Abstract:
:Four ventricular fibrillation (VF) detection techniques were assessed using recordings of VF to evaluate sensitivity and VF-like recordings to evaluate specificity. The recordings were obtained from Coronary Care Unit patients. The techniques were: threshold crossing intervals (TCI); peaks in the autocorrelation function (ACF); signal content outside the mean frequency (VF-filter); and signal spectrum shape (spectrum). Using 70 extracts, each 4 s long, from VF recordings, the VF filter achieved a sensitivity of 77 per cent; the ACF, TCI and spectrum algorithms had sensitivities of 67, 53 and 46 per cent, respectively. Susceptibility to false alarms was assessed using 40 extracts from VF-like recordings. The TCI algorithm was the most specific (93 per cent), while the spectrum, VF filter and ACF algorithms had specificities of 72, 55 and 38 per cent, respectively. The TCI algorithm achieved overall sensitivity of 93 per cent and specificity of 60 per cent. The spectrum, VF filter and ACF algorithms had overall sensitivities of 80, 93 and 87 per cent, and overall specificities of 60, 20 and 0 per cent, respectively.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Clayton RH,Murray A,Campbell RWdoi
10.1007/BF02446668subject
Has Abstractpub_date
1993-03-01 00:00:00pages
111-7issue
2eissn
0140-0118issn
1741-0444journal_volume
31pub_type
杂志文章abstract::Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1359-7
更新日期:2016-04-01 00:00:00
abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02518872
更新日期:1998-11-01 00:00:00
abstract::Most tissues are subject to some form of physiological mechanical loading which results in deformation of the cells triggering intracellular mechanotransduction pathways. This response to loading is generally essential for the health of the tissue, although more pronounced deformation may result in cell and tissue dam...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-008-0381-4
更新日期:2008-10-01 00:00:00
abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02024-8
更新日期:2019-10-01 00:00:00
abstract::Architectural distortion is a subtle abnormality in mammograms, and a source of overlooking errors by radiologists. Computer-aided diagnosis (CAD) techniques can improve the performance of radiologists in detecting masses and calcifications; however, most CAD systems have not been designed to detect architectural dist...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0088-3
更新日期:2006-10-01 00:00:00
abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441486
更新日期:1989-05-01 00:00:00
abstract::On the basis of spatial covariance it is found that, by spatial filtering the localisation of a single dipole source, both parallel and perpendicular to the measurement plane (assuming a signal-noise ratio of 5:1), can be performed with an accuracy of < 0.5 mm. When the signal-noise ratio is increased to 30:1, the res...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510982
更新日期:1997-11-01 00:00:00
abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348124
更新日期:2002-03-01 00:00:00
abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522517
更新日期:1995-07-01 00:00:00
abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02525536
更新日期:1997-09-01 00:00:00
abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347697
更新日期:2002-01-01 00:00:00
abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0939-z
更新日期:2012-09-01 00:00:00
abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348134
更新日期:2002-03-01 00:00:00
abstract::The vagus nerves convey both afferent and efferent information about autonomic activity related to cardiovascular functions. Those functions have been shown to change due to epileptic seizures, which suggests that ictal events might be detected via the vagus electroneurogram (VENG). In this study, we characterize the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0782-7
更新日期:2011-09-01 00:00:00
abstract::Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly diffe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441986
更新日期:1993-09-01 00:00:00
abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510536
更新日期:1995-05-01 00:00:00
abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0716-9
更新日期:2011-01-01 00:00:00
abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0117-2
更新日期:2006-11-01 00:00:00
abstract::Automatic identification of landmarks in cephalometry is very important and useful for orthognathic surgery. A computerised automatic cephalometric analysis system (CACAS), based on image processing, is presented. For an original X-ray image, median filtering and histogram equalisation are used to improve image qualit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345280
更新日期:2001-05-01 00:00:00
abstract::Recent studies were investigated that report spontaneous oscillations of cerebral perfusion in the very low-frequency range (0.01-0.04 Hz), emphasising details of spectral estimation. The effects of different spectral estimation procedures were compared, using simulated and clinical data. It was shown that data detren...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02343541
更新日期:2003-01-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00
abstract::A simple objective screening method for diagnosis of the atrial septal defect (ASD) is needed. Acoustic signals were collected from 61 children with ASD and 60 with a physiological murmur. The second heart sound (S2) and the spectrum of systolic murmur were analysed. A statistical model was designed using stepwise log...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0094-5
更新日期:2006-09-01 00:00:00
abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02515312
更新日期:1994-09-01 00:00:00
abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345967
更新日期:2005-03-01 00:00:00
abstract::Increasing costs in healthcare have stimulated discussions on whether installation of competent in-house service groups for equipment management could eventually aid in reducing expenditure. In the Federal Republic of Germany, a four-year programme was initiated in 1979 with the purpose of investigating the feasibilit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02442172
更新日期:1989-01-01 00:00:00
abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02076-w
更新日期:2020-01-01 00:00:00
abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510972
更新日期:1997-11-01 00:00:00
abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0043-3
更新日期:2006-05-01 00:00:00
abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344215
更新日期:2002-05-01 00:00:00
abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1752-5
更新日期:2018-06-01 00:00:00