Abstract:
:The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenomena between respiration, HRV and BPV during cardiorespiratory synchronisation experiments, by using the following time-domain techniques: Poincaré maps, recurrence plots, time-space separation plots and frequency tracking locus. The experimental protocol consists of three stages, with normal subjects in paced breathing at 15, 12 and 8 breaths min-1. Transient phenomena of coordination between respiration and the major rhythms of HRV and BPV (low and high frequency, LF and HF) have been detected and classified: no interaction between LF and HF rhythms at 15 breaths min-1; short time intervals of stable 1:2 frequency and phase synchronisation during the 12 breaths min-1 stage; 1:1 PL during the 8 breaths min-1 stage. 1:1 and 1:2 PL phenomena occurred when the respiration frequency was quite close to the LF frequency or when it was about twice the LF frequency, respectively. The complex organisation of the ANS seems to provoke transient rather than permanent PL phenomena between the co-ordinating components of respiration and cardiovascular variability series.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti Sdoi
10.1007/BF02345011keywords:
subject
Has Abstractpub_date
2000-07-01 00:00:00pages
416-26issue
4eissn
0140-0118issn
1741-0444journal_volume
38pub_type
杂志文章abstract::Obstructive sleep apnea syndrome (OSAS) is a major public health problem. The golden reference for diagnosing OSAS is the sleep-laboratory based polysomnography (PSG). However, screening of population for OSAS may be practical and cost efficient only through ambulatory home recordings. In this work we aimed to design,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0418-8
更新日期:2009-01-01 00:00:00
abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02088-6
更新日期:2020-02-01 00:00:00
abstract::In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different seque...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1302-y
更新日期:2015-10-01 00:00:00
abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-016-1572-z
更新日期:2017-06-01 00:00:00
abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-007-0264-0
更新日期:2007-12-01 00:00:00
abstract::In this study, we present finite element analysis models to calculate the increase in intrathoracic volume of pectus excavatum patients after the Nuss procedure. One virtue of our approach is that the measurement of the intrathoracic volume has no time difference and is not affected by postoperative pain, which cannot...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0570-9
更新日期:2010-02-01 00:00:00
abstract::A hypothetical neuromusculoskeletal model is developed to simulate human normal walking and its modulated behaviors. A small set of neural periodic patterns drive spinal muscle synergies which in turn lead to specific pattern of muscle activation and supraspinal feedback systems maintain postural balance during walkin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0277-8
更新日期:2008-02-01 00:00:00
abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345957
更新日期:2005-03-01 00:00:00
abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441487
更新日期:1989-05-01 00:00:00
abstract::A computer-assisted human peripheral blood leukocyte image classification method based on Siamese network is proposed. Firstly, a Siamese network with two identical convolutional neural network (CNN) sub-networks and a logistic regression for leukocyte five classification is designed, which can learn not only distingu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02180-2
更新日期:2020-07-01 00:00:00
abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523031
更新日期:1995-03-01 00:00:00
abstract::The paper describes the application of new semi-automatic segmentation software to the task of detection of anatomical structures and lesion and their three-dimensional (3D) visualisation in 23 patients with secondary progressive multiple sclerosis (MS). The purpose is to study the correlation between magnetic resonan...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513274
更新日期:1999-01-01 00:00:00
abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345809
更新日期:2005-05-01 00:00:00
abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1887-z
更新日期:2019-01-01 00:00:00
abstract::Pre-operative diagnosis of chest-wall deformity is important for successful surgical correction and post-operative evaluation of funnel chest patients. However, conventional indices that define the severity of deformity have several limitations; manually calculated and cannot supply information about asymmetry. We dev...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0367-2
更新日期:2008-08-01 00:00:00
abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02277-8
更新日期:2021-01-01 00:00:00
abstract::A new transducer has been developed, based on an inductive principle, for recording fetal movements and sounds. The compliance of this transducer, the INductive PHOno-sensor (INPHO), can be matched to that of the maternal abdomen to provide an optimal transfer of displacement between maternal abdomen and transducer. I...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441655
更新日期:1991-07-01 00:00:00
abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02534088
更新日期:1997-07-01 00:00:00
abstract::The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344888
更新日期:2003-03-01 00:00:00
abstract::The effectiveness of electrochemotherapy, a local treatment using electric pulses to increase the uptake of chemotherapeutic drug, includes several antitumor mechanisms. In addition to the cytotoxic action of chemotherapeutic drug, treatment outcome also depends on antitumor immune response. In order to assess the con...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1562-1
更新日期:2017-07-01 00:00:00
abstract::This review is a commentary on recent, altered perspectives about biomedical engineering and its role in medicine. It is argued that, rather than being a peripheral specialty, medical engineering and engineering principles in general have a direct application to biochemical medicine and cell biology. A brief descripti...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02446170
更新日期:1992-07-01 00:00:00
abstract::Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-016-1524-7
更新日期:2017-03-01 00:00:00
abstract::The aim of this study was to design a new approach for the acquisition of regional radial strain from the middle portion of the interventricular septum. We designed and wrote a program in Matlab (computer-assisted method) for use on a personal computer so that the septum thickness throughout the cardiac cycle could be...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0222-x
更新日期:2007-09-01 00:00:00
abstract::Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation, including telemedicine applications. Low-voltage and low-power design tendencies prevail. Modern battery cell voltages in the range of 3-3.6 V require appropriate circuit solutions. A two-electrode biopotentia...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344642
更新日期:2004-03-01 00:00:00
abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446086
更新日期:1991-11-01 00:00:00
abstract::We estimated the dynamic cell metabolic activity and the distribution of the pH value and oxygen concentration in tissue samples cultured in vitro by using real-time sensor records and a numerical simulation of the underlying reaction-diffusion processes. As an experimental tissue model, we used chicken spleen slices....
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1367-7
更新日期:2016-05-01 00:00:00
abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02101-y
更新日期:2020-05-01 00:00:00
abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0497-1
更新日期:2009-08-01 00:00:00
abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1799-y
更新日期:2018-09-01 00:00:00
abstract::The aim of this study was to develop a radiation-free method to measure gastric emptying. Such a method would be useful e.g. for patients who need repeated measurements and in pregnancy. Ferrimagnetic particles (gamma-Fe2O3), ingested within a solid test meal (pancakes), were magnetised by an applied magnetic field. A...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/BF02522849
更新日期:1998-01-01 00:00:00