Backflow length predictions during flow-controlled infusions using a nonlinear biphasic finite element model.

Abstract:

:A previously proposed finite element model that considers geometric and material nonlinearities and the free boundary problems that occur at the catheter tip and in the annular zone around the lateral surface of the catheter was revised and was used to fit a power-law formula to predict backflow length during infusions into brain tissue. Compared to a closed-form solution based on linear elasticity, the power-law formula for compliant materials predicted a substantial lower influence of the shear modulus and catheter radius on the backflow length, whereas the corresponding influence for stiffer materials was more consistent with the closed-form solution. The finite element model predicted decreases of the backflow length for reduction of the shear modulus for highly compliant materials (shear modulus less than 500 Pa) due to the increased area of infusion and the high fluid fraction near the infusion cavity that greatly increased the surface area available for fluid transfer and reduced the hydraulic resistance toward the tissue. These results show the importance of taking into account the material and geometrical nonlinearities that arise near the infusion surface as well as the change of hydraulic conductivity with strain for a proper characterization of backflow length during flow-controlled infusions into the brain.

journal_name

Med Biol Eng Comput

authors

Orozco GA,Smith JH,García JJ

doi

10.1007/s11517-014-1187-1

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

841-9

issue

10

eissn

0140-0118

issn

1741-0444

journal_volume

52

pub_type

杂志文章
  • Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

    abstract::Significant efforts were invested during the last decade to accelerate PET list-mode reconstructions, notably with GPU devices. However, the computation time per event is still relatively long, and the list-mode efficiency on the GPU is well below the histogram-mode efficiency. Since list-mode data are not arranged in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1284-9

    authors: Nassiri MA,Carrier JF,Després P

    更新日期:2015-09-01 00:00:00

  • Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis.

    abstract::This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0349-4

    authors: Dobbe JG,Streekstra GJ,Atasever B,van Zijderveld R,Ince C

    更新日期:2008-07-01 00:00:00

  • Design of a novel mobility device controlled by the feet motion of a standing child: a feasibility study.

    abstract::Self-generated mobility is a major contributor to the physical, emotional, cognitive, and social development of infants and toddlers. When young children have disorders that hinder self locomotion, their development is at risk for delay. Independent mobility via traditional power mobility devices may prevent this dela...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0820-5

    authors: Schoepflin ZR,Chen X,Ragonesi CB,Galloway JC,Agrawal SK

    更新日期:2011-10-01 00:00:00

  • Modelling and numerical simulation of the in vivo mechanical response of the ascending aortic aneurysm in Marfan syndrome.

    abstract::Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1524-7

    authors: García-Herrera CM,Celentano DJ,Herrera EA

    更新日期:2017-03-01 00:00:00

  • Using a numerical method to precisely evaluate the alpha angle in a hip image.

    abstract::The alpha angle is a parameter extensively used to assess for cam-type femoroacetabular impingement (FAI) in a 2D image of the hip. As this angle requires estimation of the axis of the femoral neck, the drawing of this axis often results in measurement errors due to subjective judgment, influencing inter-rater and int...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01973-4

    authors: Lai CL,Chi WM,Ho YJ,Lin CC,Lin HC,Kuo CL,Chen JH

    更新日期:2019-07-01 00:00:00

  • Empirical mode decomposition: a method to reduce low frequency interferences from surface electroenterogram.

    abstract::The surface electroenterogram (EEnG) is a non-invasive method of studying myoelectrical bowel activity. However, surface EEnG recordings are contaminated by cardiac activity, respiratory and motion artifacts, and other sources of interference. The aim of this work is to remove the respiration artifact and the very low...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0189-7

    authors: Ye Y,Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2007-06-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access.

    abstract::Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to ch...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345123

    authors: Mansy HA,Hoxie SJ,Patel NH,Sandler RH

    更新日期:2005-01-01 00:00:00

  • Personal computer system for ECG ST-segment recognition based on neural networks.

    abstract::A personal computer system for electrocardiogram (ECG) ST-segment recognition is developed based on neural networks. The system consists of a preprocessor, neural networks and a recogniser. The adaptive resonance theory (ART) is employed to implement the neural networks in the system, which self-organise in response t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446186

    authors: Suzuki Y,Ono K

    更新日期:1992-01-01 00:00:00

  • Methods of dynamic spectral analysis by self-exciting autoregressive moving average models and their application to analysing biosignals.

    abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510536

    authors: Schack B,Bareshova E,Grieszbach G,Witte H

    更新日期:1995-05-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • Recording of physiological signals with domestic videotape storage.

    abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02447101

    authors: Salvador CH,Rosende P,González MA

    更新日期:1991-03-01 00:00:00

  • Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results.

    abstract::To evaluate the possibility of respiratory-volume measurement using photoplethysmography (PPG), PPG signals from 16 normal volunteers are collected, and the respiratory-induced intensity variations (RIIV) are digitally extracted. The RIIV signals are studied while respiratory volume is varied. Furthermore, respiratory...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513264

    authors: Johansson A,Oberg PA

    更新日期:1999-01-01 00:00:00

  • MicroPACS: a PC-based small PACS implementation.

    abstract::To make picture archiving and communication systems (PACS) a practical reality for small-scale structures, it appears necessary to build a network that integrates and optimises production management, analysis and storage of images, and to include the ability to communicate with other similar remote structures. To solv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02458046

    authors: Duchêne J,Lerallut JF,Gong N,Kanz R

    更新日期:1993-05-01 00:00:00

  • Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect.

    abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345312

    authors: Han BH,Lee SY,Kim JH,Yi JH

    更新日期:2003-09-01 00:00:00

  • Influence of synchronous and sequential stimulation on muscle fatigue.

    abstract::In acute experiments the sciatic nerve of the rat is electrically stimulated to induce fatigue in the medial Gastrocnemius muscle. Fatigue tests are carried out using intermittent stimulation of different compartments (sequential) or a single compartment (synchronous) of the sciatic nerve. The activation of different ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530036

    authors: Thomsen M,Veltink PH

    更新日期:1997-05-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00

  • Biomechanical analysis of structural deformation in living cells.

    abstract::Most tissues are subject to some form of physiological mechanical loading which results in deformation of the cells triggering intracellular mechanotransduction pathways. This response to loading is generally essential for the health of the tissue, although more pronounced deformation may result in cell and tissue dam...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-008-0381-4

    authors: Bader DL,Knight MM

    更新日期:2008-10-01 00:00:00

  • Modelling the dynamics of expiratory airflow to describe chronic obstructive pulmonary disease.

    abstract::Chronic obstructive pulmonary disease (COPD) is characterized by expiratory airflow limitation, but current diagnostic criteria only consider flow till the first second and are therefore strongly debated. We aimed to develop a data-based individualized model for flow decline and to explore the relationship between mod...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1202-6

    authors: Topalovic M,Exadaktylos V,Decramer M,Troosters T,Berckmans D,Janssens W

    更新日期:2014-12-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

    abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0741-3

    authors: Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau A

    更新日期:2011-04-01 00:00:00

  • Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

    abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520078

    authors: Bray R,Forrester K,McDougall JJ,Damji A,Ferrell WR

    更新日期:1996-05-01 00:00:00

  • Dynamic simulation of the natural and replaced human ankle joint.

    abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348124

    authors: Leardini A,Moschella D

    更新日期:2002-03-01 00:00:00

  • Computer simulation of electronic interactions during excitation and repolarisation of myocardial tissue.

    abstract::A three-dimensional model of myocardial tissue has been developed which incorporates electrotonic interactions between neighbouring myocytes. The algorithms of the model are based on asynchronous planning of discrete events. Each cellular element is described in a logical way and traces a predefined action potential w...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441665

    authors: Malik M,Camm AJ

    更新日期:1991-07-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00