Plasma detection of NO by a catheter.

    abstract::Nitric oxide (NO) released by endothelial cells in response to hemodynamic shear stress is a key controller molecule of the vascular functions and antiatherogenic mechanisms. Endothelial dysfunction is associated with increased cardiovascular events. Therefore, several indirect techniques have been employed to evaluat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0333-z

    authors: Goto M,Mochizuki S

    更新日期:2008-05-01 00:00:00

  • Frequency range extension of spectral analysis of pulse rate variability based on Hilbert-Huang transform.

    abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1135-5

    authors: Chang CC,Hsiao TC,Hsu HY

    更新日期:2014-04-01 00:00:00

  • The formation of extracellular potentials over the innervation zone: Are these potentials affected by changes in fibre membrane properties?

    abstract::Widespread misconceptions still exist regarding the formation of extracellular potentials over the innervation zone: the assumption (1) that the first phase of these potentials mainly reflects the process of initiation of the intracellular action potential (IAP) at the neuromuscular junction and that (2) these potenti...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1487-8

    authors: Rodriguez-Falces J

    更新日期:2016-12-01 00:00:00

  • Estimating germinability of Plasmopara viticola oospores by means of neural networks.

    abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344698

    authors: Vercesi A,Sirtori C,Vavassori A,Setti E,Liberati D

    更新日期:2000-01-01 00:00:00

  • Real time monitoring and analysis via the medical information bus, Part II.

    abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525536

    authors: Taboada JA,Arcay B,Arias JE

    更新日期:1997-09-01 00:00:00

  • On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation.

    abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348430

    authors: Fridolin I,Lindberg LG

    更新日期:2003-05-01 00:00:00

  • Rheological modelling of leukocytes.

    abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510753

    authors: Tran-Son-Tay R,Kan HC,Udaykumar HS,Damay E,Shyy W

    更新日期:1998-03-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00