Simulation framework for electrophysiological networks: effect of syncytial properties on smooth-muscle synaptic potentials.

Abstract:

:A building block-based software framework was developed to simulate electrophysiological networks. The synaptic potentials generated during neurotransmission were simulated in an existing discrete bidomain model of smooth muscle, using cubic, three-dimensional grids of varying sizes. The model is automatically derived and numerically solved, and the results of the simulation agree with previous results obtained analytically. An enhanced model was also proposed, incorporating an additional (junctional) capacitance in the network. The correctness of the model was verified, and the effect of the extra capacitance on the synaptic potentials was explored. It was found that, with a junctional capacitance C(i) of 1.4 x 10(-10) F incorporated, the peak amplitude of the spontaneous excitatory junction potential V(peak) declined by approximately 13% at node 0 and by approximately 37% at node 3x for a system size of 9(3). Similar results were obtained for different system sizes. V(peak) also declined as the junctional capacitance Ci was increased. In a system of size 11(30, a 200-fold increase in C(i) induced a 55% reduction at node 0. It is suggested that the type of modular simulation framework developed here may find general applicability for simulations of other physiological systems.

journal_name

Med Biol Eng Comput

authors

Turale N,Devulapalli A,Manchanda R,Moudgalya K,Sivakumar G

doi

10.1007/BF02345322

keywords:

subject

Has Abstract

pub_date

2003-09-01 00:00:00

pages

589-94

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

41

pub_type

杂志文章
  • Dynamic simulation of the natural and replaced human ankle joint.

    abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348124

    authors: Leardini A,Moschella D

    更新日期:2002-03-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00

  • Prediction of apoptosis protein subcellular location based on position-specific scoring matrix and isometric mapping algorithm.

    abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02045-3

    authors: Ruan X,Zhou D,Nie R,Hou R,Cao Z

    更新日期:2019-12-01 00:00:00

  • French legal framework relating to human tissues and cells.

    abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344783

    authors: Pascal P,Damour O,Colpart JJ,Braye F

    更新日期:2000-03-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.

    abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1182-6

    authors: Jeon M,Kim J,Kim C

    更新日期:2016-03-01 00:00:00

  • Pain model and fuzzy logic patient-controlled analgesia in shock-wave lithotripsy.

    abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02347706

    authors: Shieh JS,Chang LW,Wang MS,Sun WZ,Wang YP,Yang YP

    更新日期:2002-01-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

    abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522869

    authors: Kataoka N,Ujita S,Sato M

    更新日期:1998-01-01 00:00:00

  • A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram.

    abstract::A method for making a current-ratio map to determine the ischaemic area of angina pectoris (AP) patients has been developed. This method uses a current-arrow map calculated using a ORS wave from 64-channel magnetocardiogram (MCG) signals. The current-ratio map can be calculated from the ratio of an exercise-induced cu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345263

    authors: Kandori A,Kanzaki H,Miyatake K,Hashimoto S,Itoh S,Tanaka N,Miyashita T,Tsukada K

    更新日期:2001-01-01 00:00:00

  • Using a numerical method to precisely evaluate the alpha angle in a hip image.

    abstract::The alpha angle is a parameter extensively used to assess for cam-type femoroacetabular impingement (FAI) in a 2D image of the hip. As this angle requires estimation of the axis of the femoral neck, the drawing of this axis often results in measurement errors due to subjective judgment, influencing inter-rater and int...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01973-4

    authors: Lai CL,Chi WM,Ho YJ,Lin CC,Lin HC,Kuo CL,Chen JH

    更新日期:2019-07-01 00:00:00

  • Classification of breast masses in mammograms using genetic programming and feature selection.

    abstract::Mammography is a widely used screening tool and is the gold standard for the early detection of breast cancer. The classification of breast masses into the benign and malignant categories is an important problem in the area of computer-aided diagnosis of breast cancer. A small dataset of 57 breast mass images, each wi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0077-6

    authors: Nandi RJ,Nandi AK,Rangayyan RM,Scutt D

    更新日期:2006-08-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Pressures generated by rib cage and abdominal compressions during cardiopulmonary resuscitation.

    abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441676

    authors: Ben-Haim SA,Shofti R,Dinnar U,Saidel GM

    更新日期:1990-01-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Comparison of four techniques for recognition of ventricular fibrillation from the surface ECG.

    abstract::Four ventricular fibrillation (VF) detection techniques were assessed using recordings of VF to evaluate sensitivity and VF-like recordings to evaluate specificity. The recordings were obtained from Coronary Care Unit patients. The techniques were: threshold crossing intervals (TCI); peaks in the autocorrelation funct...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446668

    authors: Clayton RH,Murray A,Campbell RW

    更新日期:1993-03-01 00:00:00

  • Empirical quantification of internal and external rotation muscular co-activation ratios in healthy shoulders.

    abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1081-2

    authors: Brookham RL,Dickerson CR

    更新日期:2014-03-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy.

    abstract::Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing r...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524436

    authors: Buitenweg JR,Rutten WL,Willems WP,van Nieuwkasteele JW

    更新日期:1998-09-01 00:00:00

  • A new method for measurement of motor unit action potential duration based on correlation, a pilot study.

    abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02115-6

    authors: Rodríguez Carreño I,Malanda A,Gila Useros L,Gurtubay IG,Navallas J,Rodríguez-Falces J

    更新日期:2020-03-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • Prediction of persistence of combined evidence-based cardiovascular medications in patients with acute coronary syndrome after hospital discharge using neural networks.

    abstract::In the PREVENIR-5 study, artificial neural networks (NN) were applied to a large sample of patients with recent first acute coronary syndrome (ACS) to identify determinants of persistence of evidence-based cardiovascular medications (EBCM: antithrombotic + beta-blocker + statin + angiotensin converting enzyme inhibito...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0785-4

    authors: Bourdès V,Ferrières J,Amar J,Amelineau E,Bonnevay S,Berlion M,Danchin N

    更新日期:2011-08-01 00:00:00

  • ANN compression of morphologically similar ECG complexes.

    abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523019

    authors: Hamilton DJ,Thomson DC,Sandham WA

    更新日期:1995-11-01 00:00:00

  • A cepstrum analysis-based classification method for hand movement surface EMG signals.

    abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02024-8

    authors: Yavuz E,Eyupoglu C

    更新日期:2019-10-01 00:00:00

  • CT-3D rotational angiography automatic registration: a sensitivity analysis.

    abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351041

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Causin F,Colombo F

    更新日期:2005-09-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

    abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0394-z

    authors: Jaffrin MY,Morel H

    更新日期:2009-01-01 00:00:00

  • Urinary bladder volume tracking using a Kalman filter.

    abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345809

    authors: Kristiansen NK,Sjöström SO,Nygaard H

    更新日期:2005-05-01 00:00:00

  • Investigating body motion patterns in patients with Parkinson's disease using matching pursuit algorithm.

    abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351008

    authors: Sekine M,Akay M,Tamura T,Higashi Y,Fujimoto T

    更新日期:2004-01-01 00:00:00