A weighted ensemble-based active learning model to label microarray data.

Abstract:

:Classification of cancerous genes from microarray data is an important research area in bioinformatics. Large amount of microarray data are available, but it is very costly to label them. This paper proposes an active learning model, a semi-supervised classification approach, to label the microarray data using which predictions can be made even with lesser amount of labeled data. Initially, a pool of unlabeled instances is given from which some instances are randomly chosen for labeling. Successive selection of instances to be labeled from unlabeled pool is determined by selection algorithms. The proposed method is devised following an ensemble approach to combine the decisions of three classifiers in order to arrive at a consensus which provides a more accurate prediction of the class label to ensure that each individual classifier learns in an uncorrelated manner. Our method combines the heuristic techniques used by an active learning algorithm to choose training samples with the multiple learning paradigm attained by an ensemble to optimize the search space by choosing efficiently from an already sparse learning pool. On evaluating the proposed method on 10 microarray datasets, we achieve performance which is comparable with state-of-the-art methods. The code and datasets are given at https://github.com/anuran-Chakraborty/Active-learning. Flowchart of the proposed ensemble-based active learning framework.

journal_name

Med Biol Eng Comput

authors

De R,Chakraborty A,Chatterjee A,Sarkar R

doi

10.1007/s11517-020-02238-1

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

2427-2441

issue

10

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-020-02238-1

journal_volume

58

pub_type

杂志文章
  • Sub-threshold depolarizing pre-pulses can enhance the efficiency of biphasic stimuli in transcutaneous neuromuscular electrical stimulation.

    abstract::There is multiple evidence in the literature that a sub-threshold pre-pulse, delivered immediately prior to an electrical stimulation pulse, can alter the activation threshold of nerve fibers and motor unit recruitment characteristics. So far, previously published works combined monophasic stimuli with sub-threshold d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1851-y

    authors: Vargas Luna JL,Mayr W,Cortés-Ramirez JA

    更新日期:2018-12-01 00:00:00

  • Corrected formula for estimating peripheral blood flow by impedance plethysmography.

    abstract::In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524237

    authors: Jindal GD,Nerurkar SN,Pednekar SA,Babu JP,Bhuta AC,Deshpande AK

    更新日期:1994-11-01 00:00:00

  • Functional evaluation of triceps surae during heel rise test: from EMG frequency analysis to machine learning approach.

    abstract::Soleus muscle flap as coverage tissue is a possible surgical solution adopted to cover the wounds due to open fractures. Despite this procedure presents many clinical advantages, relatively poor information is available about the loss of functionality of triceps surae of the treated leg. In this study, a group of pati...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02286-7

    authors: Ferracuti F,Fioretti S,Frontoni E,Iarlori S,Mengarelli A,Riccio M,Romeo L,Verdini F

    更新日期:2021-01-01 00:00:00

  • Detection of the movement of the humerus during daily activity.

    abstract::A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory settin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0464-x

    authors: Coley B,Jolles BM,Farron A,Aminian K

    更新日期:2009-05-01 00:00:00

  • Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study.

    abstract::A computer-aided method was developed to automatically localize tumors in lung PET images of discrete bins within the breathing cycle, followed by an algorithm that registers all the information of a complete respiratory cycle into a single reference bin. Four registration/integration algorithms: Centroid Based, Inten...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0549-6

    authors: Wang J,del Valle M,Goryawala M,Franquiz JM,McGoron AJ

    更新日期:2010-01-01 00:00:00

  • Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

    abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1752-5

    authors: Naidu SMM,Pandey PC,Bagal UR,Hardas SP

    更新日期:2018-06-01 00:00:00

  • The past, present, and prospective on UV-VIS-NIR skin photonics and spectroscopy-a wavelength guide.

    abstract::The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a cl...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-019-02077-9

    authors: Poh AH,Adikan FRM,Moghavvemi M

    更新日期:2020-06-01 00:00:00

  • Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.

    abstract::Instantaneous backflow through central clearance of bileaflet heart valves at the instant of closure is investigated. An Edwards-Duromedics valve in the mitral position is employed to measure the transient pressures near the entrance and exit region in an in vitro flow chamber. A region surrounding the clearance is mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510497

    authors: Lee CS,Chandran KB

    更新日期:1995-05-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • An atlas-based multimodal registration method for 2D images with discrepancy structures.

    abstract::An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1808-1

    authors: Lv W,Chen H,Peng Y,Li Y,Li J

    更新日期:2018-11-01 00:00:00

  • Dialysate-side urea kinetics. Neural network predicts dialysis dose during dialysis.

    abstract::Determination of the adequacy of dialysis is a routine but crucial procedure in patient evaluation. The total dialysis dose, expressed as Kt/V, has been widely recognised to be a major determinant of morbidity and mortality in haemodialysed patients. Many different factors influence the correct determination of Kt/V, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348080

    authors: Fernández EA,Valtuille R,Willshaw P,Perazzo CA

    更新日期:2003-07-01 00:00:00

  • "Hippocrates-mst": a prototype for computer-aided microcalcification analysis and risk assessment for breast cancer.

    abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0117-2

    authors: Spyrou G,Kapsimalakou S,Frigas A,Koufopoulos K,Vassilaros S,Ligomenides P

    更新日期:2006-11-01 00:00:00

  • Atrial septal defect: a diagnostic approach.

    abstract::A simple objective screening method for diagnosis of the atrial septal defect (ASD) is needed. Acoustic signals were collected from 61 children with ASD and 60 with a physiological murmur. The second heart sound (S2) and the spectrum of systolic murmur were analysed. A statistical model was designed using stepwise log...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0094-5

    authors: El-Segaier M,Pesonen E,Lukkarinen S,Peters K,Ingemansson J,Sörnmo L,Sepponen R

    更新日期:2006-09-01 00:00:00

  • Use of surface potential spectral characteristics for solving the inverse problem in electroneurography.

    abstract::The changes in the power spectra of single-fibre extracellular action potentials (SFEAPs) generated in an infinite anisotropic frequency-dependent volume conductor, which occurred as a result of alterations in the propagation velocity v and duration T(in) of the intracellular action potential (IAP) were analytically d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446167

    authors: Dimitrov GV,Lateva ZC,Dimitrova NA

    更新日期:1992-07-01 00:00:00

  • Role of the calcaneal inclination in the energy storage capacity of the human foot--a biomechanical model.

    abstract::The energy storage capacity of the human foot as a passive structure depends on both its geometry and elastic properties. The present study examines theoretically the relationship between the energy stored in the longitudinal arch and the inclination of the calcaneus, when a vertical load is applied. A simple two-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441770

    authors: Simkin A,Leichter I

    更新日期:1990-03-01 00:00:00

  • Chaotic behavior of the coronary circulation.

    abstract::The regulation of the coronary circulation is a complex paradigm in which many inputs that influence vasomotor tone have to be integrated to provide the coronary vasomotor adjustments to cardiac metabolism and to perfusion pressure. We hypothesized that the integration of many disparate signals that influence membrane...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0329-8

    authors: Trzeciakowski J,Chilian WM

    更新日期:2008-05-01 00:00:00

  • Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibility.

    abstract::Cerebral autoregulation controls cerebral blood flow under changing cerebral perfusion pressure. Standards for measurement and analysis of dynamic cerebral autoregulation (dCA) are lacking. In this study, dCA reproducibility, quantified by intraclass correlation coefficient, is evaluated for different methodological a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0706-y

    authors: Gommer ED,Shijaku E,Mess WH,Reulen JP

    更新日期:2010-12-01 00:00:00

  • Activating function of needle electrodes in anisotropic tissue.

    abstract::We present an analytical solution for the electrical potential and activating function (AF) established by cylindrical needle electrodes in anisotropic tissue. We compare this activating function to (1) AF computed assuming line-source electrodes and (2) AF computed using a finite element program. The results show tha...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0508-2

    authors: Guo L,Cranford JP,Neu JC,Neu WK

    更新日期:2009-09-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Estimation of the dynamics of event-related desynchronisation changes in electroencephalograms.

    abstract::A method for the estimation of medium rate transitions of non-stationary electroencephalograms (EEG) is proposed. The method is applicable to such EEG dynamics that are between (a) fast transitions for which segmentation procedures are used and (b) slow transitions for which adaptive filters work properly. The estimat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513305

    authors: Hiltunen JK,Karjalainen PA,Partanen J,Kaipio JP

    更新日期:1999-05-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Wireless and inductively powered implant for measuring electrocardiogram.

    abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-007-0264-0

    authors: Riistama J,Väisänen J,Heinisuo S,Harjunpää H,Arra S,Kokko K,Mäntylä M,Kaihilahti J,Heino P,Kellomäki M,Vainio O,Vanhala J,Lekkala J,Hyttinen J

    更新日期:2007-12-01 00:00:00

  • Vascular smooth muscle cells remodel collagen matrices by long-distance action and anisotropic interaction.

    abstract::While matrix remodeling plays a key role in vascular physiology and pathology, the underlying mechanisms have remained incompletely understood. We studied the remodeling of collagen matrices by individual vascular smooth muscle cells (SMCs), clusters and monolayers. In addition, we focused on the contribution of trans...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0916-6

    authors: van den Akker J,Tuna BG,Pistea A,Sleutel AJ,Bakker EN,van Bavel E

    更新日期:2012-07-01 00:00:00

  • Analysis and decision based on specialist self-assessment for prognosis factors of acute leukemia integrating data-driven Bayesian network and fuzzy cognitive map.

    abstract::The purpose of the present study is to analyze the prognostic factors of acute leukemia and to construct a decision model based on a causal relationship between the factors of this disease to assist medical specialists. In medical decisions, to reach effective, quick, and reliable results, there is a need for a simple...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02267-w

    authors: Jahangoshai Rezaee M,Sadatpour M,Ghanbari-Ghoushchi N,Fathi E,Alizadeh A

    更新日期:2020-11-01 00:00:00

  • Towards a patient-specific hepatic arterial modeling for microspheres distribution optimization in SIRT protocol.

    abstract::Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1703-1

    authors: Simoncini C,Jurczuk K,Reska D,Esneault S,Nunes JC,Bellanger JJ,Saint-Jalmes H,Rolland Y,Eliat PA,Bézy-Wendling J,Kretowski M

    更新日期:2018-03-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00