Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis.

Abstract:

:Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacity to detect newborn acidemia. MHR and FHR were simultaneously recorded in 51 singleton term pregnancies during the last two hours of labor and compared with newborn umbilical artery blood (UAB) pH. Linear/nonlinear indices were computed separately for MHR and FHR. Interaction between MHR and FHR was quantified through the same indices on FHR-MHR and through their correlation and cross-entropy. Univariate and bivariate statistical analysis included nonparametric confidence intervals and statistical tests, receiver operating characteristic curves and linear discriminant analysis. Progression of labor was associated with a significant increase in most MHR and FHR linear indices, whereas entropy indices decreased. FHR alone and in combination with MHR as FHR-MHR evidenced the highest auROC values for prediction of fetal acidemia, with 0.76 and 0.88 for the UAB pH thresholds 7.20 and 7.15, respectively. The inclusion of MHR on bivariate analysis achieved sensitivity and specificity values of nearly 100 and 89.1%, respectively. These results suggest that simultaneous analysis of MHR and FHR may improve the identification of fetal acidemia compared with FHR alone, namely during the last hour of labor.

journal_name

Med Biol Eng Comput

authors

Gonçalves H,Pinto P,Silva M,Ayres-de-Campos D,Bernardes J

doi

10.1007/s11517-015-1359-7

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

691-9

issue

4

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-015-1359-7

journal_volume

54

pub_type

杂志文章
  • Corrected formula for estimating peripheral blood flow by impedance plethysmography.

    abstract::In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524237

    authors: Jindal GD,Nerurkar SN,Pednekar SA,Babu JP,Bhuta AC,Deshpande AK

    更新日期:1994-11-01 00:00:00

  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • New method using multi-regression analysis on evoked electromyography during movement to adjust stimulation conditions.

    abstract::A new method of stimulation of the lower extremities was devised that automatically adjusts the stimulation conditions at any angle of the knee joint. An M-wave is considered to indicate the stimulation conditions, because it is the waveform that results from direct stimulation to the axon of the alpha motor neuron. T...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351018

    authors: Tanabe S,Muraoka Y,Tomita Y

    更新日期:2004-01-01 00:00:00

  • Cardiac anisotropy in boundary-element models for the electrocardiogram.

    abstract::The boundary-element method (BEM) is widely used for electrocardiogram (ECG) simulation. Its major disadvantage is its perceived inability to deal with the anisotropic electric conductivity of the myocardial interstitium, which led researchers to represent only intracellular anisotropy or neglect anisotropy altogether...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0472-x

    authors: Potse M,Dubé B,Vinet A

    更新日期:2009-07-01 00:00:00

  • Delivery devices for exposure of biological cells to nanosecond pulsed electric fields.

    abstract::In this paper, delivery devices for nanosecond pulsed electric field exposure of biological samples in direct contact with electrodes or isolated are presented and characterized. They are based on a modified electroporation cuvette and two transverse electromagnetic cells (TEM cells). The devices were used to apply pu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1676-0

    authors: Soueid M,Dobbelaar MCF,Bentouati S,Bardet SM,O'Connor RP,Bessières D,Paillol J,Leveque P,Arnaud-Cormos D

    更新日期:2018-01-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

    abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02101-y

    authors: Ilhan HO,Sigirci IO,Serbes G,Aydin N

    更新日期:2020-05-01 00:00:00

  • Finite element analysis of brain contusion: an indirect impact study.

    abstract::The mechanism of brain contusion has been investigated using a series of three-dimensional (3D) finite element analyses. A head injury model was used to simulate forward and backward rotation around the upper cervical vertebra. Intracranial pressure and shear stress responses were calculated and compared. The results ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347044

    authors: Huang HM,Lee MC,Lee SY,Chiu WT,Pan LC,Chen CT

    更新日期:2000-05-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

    abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534088

    authors: Kamath MV,Tougas G,Hollerbach S,Premji R,Fitzpatrick D,Shine G,Upton AR

    更新日期:1997-07-01 00:00:00

  • Sub-threshold depolarizing pre-pulses can enhance the efficiency of biphasic stimuli in transcutaneous neuromuscular electrical stimulation.

    abstract::There is multiple evidence in the literature that a sub-threshold pre-pulse, delivered immediately prior to an electrical stimulation pulse, can alter the activation threshold of nerve fibers and motor unit recruitment characteristics. So far, previously published works combined monophasic stimuli with sub-threshold d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1851-y

    authors: Vargas Luna JL,Mayr W,Cortés-Ramirez JA

    更新日期:2018-12-01 00:00:00

  • Proposal of hemodynamically improved design of an axial flow blood pump for LVAD.

    abstract::Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02097-5

    authors: Kannojiya V,Das AK,Das PK

    更新日期:2020-02-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Atrial septal defect: a diagnostic approach.

    abstract::A simple objective screening method for diagnosis of the atrial septal defect (ASD) is needed. Acoustic signals were collected from 61 children with ASD and 60 with a physiological murmur. The second heart sound (S2) and the spectrum of systolic murmur were analysed. A statistical model was designed using stepwise log...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0094-5

    authors: El-Segaier M,Pesonen E,Lukkarinen S,Peters K,Ingemansson J,Sörnmo L,Sepponen R

    更新日期:2006-09-01 00:00:00

  • Continuous cardiac output monitoring system.

    abstract::A continuous cardiac output monitoring system has been developed in the laboratory to allow the real-time measurement of the cardiac output. This form of continuous cardiac output measurement allows the doctor to view the beat-to-beat cardiac output and can be employed to measure artery constrictions as well. The sens...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345272

    authors: Tjin SC,Ho YC,Lam YZ,Hao J,Ng BK

    更新日期:2001-01-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Modelling the effect of insulin on the disposal of meal-attributable glucose in type 1 diabetes.

    abstract::The management of postprandial glucose excursions in type 1 diabetes has a major impact on overall glycaemic control. In this work, we propose and evaluate various mechanistic models to characterize the disposal of meal-attributable glucose. Sixteen young volunteers with type 1 diabetes were subject to a variable-targ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1509-6

    authors: García-García F,Hovorka R,Wilinska ME,Elleri D,Hernando ME

    更新日期:2017-02-01 00:00:00

  • Detailed quantitative assessment of colonic morphology at CT colonography using novel software: a feasibility and reproducibility study.

    abstract::The aim of this study was to evaluate feasibility and reproducibility of quantitative assessment of colonic morphology on CT colonography (CTC). CTC datasets from 60 patients with optimal colonic distension were assessed using prototype software. Metrics potentially associated with poor endoscopic performance were cal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1529-2

    authors: Weber CN,Lev-Toaff AS,Levine MS,Sudarsky S,Guendel L,Geiger B,Zafar HM

    更新日期:2017-03-01 00:00:00

  • A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram.

    abstract::A method for making a current-ratio map to determine the ischaemic area of angina pectoris (AP) patients has been developed. This method uses a current-arrow map calculated using a ORS wave from 64-channel magnetocardiogram (MCG) signals. The current-ratio map can be calculated from the ratio of an exercise-induced cu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345263

    authors: Kandori A,Kanzaki H,Miyatake K,Hashimoto S,Itoh S,Tanaka N,Miyashita T,Tsukada K

    更新日期:2001-01-01 00:00:00

  • Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability.

    abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344729

    authors: Lange S,Van Leeuwen P,Geue D,Hatzmann W,Grönemeyer D

    更新日期:2005-07-01 00:00:00

  • CFD simulations for paper-based DNA amplification reaction (LAMP) of Mycobacterium tuberculosis-point-of-care diagnostic perspective.

    abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02082-y

    authors: Das D,Panigrahi PK

    更新日期:2020-02-01 00:00:00

  • A machine learning approach for magnetic resonance image-based mouse brain modeling and fast computation in controlled cortical impact.

    abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02262-1

    authors: Lai C,Chen Y,Wang T,Liu J,Wang Q,Du Y,Feng Y

    更新日期:2020-11-01 00:00:00

  • Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

    abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522869

    authors: Kataoka N,Ujita S,Sato M

    更新日期:1998-01-01 00:00:00

  • Relationship between stimulus amplitude, stimulus frequency and neural damage during electrical stimulation of sciatic nerve of cat.

    abstract::The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510526

    authors: McCreery DB,Agnew WF,Yuen TG,Bullara LA

    更新日期:1995-05-01 00:00:00

  • Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

    abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349982

    authors: Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

    更新日期:2003-11-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Real time monitoring and analysis via the medical information bus, Part II.

    abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525536

    authors: Taboada JA,Arcay B,Arias JE

    更新日期:1997-09-01 00:00:00

  • Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study.

    abstract::A computer-aided method was developed to automatically localize tumors in lung PET images of discrete bins within the breathing cycle, followed by an algorithm that registers all the information of a complete respiratory cycle into a single reference bin. Four registration/integration algorithms: Centroid Based, Inten...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0549-6

    authors: Wang J,del Valle M,Goryawala M,Franquiz JM,McGoron AJ

    更新日期:2010-01-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00