Detection of the movement of the humerus during daily activity.

Abstract:

:A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.

journal_name

Med Biol Eng Comput

authors

Coley B,Jolles BM,Farron A,Aminian K

doi

10.1007/s11517-009-0464-x

subject

Has Abstract

pub_date

2009-05-01 00:00:00

pages

467-74

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

47

pub_type

杂志文章
  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Evaluation of divided attention using different stimulation models in event-related potentials.

    abstract::Divided attention is defined as focusing on different tasks at once, and this is described as one of the biggest problems of today's society. Default examinations for understanding attention are questionnaires or physiological signals, like evoked potentials and electroencephalography. Physiological records were obtai...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02013-x

    authors: Batbat T,Güven A,Dolu N

    更新日期:2019-09-01 00:00:00

  • Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow.

    abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1818-z

    authors: Xu Z,Kleinstreuer C

    更新日期:2018-11-01 00:00:00

  • Effects of sino-aortic denervation on spectral characteristics of blood pressure and pulse interval variability: a wide-band approach.

    abstract::Sino-aortic denervation (SAD) is employed in cats to evaluate the baroreflex influence on blood pressure (BP) and pulse interval (PI) spectral components from 0.00008 to 0.9 Hz as assessed by FFT wide-band spectra and their 1/f modelling; and the linear coupling between BP and PI and between systolic and diastolic BP ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520018

    authors: Di Rienzo M,Castiglioni P,Parati G,Mancia G,Pedotti A

    更新日期:1996-03-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • A mechatronic valve in the management of hydrocephalus: methods and performance.

    abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0716-9

    authors: Momani L,Al-Nuaimy W,Al-Jumaily M,Mallucci C

    更新日期:2011-01-01 00:00:00

  • Heart rate and body temperature sensitive diaphragm pacing.

    abstract::Two ways of rate control for diaphragm pacing are proposed. One is rate control using only the patients' body temperature (method I). The other is rate control by both the patients' heart rate and body temperature (method II). To test the effectiveness of these methods, a diaphragm pacemaker which can be controlled by...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446125

    authors: Kimura M,Sugiura T,Fukui Y,Kimura T,Harada Y

    更新日期:1992-03-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Analysis of amplitude and frequency variations of essential and Parkinsonian tremors.

    abstract::Variations in the amplitude and period of essential and Parkinsonian tremors were studied. It was found that the variations in frequency (or period) were mostly similar to the white noise, with the standard deviation typically less than 10% of the mean, whereas the variations in amplitude were much larger, with standa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344710

    authors: Gao JB

    更新日期:2004-05-01 00:00:00

  • Simulation framework for electrophysiological networks: effect of syncytial properties on smooth-muscle synaptic potentials.

    abstract::A building block-based software framework was developed to simulate electrophysiological networks. The synaptic potentials generated during neurotransmission were simulated in an existing discrete bidomain model of smooth muscle, using cubic, three-dimensional grids of varying sizes. The model is automatically derived...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345322

    authors: Turale N,Devulapalli A,Manchanda R,Moudgalya K,Sivakumar G

    更新日期:2003-09-01 00:00:00

  • Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

    abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1355-y

    authors: Gholami-Boroujeny S,Bolic M

    更新日期:2016-04-01 00:00:00

  • A new method for measurement of motor unit action potential duration based on correlation, a pilot study.

    abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02115-6

    authors: Rodríguez Carreño I,Malanda A,Gila Useros L,Gurtubay IG,Navallas J,Rodríguez-Falces J

    更新日期:2020-03-01 00:00:00

  • Modeling the pharyngeal anatomical effects on breathing resistance and aerodynamically generated sound.

    abstract::The objective of this study was to systematically assess the effects of pharyngeal anatomical details on breathing resistance and acoustic characteristics by means of computational modeling. A physiologically realistic nose-throat airway was reconstructed from medical images. Individual airway anatomy such as the uvul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1160-z

    authors: Xi J,Si X,Kim J,Su G,Dong H

    更新日期:2014-07-01 00:00:00

  • Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

    abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0827-y

    authors: Bousbiat S,Jaffrin MY,Dongmo E

    更新日期:2011-11-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Dielectric properties of bones for the monitoring of osteoporosis.

    abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-018-1887-z

    authors: Amin B,Elahi MA,Shahzad A,Porter E,McDermott B,O'Halloran M

    更新日期:2019-01-01 00:00:00

  • Frequency range extension of spectral analysis of pulse rate variability based on Hilbert-Huang transform.

    abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1135-5

    authors: Chang CC,Hsiao TC,Hsu HY

    更新日期:2014-04-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Axial head rotation increases facet joint capsular ligament strains in automotive rear impact.

    abstract::Axial head rotation prior to low speed automotive rear impacts has been clinically identified to increase morbidity and symptom duration. The present study was conducted to determine the effect of axial head rotation on facet joint capsule strains during simulated rear impacts. The study was conducted using a validate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0682-2

    authors: Storvik SG,Stemper BD

    更新日期:2011-02-01 00:00:00

  • Personal computer system for ECG ST-segment recognition based on neural networks.

    abstract::A personal computer system for electrocardiogram (ECG) ST-segment recognition is developed based on neural networks. The system consists of a preprocessor, neural networks and a recogniser. The adaptive resonance theory (ART) is employed to implement the neural networks in the system, which self-organise in response t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446186

    authors: Suzuki Y,Ono K

    更新日期:1992-01-01 00:00:00

  • Delineation of the ischemic stroke lesion based on watershed and relative fuzzy connectedness in brain MRI.

    abstract::Precise segmentation of stroke lesions from brain magnetic resonance (MR) images poses a challenging task in automated diagnosis. In this paper, we proposed a new method called watershed-based lesion segmentation algorithm (WLSA), which is a novel intensity-based segmentation technique used to delineate infarct lesion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1726-7

    authors: Subudhi A,Jena S,Sabut S

    更新日期:2018-05-01 00:00:00

  • Sprouting from arteriovenous shunt vessels with increased blood flow.

    abstract::The purpose of this study was to evaluate the effect of increased blood flow on angiogenesis at the large vessels. The arteriovenous (AV) shunt was made on the thigh of male Wistar rats (n = 27) to increase blood flow, wrapped with artificial skin dermis, which consisted of a silicon outer layer, and isolated from sur...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345133

    authors: Asano Y,Ichioka S,Shibata M,Ando J,Nakatsuka T

    更新日期:2005-01-01 00:00:00

  • Combination of "generalized Trotter operator splitting" and "quadratic adaptive algorithm" method for tradeoff among speedup, stability, and accuracy in the Markov chain model of sodium ion channels in the ventricular cell model.

    abstract::The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo's quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to improve the tradeoff b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02220-x

    authors: Chen XJ,Luo CH,Chen MH

    更新日期:2020-09-01 00:00:00

  • Computerised volumetric analysis of lesions in multiple sclerosis using new semi-automatic segmentation software.

    abstract::The paper describes the application of new semi-automatic segmentation software to the task of detection of anatomical structures and lesion and their three-dimensional (3D) visualisation in 23 patients with secondary progressive multiple sclerosis (MS). The purpose is to study the correlation between magnetic resonan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513274

    authors: Dastidar P,Heinonen T,Vahvelainen T,Elovaara I,Eskola H

    更新日期:1999-01-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • Prediction of persistence of combined evidence-based cardiovascular medications in patients with acute coronary syndrome after hospital discharge using neural networks.

    abstract::In the PREVENIR-5 study, artificial neural networks (NN) were applied to a large sample of patients with recent first acute coronary syndrome (ACS) to identify determinants of persistence of evidence-based cardiovascular medications (EBCM: antithrombotic + beta-blocker + statin + angiotensin converting enzyme inhibito...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0785-4

    authors: Bourdès V,Ferrières J,Amar J,Amelineau E,Bonnevay S,Berlion M,Danchin N

    更新日期:2011-08-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • Determining appropriate models for joint control using surface electrical stimulation of soleus in spinal cord injury.

    abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512522

    authors: Flaherty B,Robinson C,Agarwal G

    更新日期:1994-05-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00