Varying ultrasound power level to distinguish surgical instruments and tissue.

Abstract:

:We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

journal_name

Med Biol Eng Comput

authors

Ren H,Anuraj B,Dupont PE

doi

10.1007/s11517-017-1695-x

subject

Has Abstract

pub_date

2018-03-01 00:00:00

pages

453-467

issue

3

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-017-1695-x

journal_volume

56

pub_type

杂志文章
  • Mechanical and electromotile characteristics of auditory outer hair cells.

    abstract::The passive and active properties of the cochlear outer hair cell are studied. The outer hair cell is currently considered the major candidate for the active component of mammalian hearing. Understanding of its properties may explain the amplification and sharp frequency selectivity of the ear. To analyse the cell beh...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513294

    authors: Spector AA,Brownell WE,Popel AS

    更新日期:1999-03-01 00:00:00

  • Performance analysis of melanoma classifier using electrical modeling technique.

    abstract::An efficient and novel modeling approach is proposed in this paper for identifying proteins or genes involved in melanoma skin cancer. Two types of classifiers are modeled, based on the chemical structure and hydropathy property of amino acids. These classifiers are further implemented using NI LabVIEW-based hardware ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02241-6

    authors: Roy T,Bhattacharjee P

    更新日期:2020-10-01 00:00:00

  • Prognostic factors in the prediction of chronic wound healing by electrical stimulation.

    abstract::The aim of the study is to determine the effects of wound, patient and treatment attributes on the wound healing rate and to propose a system for wound healing rate prediction. Predicting the wound healing rate from the initial wound, patient and treatment data collected in a database of 300 chronic wounds is not poss...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345144

    authors: Cukjati D,Robnik-Sikonja M,Rebersek S,Kononenko I,Miklavcic D

    更新日期:2001-09-01 00:00:00

  • Improved photomultiplier tube for positron emission tomography.

    abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441486

    authors: Woldeselassie T

    更新日期:1989-05-01 00:00:00

  • Assessment of heart rate variability by application of central tendency measure.

    abstract::The heart rate variability (HRV) is an indicator of the subject homeostasis alterations. For a healthy individual, the HRV shows a nonlinear behavior, thus requiring a nonlinear approach to provide additional information about HRV dynamics. In this work, the nonlinear techniques, central tendency measure (CTM) and sec...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1390-8

    authors: dos Santos L,Barroso JJ,Macau EE,de Godoy MF

    更新日期:2015-11-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

    abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1458-0

    authors: Halevi R,Hamdan A,Marom G,Lavon K,Ben-Zekry S,Raanani E,Bluestein D,Haj-Ali R

    更新日期:2016-11-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique.

    abstract::Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351031

    authors: Karlsson MG,Fors C,Wårdell K,Casimir-Ahn H

    更新日期:2005-09-01 00:00:00

  • A new combination: scale-space filtering of projected brain activities.

    abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0450-3

    authors: Aydin S

    更新日期:2009-04-01 00:00:00

  • A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

    abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02101-y

    authors: Ilhan HO,Sigirci IO,Serbes G,Aydin N

    更新日期:2020-05-01 00:00:00

  • Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

    abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1752-5

    authors: Naidu SMM,Pandey PC,Bagal UR,Hardas SP

    更新日期:2018-06-01 00:00:00

  • Quantitative measurement of Parkinsonian gait from walking in monocular image sequences using a centroid tracking algorithm.

    abstract::Parkinson's disease (PD) is a neurodegenerative disease of the central nervous system that results from the degeneration of dopaminergic neurons in the substantia nigra. Abnormal gait begins in the early stage and becomes severe as the disease progresses; therefore, the assessment of gait becomes an important issue in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1335-2

    authors: Lin SH,Chen SW,Lo YC,Lai HY,Yang CH,Chen SY,Chang YJ,Chen CH,Huang WT,Jaw FS,Chen YY,Tsang S,Liao LD

    更新日期:2016-03-01 00:00:00

  • Wireless and inductively powered implant for measuring electrocardiogram.

    abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-007-0264-0

    authors: Riistama J,Väisänen J,Heinisuo S,Harjunpää H,Arra S,Kokko K,Mäntylä M,Kaihilahti J,Heino P,Kellomäki M,Vainio O,Vanhala J,Lekkala J,Hyttinen J

    更新日期:2007-12-01 00:00:00

  • "Hippocrates-mst": a prototype for computer-aided microcalcification analysis and risk assessment for breast cancer.

    abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0117-2

    authors: Spyrou G,Kapsimalakou S,Frigas A,Koufopoulos K,Vassilaros S,Ligomenides P

    更新日期:2006-11-01 00:00:00

  • Evaluation of high resolution thermal imaging to determine the effect of vertebral fractures on associated skin surface temperature in children with osteogenesis imperfecta.

    abstract::Vertebral fractures are common in children with osteogenesis imperfecta (OI). Current imaging methods for fracture detection (X-ray and DXA) use ionising radiation. This pilot study explored whether the alteration in blood flow in vertebral fractures results in skin temperature changes that may be detected using high ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1806-3

    authors: Fane De Salis A,Saatchi R,Dimitri P

    更新日期:2018-09-01 00:00:00

  • Delineation of the ischemic stroke lesion based on watershed and relative fuzzy connectedness in brain MRI.

    abstract::Precise segmentation of stroke lesions from brain magnetic resonance (MR) images poses a challenging task in automated diagnosis. In this paper, we proposed a new method called watershed-based lesion segmentation algorithm (WLSA), which is a novel intensity-based segmentation technique used to delineate infarct lesion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1726-7

    authors: Subudhi A,Jena S,Sabut S

    更新日期:2018-05-01 00:00:00

  • CT analysis of the use of the electrical impedance technique to estimate local oedema in the extremities in patients with lymphatic obstruction.

    abstract::The aim of the study is to establish the validity of the use of the electrical impedance technique for estimating local oedema in extremities through comparison with computed-tomography (CT) analysis. Eight healthy women (group 1) and nine women with unilateral leg oedema following chronic lymphatic obstruction (group...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522859

    authors: Watanabe R,Kotoura H,Morishita Y

    更新日期:1998-01-01 00:00:00

  • Biphasic model of the trabecular meshwork in the eye.

    abstract::A biphasic continuum model for the flow of intraocular fluid, the aqueous humour, in the trabecular meshwork is proposed in the paper. The model considers the meshwork as a circular ring with uniform thickness of homogeneous, isotropic, viscoelastic material swollen with continuously percolating aqueous humour. The mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446710

    authors: Tandon PN,Autar R

    更新日期:1991-05-01 00:00:00

  • Estimating germinability of Plasmopara viticola oospores by means of neural networks.

    abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344698

    authors: Vercesi A,Sirtori C,Vavassori A,Setti E,Liberati D

    更新日期:2000-01-01 00:00:00

  • Analysis of amplitude and frequency variations of essential and Parkinsonian tremors.

    abstract::Variations in the amplitude and period of essential and Parkinsonian tremors were studied. It was found that the variations in frequency (or period) were mostly similar to the white noise, with the standard deviation typically less than 10% of the mean, whereas the variations in amplitude were much larger, with standa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344710

    authors: Gao JB

    更新日期:2004-05-01 00:00:00

  • Multi-parametric cardiorespiratory analysis in late-preterm, early-term, and full-term infants at birth.

    abstract::Infants born at 35-37 weeks' gestational age (GA) are at higher risk for a range of pathological conditions and poorer neurodevelopmental outcomes. However, mechanisms responsible are not fully understood. The purpose of this paper is to use traditional and novel techniques to assess newborn autonomic development as a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1866-4

    authors: Lucchini M,Burtchen N,Fifer WP,Signorini MG

    更新日期:2019-01-01 00:00:00

  • Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.

    abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0741-3

    authors: Collette M,Lalande A,Willoteaux S,Leftheriotis G,Humeau A

    更新日期:2011-04-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Spatio-spectral filters for low-density surface electromyographic signal classification.

    abstract::In this paper, we proposed to utilize a novel spatio-spectral filter, common spatio-spectral pattern (CSSP), to improve the classification accuracy in identifying intended motions based on low-density surface electromyography (EMG). Five able-bodied subjects and a transradial amputee participated in an experiment of e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1024-3

    authors: Huang G,Zhang Z,Zhang D,Zhu X

    更新日期:2013-05-01 00:00:00

  • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

    abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344773

    authors: Ensell G,Banks DJ,Richards PR,Balachandran W,Ewins DJ

    更新日期:2000-03-01 00:00:00

  • Robust segmentation and intelligent decision system for cerebrovascular disease.

    abstract::Segmentation and classification of low-quality and noisy ultrasound images is challenging task. In this paper, a new approach is proposed for robust segmentation and classification of carotid artery ultrasound images and consequently, detecting cerebrovascular disease. The proposed technique consists of two phases, in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1481-1

    authors: Chaudhry A,Hassan M,Khan A

    更新日期:2016-12-01 00:00:00

  • Detection of compressed tracheal sound patterns with large amplitude variation during sleep.

    abstract::The objective of the present work was to develop automated methods for the compressed tracheal breathing sound analysis. Overnight tracheal breathing sound was recorded from ten apnoea patients. From each patient, three different types of tracheal sound deflection pattern, each of 10 min duration, were visually scored...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0317-z

    authors: Kulkas A,Rauhala E,Huupponen E,Virkkala J,Tenhunen M,Saastamoinen A,Himanen SL

    更新日期:2008-04-01 00:00:00

  • Continuous flow left ventricular pump support and its effect on regional left ventricular wall stress: finite element analysis study.

    abstract::Left ventricular assist device (LVAD) support unloads left ventricular (LV) pressure and volume and decreases wall stress. This study investigated the effect of systematic LVAD unloading on the 3-dimensional myocardial wall stress by employing finite element models containing layered fiber structure, active contractil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1205-3

    authors: Jhun CS,Sun K,Cysyk JP

    更新日期:2014-12-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00