Abstract:
:A building block-based software framework was developed to simulate electrophysiological networks. The synaptic potentials generated during neurotransmission were simulated in an existing discrete bidomain model of smooth muscle, using cubic, three-dimensional grids of varying sizes. The model is automatically derived and numerically solved, and the results of the simulation agree with previous results obtained analytically. An enhanced model was also proposed, incorporating an additional (junctional) capacitance in the network. The correctness of the model was verified, and the effect of the extra capacitance on the synaptic potentials was explored. It was found that, with a junctional capacitance C(i) of 1.4 x 10(-10) F incorporated, the peak amplitude of the spontaneous excitatory junction potential V(peak) declined by approximately 13% at node 0 and by approximately 37% at node 3x for a system size of 9(3). Similar results were obtained for different system sizes. V(peak) also declined as the junctional capacitance Ci was increased. In a system of size 11(30, a 200-fold increase in C(i) induced a 55% reduction at node 0. It is suggested that the type of modular simulation framework developed here may find general applicability for simulations of other physiological systems.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Turale N,Devulapalli A,Manchanda R,Moudgalya K,Sivakumar Gdoi
10.1007/BF02345322keywords:
subject
Has Abstractpub_date
2003-09-01 00:00:00pages
589-94issue
5eissn
0140-0118issn
1741-0444journal_volume
41pub_type
杂志文章abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348124
更新日期:2002-03-01 00:00:00
abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1107-9
更新日期:2013-12-01 00:00:00
abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347697
更新日期:2002-01-01 00:00:00
abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02045-3
更新日期:2019-12-01 00:00:00
abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344783
更新日期:2000-03-01 00:00:00
abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0483-7
更新日期:2009-05-01 00:00:00
abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1182-6
更新日期:2016-03-01 00:00:00
abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02347706
更新日期:2002-01-01 00:00:00
abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-012-1001-x
更新日期:2013-03-01 00:00:00
abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522869
更新日期:1998-01-01 00:00:00
abstract::A method for making a current-ratio map to determine the ischaemic area of angina pectoris (AP) patients has been developed. This method uses a current-arrow map calculated using a ORS wave from 64-channel magnetocardiogram (MCG) signals. The current-ratio map can be calculated from the ratio of an exercise-induced cu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345263
更新日期:2001-01-01 00:00:00
abstract::The alpha angle is a parameter extensively used to assess for cam-type femoroacetabular impingement (FAI) in a 2D image of the hip. As this angle requires estimation of the axis of the femoral neck, the drawing of this axis often results in measurement errors due to subjective judgment, influencing inter-rater and int...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01973-4
更新日期:2019-07-01 00:00:00
abstract::Mammography is a widely used screening tool and is the gold standard for the early detection of breast cancer. The classification of breast masses into the benign and malignant categories is an important problem in the area of computer-aided diagnosis of breast cancer. A small dataset of 57 breast mass images, each wi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0077-6
更新日期:2006-08-01 00:00:00
abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0886-8
更新日期:2012-05-01 00:00:00
abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441676
更新日期:1990-01-01 00:00:00
abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345448
更新日期:2002-09-01 00:00:00
abstract::Four ventricular fibrillation (VF) detection techniques were assessed using recordings of VF to evaluate sensitivity and VF-like recordings to evaluate specificity. The recordings were obtained from Coronary Care Unit patients. The techniques were: threshold crossing intervals (TCI); peaks in the autocorrelation funct...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446668
更新日期:1993-03-01 00:00:00
abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1081-2
更新日期:2014-03-01 00:00:00
abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0694-y
更新日期:2011-01-01 00:00:00
abstract::Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing r...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02524436
更新日期:1998-09-01 00:00:00
abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02115-6
更新日期:2020-03-01 00:00:00
abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-016-1572-z
更新日期:2017-06-01 00:00:00
abstract::In the PREVENIR-5 study, artificial neural networks (NN) were applied to a large sample of patients with recent first acute coronary syndrome (ACS) to identify determinants of persistence of evidence-based cardiovascular medications (EBCM: antithrombotic + beta-blocker + statin + angiotensin converting enzyme inhibito...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0785-4
更新日期:2011-08-01 00:00:00
abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523019
更新日期:1995-11-01 00:00:00
abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02024-8
更新日期:2019-10-01 00:00:00
abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351041
更新日期:2005-09-01 00:00:00
abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1374-8
更新日期:2016-05-01 00:00:00
abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0394-z
更新日期:2009-01-01 00:00:00
abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345809
更新日期:2005-05-01 00:00:00
abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351008
更新日期:2004-01-01 00:00:00