Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

Abstract:

:The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed for (i) one-way flow, (ii) reciprocating flow with a 30 min interval and (iii) alternating orthogonal flows with a 30 min interval. After flow exposure, the endothelial cells were fixed and F-actin filaments were stained with rhodamine phalloidin. Endothelial cells were observed and photographed by means of a microscope equipped with epifluorescence optics. The shape index (SI) and angle of cell orientation were measured, and F-actin distributions in the cells were statistically studied. Endothelial cells under the one-way flow condition showed marked elongation (SI = 0.39 +/- 0.16, mean +/- S.D.) and aligned with the flow direction. In the case of the reciprocating (SI = 0.63 +/- 0.14) and the alternating orthogonal flows (0.64 +/- 0.14), cells did not elongate so strongly as in the case of one-way flow. Although most cells in the reciprocating flow aligned with the flow direction, the cell axes in the alternate orthogonal flow distributed around a mean value of -45.1 degrees with a large S.D. value. Endothelial cells can be expected to recognise the flow direction, and change their shape and F-actin structure.

journal_name

Med Biol Eng Comput

authors

Kataoka N,Ujita S,Sato M

doi

10.1007/BF02522869

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

122-8

issue

1

eissn

0140-0118

issn

1741-0444

journal_volume

36

pub_type

杂志文章
  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00

  • Silicone rubber encapsulation for an endoscopically implantable gastrostimulator.

    abstract::Gastrointestinal stimulator implants have recently shown positive results in treating obesity. However, the implantation currently requires an invasive surgical procedure. Endoscopy could be used to place the gastric stimulator in the stomach, hence avoiding the riskier surgery. The implant then needs to go through th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1236-9

    authors: Lonys L,Vanhoestenberghe A,Julémont N,Godet S,Delplancke MP,Mathys P,Nonclercq A

    更新日期:2015-04-01 00:00:00

  • Mechanisms governing the visco-elastic responses of living cells assessed by foam and tensegrity models.

    abstract::The visco-elastic properties of living cells, measured to date by various authors, vary considerably, depending on the experimental methods and/or on the theoretical models used. In the present study, two mechanisms thought to be involved in cellular visco-elastic responses were analysed, based on the idea that the cy...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349982

    authors: Cañadas P,Laurent VM,Chabrand P,Isabey D,Wendling-Mansuy S

    更新日期:2003-11-01 00:00:00

  • Young and advanced tumor-some 2D electrodynamic distinctions: melanoma and satellite during a vascular occlusion test: feasibility study.

    abstract::Conventional methods of electrobioimpedance imaging are not suited for adequate visualization of the skin electrical impedance landscape (SEL) because they do not provide high spatial resolution at large enough area of view. The skin electrodynamics introscopy (SEI) enabled dynamic spectral imaging of the SEL at 32 × ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1668-0

    authors: Babich Y,Nuzhdina M,Syniuta S

    更新日期:2018-02-01 00:00:00

  • Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

    abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0741-3

    authors: Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau A

    更新日期:2011-04-01 00:00:00

  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect.

    abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345312

    authors: Han BH,Lee SY,Kim JH,Yi JH

    更新日期:2003-09-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

    abstract::The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (P...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0621-2

    authors: Kim HJ,Chun HJ,Moon SH,Kang KT,Kim HS,Park JO,Moon ES,Sohn JS,Lee HM

    更新日期:2010-07-01 00:00:00

  • Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations.

    abstract::The object of this study is to compare the performance of two new bilinear time-frequency representation techniques with the spectrogram to characterise the behaviour of heart murmurs produced by bioprosthetic heart valves implanted in the mitral or aortic position. The murmurs are those of mitral stenosis, mitral reg...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02525526

    authors: Debiais F,Durand LG,Pibarot P,Guardo R

    更新日期:1997-09-01 00:00:00

  • Hybrid finite elements and spectral method for computation of the electric potential generated by a nerve cuff electrode.

    abstract::An original numerical method is developed to compute the 3D electric potential generated by a dot-contact cuff electrode implanted around an axisymmetrical, inhomogeneous, anisotropic nerve. The technique is based on a 2D finite-element approach coupled with a semi-analytical Fourier spectral decomposition to approxim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513375

    authors: Parrini S,Delbeke J,Romero E,Legat V,Veraart C

    更新日期:1999-11-01 00:00:00

  • Application of artificial neural network model combined with four biomarkers in auxiliary diagnosis of lung cancer.

    abstract::The purpose of the study was to explore the application of artificial neural network model in the auxiliary diagnosis of lung cancer and compare the effects of back-propagation (BP) neural network with Fisher discrimination model for lung cancer screening by the combined detections of four biomarkers of p16, RASSF1A a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1585-7

    authors: Duan X,Yang Y,Tan S,Wang S,Feng X,Cui L,Feng F,Yu S,Wang W,Wu Y

    更新日期:2017-08-01 00:00:00

  • Myocardial mechanics and the Fenn effect determined from a cardiac muscle crossbridge model.

    abstract::A three-element cardiac muscle fibre model, utilising Huxley's sliding filament theory for the contractile element and coupled with parallel and series elastic components, was simulated to see if it were possible to predict the cardiac Fenn effect. The force/length energy (FLE) was computed in both isometric and isoto...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446691

    authors: Taylor TW,Goto Y,Suga H

    更新日期:1993-07-01 00:00:00

  • Wireless and inductively powered implant for measuring electrocardiogram.

    abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-007-0264-0

    authors: Riistama J,Väisänen J,Heinisuo S,Harjunpää H,Arra S,Kokko K,Mäntylä M,Kaihilahti J,Heino P,Kellomäki M,Vainio O,Vanhala J,Lekkala J,Hyttinen J

    更新日期:2007-12-01 00:00:00

  • A novel fused convolutional neural network for biomedical image classification.

    abstract::With the advent of biomedical imaging technology, the number of captured and stored biomedical images is rapidly increasing day by day in hospitals, imaging laboratories and biomedical institutions. Therefore, more robust biomedical image analysis technology is needed to meet the requirement of the diagnosis and class...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1819-y

    authors: Pang S,Du A,Orgun MA,Yu Z

    更新日期:2019-01-01 00:00:00

  • Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibility.

    abstract::Cerebral autoregulation controls cerebral blood flow under changing cerebral perfusion pressure. Standards for measurement and analysis of dynamic cerebral autoregulation (dCA) are lacking. In this study, dCA reproducibility, quantified by intraclass correlation coefficient, is evaluated for different methodological a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0706-y

    authors: Gommer ED,Shijaku E,Mess WH,Reulen JP

    更新日期:2010-12-01 00:00:00

  • A comparison of two Hilbert spectral analyses of heart rate variability.

    abstract::The present paper compares the performance of two Hilbert spectral analyses when applied to a synthetic RR series from a nonstationary integral pulse frequency modulation model and to real RR series from a dataset of normal sinus arrhythmia. The Hilbert-Huang transformation based on empirical mode decomposition is com...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0500-x

    authors: Ihlen EA

    更新日期:2009-10-01 00:00:00

  • Spectral analysis of heart rate variability using the integral pulse frequency modulation model.

    abstract::Spectral analysis of heart rate variability (HRV) is a widely accepted approach for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. As a rule, the non-parametric methods for HRV spectral analysis are tested using the integral pulse frequency modulation (IPFM) model. Ho...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345290

    authors: Mitov IP

    更新日期:2001-05-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Neural oscillators triggered by loading and hip orientation can generate activation patterns at the ankle during walking in humans.

    abstract::Spinal pattern generators (SPGs), which are neural networks without a central input from the brain may be responsible for controlling locomotion. In this study, we used neural oscillators to examine the rhythmic patterns generated at the ankle during walking. Seven healthy male subjects were requested to walk at their...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0944-2

    authors: Chong SY,Wagner H,Wulf A

    更新日期:2012-09-01 00:00:00

  • Clinical applications of musculoskeletal modelling for the shoulder and upper limb.

    abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-013-1099-5

    authors: Bolsterlee B,Veeger DH,Chadwick EK

    更新日期:2013-09-01 00:00:00

  • Hip implant performance prediction by acoustic emission techniques: a review.

    abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02202-z

    authors: Remya AR,Vishwash B,Lee C,Pai PS,Espinoza Oras AA,Ozevin D,Mathew MT

    更新日期:2020-08-01 00:00:00

  • Evaluation of feature extraction techniques and classifiers for finger movement recognition using surface electromyography signal.

    abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1857-5

    authors: Phukpattaranont P,Thongpanja S,Anam K,Al-Jumaily A,Limsakul C

    更新日期:2018-12-01 00:00:00

  • Elastic porous tube model of reactive hyperaemia.

    abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02515312

    authors: Smye SW,Bloor MI

    更新日期:1994-09-01 00:00:00

  • Electrotactile perception of scatterplots on the fingertips and abdomen.

    abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345967

    authors: Haase SJ,Kaczmarek KA

    更新日期:2005-03-01 00:00:00

  • Identification of the breast boundary in mammograms using active contour models.

    abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344632

    authors: Ferrari RJ,Rangayyan RM,Desautels JE,Borges RA,Frère AF

    更新日期:2004-03-01 00:00:00

  • Clinical evaluation of 430 MHz microwave hyperthermia system with lens applicator for cancer therapy.

    abstract::The clinical efficacy of a microwave (MW) hyperthermia system using an electric-field converging (lens) applicator is evaluated for 42 malignant tumours with a maximum tumour depth of less than 7 cm. The mean of the maximum, average and minimum tumour temperature of the 42 tumours are 44.5, 42.5 and 40.7 C, respective...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02522944

    authors: Hiraoka M,Nishimura Y,Masunaga S,Koishi M,Mitsumori M,Li YP,Nagata Y,Akuta K,Takahashi M,Abe M

    更新日期:1995-01-01 00:00:00

  • Performance analysis of melanoma classifier using electrical modeling technique.

    abstract::An efficient and novel modeling approach is proposed in this paper for identifying proteins or genes involved in melanoma skin cancer. Two types of classifiers are modeled, based on the chemical structure and hydropathy property of amino acids. These classifiers are further implemented using NI LabVIEW-based hardware ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02241-6

    authors: Roy T,Bhattacharjee P

    更新日期:2020-10-01 00:00:00

  • A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0348-5

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-07-01 00:00:00

  • Quantitative measurement of Parkinsonian gait from walking in monocular image sequences using a centroid tracking algorithm.

    abstract::Parkinson's disease (PD) is a neurodegenerative disease of the central nervous system that results from the degeneration of dopaminergic neurons in the substantia nigra. Abnormal gait begins in the early stage and becomes severe as the disease progresses; therefore, the assessment of gait becomes an important issue in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1335-2

    authors: Lin SH,Chen SW,Lo YC,Lai HY,Yang CH,Chen SY,Chang YJ,Chen CH,Huang WT,Jaw FS,Chen YY,Tsang S,Liao LD

    更新日期:2016-03-01 00:00:00