Silicone rubber encapsulation for an endoscopically implantable gastrostimulator.

Abstract:

:Gastrointestinal stimulator implants have recently shown positive results in treating obesity. However, the implantation currently requires an invasive surgical procedure. Endoscopy could be used to place the gastric stimulator in the stomach, hence avoiding the riskier surgery. The implant then needs to go through the oesophagus and be located inside the stomach, which imposes new design constraints, such as miniaturization and protecting the electronic circuit against the highly acidic environment of the stomach. We propose to protect the implant by encapsulation with silicone rubber. This paper lists the advantages of this method compared to the more usual approach of a hermetic enclosure and then presents a method to evaluate the underwater adhesive stability of six adhesive/substrate couples, using repeated lap-shear tests and an elevated temperature to accelerate the ageing process. The results for different adhesive/substrate couples tested, presented on probability plots, show that FR4 and alumina substrates with MED4-4220 silicone rubber are suitable for a first implantable prototype. We then compare these with the predicted lifetimes of bonds between historical standard silicone rubber DC3140 and different substrates and describe the encapsulation of our gastrostimulator.

journal_name

Med Biol Eng Comput

authors

Lonys L,Vanhoestenberghe A,Julémont N,Godet S,Delplancke MP,Mathys P,Nonclercq A

doi

10.1007/s11517-014-1236-9

subject

Has Abstract

pub_date

2015-04-01 00:00:00

pages

319-29

issue

4

eissn

0140-0118

issn

1741-0444

journal_volume

53

pub_type

杂志文章
  • French legal framework relating to human tissues and cells.

    abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344783

    authors: Pascal P,Damour O,Colpart JJ,Braye F

    更新日期:2000-03-01 00:00:00

  • Effective identification and localization of immature precursors in bone marrow biopsy.

    abstract::Abnormal localization of immature precursors (ALIP) aggregating and clustering in bone marrow biopsy appears earlier than that of bone marrow smears in detection of the relapse of acute myelocytic leukemia (AML). But traditional manual ALIP recognition has many shortcomings such as prone to false alarms, neglect of di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1223-1

    authors: Cao G,Li L,Chen W,Yu Y,Shi J,Zhang G,Liu X

    更新日期:2015-03-01 00:00:00

  • A new software scheme for scatter correction based on a simple radiographic scattering model.

    abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1893-1

    authors: Kim K,Kang S,Kim W,Park C,Lee D,Cho H,Kang W,Park S,Kim G,Lim H,Lee H,Park J,Jeon D,Lim Y,Woo T,Oh J

    更新日期:2019-02-01 00:00:00

  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • Analysis and decision based on specialist self-assessment for prognosis factors of acute leukemia integrating data-driven Bayesian network and fuzzy cognitive map.

    abstract::The purpose of the present study is to analyze the prognostic factors of acute leukemia and to construct a decision model based on a causal relationship between the factors of this disease to assist medical specialists. In medical decisions, to reach effective, quick, and reliable results, there is a need for a simple...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02267-w

    authors: Jahangoshai Rezaee M,Sadatpour M,Ghanbari-Ghoushchi N,Fathi E,Alizadeh A

    更新日期:2020-11-01 00:00:00

  • Relation between branching patterns and perfusion in stochastic generated coronary arterial trees.

    abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0139-9

    authors: Dankelman J,Cornelissen AJ,Lagro J,Vanbavel E,Spaan JA

    更新日期:2007-01-01 00:00:00

  • Reexamination of risk criteria in dengue patients using the self-organizing map.

    abstract::Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue pa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0561-x

    authors: Faisal T,Taib MN,Ibrahim F

    更新日期:2010-03-01 00:00:00

  • Development of a comprehensive musculoskeletal model of the shoulder and elbow.

    abstract::The Delft Shoulder and Elbow Model (DSEM), a musculoskeletal model of the shoulder and elbow has been extensively developed since its introduction in 1994. Extensions cover both model structures and anatomical data focusing on the addition of an elbow part and muscle architecture parameters. The model was also extende...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0839-7

    authors: Nikooyan AA,Veeger HE,Chadwick EK,Praagman M,Helm FC

    更新日期:2011-12-01 00:00:00

  • Extraction of Cole parameters from the electrical bioimpedance spectrum using stochastic optimization algorithms.

    abstract::Fitting the measured bioimpedance spectroscopy (BIS) data to the Cole model and then extracting the Cole parameters is a common practice in BIS applications. The extracted Cole parameters then can be analysed as descriptors of tissue electrical properties. To have a better evaluation of physiological or pathological p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1355-y

    authors: Gholami-Boroujeny S,Bolic M

    更新日期:2016-04-01 00:00:00

  • Opportunities for the cellular approach in biomedical engineering.

    abstract::This review is a commentary on recent, altered perspectives about biomedical engineering and its role in medicine. It is argued that, rather than being a peripheral specialty, medical engineering and engineering principles in general have a direct application to biochemical medicine and cell biology. A brief descripti...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02446170

    authors: Vadgama P

    更新日期:1992-07-01 00:00:00

  • Elastic porous tube model of reactive hyperaemia.

    abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02515312

    authors: Smye SW,Bloor MI

    更新日期:1994-09-01 00:00:00

  • Optimal chest compression in cardiopulmonary resuscitation depends upon thoracic and back support stiffness.

    abstract::A biomechanical analysis of the constant peak displacement and constant peak force methods of cardiopulmonary resuscitation (CPR) has revealed that optimal CC performance strongly depends on back support stiffness, CC rate, and the thoracic stiffness of the patient being resuscitated. Clinically the results presented ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0963-z

    authors: Dellimore KH,Scheffer C

    更新日期:2012-12-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

    abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0539-8

    authors: Monaghan CC,van Riel WJ,Veltink PH

    更新日期:2009-11-01 00:00:00

  • Viscoelastic response of human hair cortex.

    abstract::The present study describes a new methodological approach which allows the separate analysis and quantitative determination of the viscous and elastic components of human hair using a computerised experimental system. In a first series of experiments subsequent to the estimation of the cross-sectional surface area of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446198

    authors: Nikiforidis G,Balas C,Tsambaos D

    更新日期:1992-01-01 00:00:00

  • A convolutional neural network-based learning approach to acute lymphoblastic leukaemia detection with automated feature extraction.

    abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02282-x

    authors: Anwar S,Alam A

    更新日期:2020-12-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Electrotactile perception of scatterplots on the fingertips and abdomen.

    abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345967

    authors: Haase SJ,Kaczmarek KA

    更新日期:2005-03-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00

  • Design and application of sensor for recording sounds over human eye and nose.

    abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523031

    authors: Journée HL,van Bruggen AC,van der Meer JJ,de Jonge AB,Mooij JJ

    更新日期:1995-03-01 00:00:00

  • A novel fused convolutional neural network for biomedical image classification.

    abstract::With the advent of biomedical imaging technology, the number of captured and stored biomedical images is rapidly increasing day by day in hospitals, imaging laboratories and biomedical institutions. Therefore, more robust biomedical image analysis technology is needed to meet the requirement of the diagnosis and class...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1819-y

    authors: Pang S,Du A,Orgun MA,Yu Z

    更新日期:2019-01-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • ANN compression of morphologically similar ECG complexes.

    abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523019

    authors: Hamilton DJ,Thomson DC,Sandham WA

    更新日期:1995-11-01 00:00:00

  • Automatic lesion segmentation and classification of hepatic echinococcosis using a multiscale-feature convolutional neural network.

    abstract::Hepatic echinococcosis (HE) is a life-threatening liver disease caused by parasites that requires a precise diagnosis and proper treatments. To assess HE lesions accurately, we propose a novel automatic HE lesion segmentation and classification network that contains lesion region positioning (LRP) and lesion region se...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02126-8

    authors: Xin S,Shi H,Jide A,Zhu M,Ma C,Liao H

    更新日期:2020-03-01 00:00:00

  • Empirical quantification of internal and external rotation muscular co-activation ratios in healthy shoulders.

    abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1081-2

    authors: Brookham RL,Dickerson CR

    更新日期:2014-03-01 00:00:00

  • Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation.

    abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0367-2

    authors: Kim HC,Park HJ,Ham SY,Nam KW,Choi SY,Oh JS,Choi H,Jeong GS,Park SW,Kim MG,Sun K

    更新日期:2008-08-01 00:00:00

  • Backflow length predictions during flow-controlled infusions using a nonlinear biphasic finite element model.

    abstract::A previously proposed finite element model that considers geometric and material nonlinearities and the free boundary problems that occur at the catheter tip and in the annular zone around the lateral surface of the catheter was revised and was used to fit a power-law formula to predict backflow length during infusion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1187-1

    authors: Orozco GA,Smith JH,García JJ

    更新日期:2014-10-01 00:00:00

  • A new combination: scale-space filtering of projected brain activities.

    abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0450-3

    authors: Aydin S

    更新日期:2009-04-01 00:00:00