Abstract:
:Segmentation and classification of low-quality and noisy ultrasound images is challenging task. In this paper, a new approach is proposed for robust segmentation and classification of carotid artery ultrasound images and consequently, detecting cerebrovascular disease. The proposed technique consists of two phases, in first phase; it refines the class labels selected by user using expectation maximization algorithm. Genetic algorithm is then employed to select discriminative features based on moments of gray-level histogram. The selected features and refined targets are fed as input to neuro-fuzzy classifier for performing segmentation. Finally, intima-media thickness values are measured from segmented images to segregate the normal and abnormal subjects. In second phase, an intelligent decision-making system based on support vector machine is developed to utilize the intima-media thickness values for detecting cerebrovascular disease. The proposed robust segmentation and classification technique for ultrasound images (RSC-US) has been tested on a dataset of 300 real carotid artery ultrasound images and yields accuracy, F-measure, and MCC scores of 98.84, 0.988, 0.9767 %, respectively, using jackknife test. The segmentation and classification performance of the proposed (RSC-US) has been also tested at several noise levels and may be used as secondary observation.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Chaudhry A,Hassan M,Khan Adoi
10.1007/s11517-016-1481-1subject
Has Abstractpub_date
2016-12-01 00:00:00pages
1903-1920issue
12eissn
0140-0118issn
1741-0444pii
10.1007/s11517-016-1481-1journal_volume
54pub_type
杂志文章abstract::Sino-aortic denervation (SAD) is employed in cats to evaluate the baroreflex influence on blood pressure (BP) and pulse interval (PI) spectral components from 0.00008 to 0.9 Hz as assessed by FFT wide-band spectra and their 1/f modelling; and the linear coupling between BP and PI and between systolic and diastolic BP ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02520018
更新日期:1996-03-01 00:00:00
abstract::Stiffness of the arterial wall and atherosclerotic plaque components is a determinant of the stress field within plaques, which has been suggested to be an indicator of plaque vulnerability. The diversity and inhomogeneous structure of atherosclerotic lesions complicate the characterization of plaque components. In th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1910-4
更新日期:2019-03-01 00:00:00
abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0224-8
更新日期:2007-10-01 00:00:00
abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344215
更新日期:2002-05-01 00:00:00
abstract::Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the inte...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02524426
更新日期:1998-09-01 00:00:00
abstract::The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a cl...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-019-02077-9
更新日期:2020-06-01 00:00:00
abstract::Significant efforts were invested during the last decade to accelerate PET list-mode reconstructions, notably with GPU devices. However, the computation time per event is still relatively long, and the list-mode efficiency on the GPU is well below the histogram-mode efficiency. Since list-mode data are not arranged in...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1284-9
更新日期:2015-09-01 00:00:00
abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1110-1
更新日期:2014-01-01 00:00:00
abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1403-7
更新日期:2016-09-01 00:00:00
abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345011
更新日期:2000-07-01 00:00:00
abstract::Many studies concerning the internal work of human motion have used two-dimensional kinematic models to estimate kinetic energy of the segments. The generalised co-ordinate concept has been applied here to a simultaneous and bilateral gait analysis. A three-dimensional kinematic model based on quaternions has been dev...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523852
更新日期:1996-11-01 00:00:00
abstract::The purpose of the study was to explore the application of artificial neural network model in the auxiliary diagnosis of lung cancer and compare the effects of back-propagation (BP) neural network with Fisher discrimination model for lung cancer screening by the combined detections of four biomarkers of p16, RASSF1A a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1585-7
更新日期:2017-08-01 00:00:00
abstract::Reactive hyperaemia is the term given to the temporary increase in blood flow that follows release of an occlusion of the arterial supply. Measurement of reactive hyperaemia in the leg below the knee is useful in assessment of the vascular system, as resting flows remain unaffected even in the presence of quite severe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02515312
更新日期:1994-09-01 00:00:00
abstract::The aim of this study was the analysis of the mechanical behaviour of a partially porous lumbar custom-made cage by means of a subject-specific finite element analysis (FEA). The cage, made of Ti6Al4V ELI alloy, was produced via electron beam melting (EBM) process and surgically implanted in a female subject, 50 years...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02078-8
更新日期:2019-12-01 00:00:00
abstract::Vertebral fractures are common in children with osteogenesis imperfecta (OI). Current imaging methods for fracture detection (X-ray and DXA) use ionising radiation. This pilot study explored whether the alteration in blood flow in vertebral fractures results in skin temperature changes that may be detected using high ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1806-3
更新日期:2018-09-01 00:00:00
abstract::The clinical efficacy of a microwave (MW) hyperthermia system using an electric-field converging (lens) applicator is evaluated for 42 malignant tumours with a maximum tumour depth of less than 7 cm. The mean of the maximum, average and minimum tumour temperature of the 42 tumours are 44.5, 42.5 and 40.7 C, respective...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02522944
更新日期:1995-01-01 00:00:00
abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1628-8
更新日期:2017-09-01 00:00:00
abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02512522
更新日期:1994-05-01 00:00:00
abstract::The regulation of the coronary circulation is a complex paradigm in which many inputs that influence vasomotor tone have to be integrated to provide the coronary vasomotor adjustments to cardiac metabolism and to perfusion pressure. We hypothesized that the integration of many disparate signals that influence membrane...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0329-8
更新日期:2008-05-01 00:00:00
abstract::Widespread misconceptions still exist regarding the formation of extracellular potentials over the innervation zone: the assumption (1) that the first phase of these potentials mainly reflects the process of initiation of the intracellular action potential (IAP) at the neuromuscular junction and that (2) these potenti...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1487-8
更新日期:2016-12-01 00:00:00
abstract::In this study, we propose an integrated tooth segmentation and gingival tissue deformation simulation framework used to design and evaluate the orthodontic treatment plan especially with invisible aligners. Firstly, the bio-characteristics information of the digital impression is analyzed quantitatively and demonstrat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02230-9
更新日期:2020-10-01 00:00:00
abstract::To describe the spatial and temporal profiles of connectivity networks and sources preceding generalized spike-and-wave discharges (SWDs) in human absence epilepsy. Nonlinear associations of MEG signals and cluster indices obtained within the framework of graph theory were determined, while source localization in the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0778-3
更新日期:2011-05-01 00:00:00
abstract::Gastrointestinal stimulator implants have recently shown positive results in treating obesity. However, the implantation currently requires an invasive surgical procedure. Endoscopy could be used to place the gastric stimulator in the stomach, hence avoiding the riskier surgery. The implant then needs to go through th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1236-9
更新日期:2015-04-01 00:00:00
abstract::Apoptosis proteins are related to many diseases. Obtaining the subcellular localization information of apoptosis proteins is helpful to understand the mechanism of diseases and to develop new drugs. At present, the researchers mainly focus on the primary protein sequences, so there is still room for improvement in the...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02045-3
更新日期:2019-12-01 00:00:00
abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1818-z
更新日期:2018-11-01 00:00:00
abstract::Divided attention is defined as focusing on different tasks at once, and this is described as one of the biggest problems of today's society. Default examinations for understanding attention are questionnaires or physiological signals, like evoked potentials and electroencephalography. Physiological records were obtai...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02013-x
更新日期:2019-09-01 00:00:00
abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01995-y
更新日期:2019-08-01 00:00:00
abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02082-y
更新日期:2020-02-01 00:00:00
abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-007-0264-0
更新日期:2007-12-01 00:00:00
abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0972-y
更新日期:2013-02-01 00:00:00