Two-electrode low supply voltage electrocardiogram signal amplifier.

Abstract:

:Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation, including telemedicine applications. Low-voltage and low-power design tendencies prevail. Modern battery cell voltages in the range of 3-3.6 V require appropriate circuit solutions. A two-electrode biopotential amplifier design is presented, with a high common-mode rejection ratio (CMRR), high input voltage tolerance and standard first-order high-pass characteristic. Most of these features are due to a high-gain first stage design. The circuit makes use of passive components of popular values and tolerances. Powered by a single 3 V source, the amplifier tolerates +/- 1 V common mode voltage, +/- 50 microA common mode current and 2 V input DC voltage, and its worst-case CMRR is 60 dB. The amplifier is intended for use in various applications, such as Holter-type monitors, defibrillators, ECG monitors, biotelemetry devices etc.

journal_name

Med Biol Eng Comput

authors

Dobrev D

doi

10.1007/BF02344642

keywords:

subject

Has Abstract

pub_date

2004-03-01 00:00:00

pages

272-6

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

42

pub_type

杂志文章
  • Interpreting magnetic fields of the brain: minimum norm estimates.

    abstract::The authors have applied estimation theory to the problem of determining primary current distributions from measured neuromagnetic fields. In this procedure, essentially nothing is assumed about the source currents, except that they are spatially restricted to a certain region. Simulation experiments show that the res...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512476

    authors: Hämäläinen MS,Ilmoniemi RJ

    更新日期:1994-01-01 00:00:00

  • Dielectric relaxation of a protein-water system in atherosclerotic artery wall.

    abstract::Measurements of the dielectric properties of healthy and atherosclerotic human artery tissues were made in the frequency range of 100 Hz-100 kHz and temperatures from 22 to 260 degrees C. The temperature dependencies of the dielectric parameters for healthy tissues reveal distinctively the temperature ranges correspon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0181-2

    authors: Brzeziński J,Oszkinis G,Marzec E

    更新日期:2007-06-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

    abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522869

    authors: Kataoka N,Ujita S,Sato M

    更新日期:1998-01-01 00:00:00

  • Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

    abstract::A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518911

    authors: Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

    更新日期:1994-03-01 00:00:00

  • Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

    abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520078

    authors: Bray R,Forrester K,McDougall JJ,Damji A,Ferrell WR

    更新日期:1996-05-01 00:00:00

  • Personal computer system for ECG ST-segment recognition based on neural networks.

    abstract::A personal computer system for electrocardiogram (ECG) ST-segment recognition is developed based on neural networks. The system consists of a preprocessor, neural networks and a recogniser. The adaptive resonance theory (ART) is employed to implement the neural networks in the system, which self-organise in response t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446186

    authors: Suzuki Y,Ono K

    更新日期:1992-01-01 00:00:00

  • Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.

    abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1589-3

    authors: Mi Y,Rui S,Li C,Yao C,Xu J,Bian C,Tang X

    更新日期:2017-07-01 00:00:00

  • Determining appropriate models for joint control using surface electrical stimulation of soleus in spinal cord injury.

    abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512522

    authors: Flaherty B,Robinson C,Agarwal G

    更新日期:1994-05-01 00:00:00

  • Contact mechanics of a thin-walled capsule adhered onto a rigid planar substrate.

    abstract::A thin-walled capsule, modelled as an incompressible liquid droplet contained in a thin flexible membrane, was allowed to adhere onto a rigid substrate. The contact mechanics were formulated, based on linear elasticity, to portray quantitatively the relationships between osmotic inflation, contact area and angle, memb...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345154

    authors: Wan KT,Liu KK

    更新日期:2001-09-01 00:00:00

  • Corrected formula for estimating peripheral blood flow by impedance plethysmography.

    abstract::In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524237

    authors: Jindal GD,Nerurkar SN,Pednekar SA,Babu JP,Bhuta AC,Deshpande AK

    更新日期:1994-11-01 00:00:00

  • Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure.

    abstract::Smoothing and differentiation of noisy signals are common problems whenever it is difficult or impossible to obtain derivatives by direct measurement. In biomechanics body displacements are frequently assessed and these measurements are affected by noise. To avoid high-frequency noise magnification, data filtering bef...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441963

    authors: D'Amico M,Ferrigno G

    更新日期:1990-09-01 00:00:00

  • Computational wrist analysis of functional restoration after scapholunate dissociation repair.

    abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01971-6

    authors: Wayne JS,Tremols EJ

    更新日期:2019-07-01 00:00:00

  • Dual-sectored transurethral ultrasound for thermal treatment of stress urinary incontinence: in silico studies in 3D anatomical models.

    abstract::The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulation...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02152-6

    authors: Liu D,Adams M,Burdette EC,Diederich CJ

    更新日期:2020-06-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • Effect of the shape and configuration of smooth muscle cells on the diffusion of ATP through the arterial wall.

    abstract::In this study, the shape and the configuration of smooth muscle cells (SMCs) within the arterial wall are altered to investigate their influence on molecular transport across the media layer of the thoracic aorta wall. In a 2D geometry of the media layer containing SMCs, the finite-element method has been employed to ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0219-5

    authors: Dabagh M,Jalali P,Sarkomaa P

    更新日期:2007-11-01 00:00:00

  • Repolarization variability independent of heart rate during sympathetic activation elicited by head-up tilt.

    abstract::The fraction of repolarization variability independent of RR interval variability is of clinical interest. It has been linked to direct autonomic nervous system (ANS) regulation of the ventricles in healthy subjects and seems to reflect the instability of the ventricular repolarization process in heart disease. In thi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01998-9

    authors: El-Hamad F,Javorka M,Czippelova B,Krohova J,Turianikova Z,Porta A,Baumert M

    更新日期:2019-08-01 00:00:00

  • Theoretical evaluation of a simple cooling pad for inducing hypothermia in the spinal cord following traumatic injury.

    abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0543-z

    authors: Smith KD,Zhu L

    更新日期:2010-02-01 00:00:00

  • Comparison between human awake, meditation and drowsiness EEG activities based on directed transfer function and MVDR coherence methods.

    abstract::This study examined the electroencephalogram functional connectivity (coherence) and effective connectivity (flow of information) of selected brain regions during three different attentive states: awake, meditation and drowsiness. For the estimation of functional connectivity (coherence), Welch and minimum variance di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1272-0

    authors: Dissanayaka C,Ben-Simon E,Gruberger M,Maron-Katz A,Sharon H,Hendler T,Cvetkovic D

    更新日期:2015-07-01 00:00:00

  • Apnea bradycardia detection based on new coupled hidden semi Markov model.

    abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02277-8

    authors: Montazeri Ghahjaverestan N,Shamsollahi MB,Ge D,Beuchée A,Hernández AI

    更新日期:2021-01-01 00:00:00

  • Photoplethysmography. Part 2. Influence of light source wavelength.

    abstract::When the microvascular blood perfusion in human skin is measured by photoplethysmography (PPG), infra-red light (800-960 nm) is normally used as the light source. The PPG signal, which consists of a pulsatile (AC) and a slowly fluctuating (DC) component, was studied at different optical wavelengths utilising optical f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446295

    authors: Lindberg LG,Oberg PA

    更新日期:1991-01-01 00:00:00

  • Development of an eye-movement analyser possessing functions for wireless transmission and autocalibration.

    abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446149

    authors: Yamada M,Fukuda T,Hirota M

    更新日期:1990-07-01 00:00:00

  • Estimation of the lactate threshold using an electro acoustic sensor system analysing the respiratory air.

    abstract::The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0373-4

    authors: Folke M

    更新日期:2008-09-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Towards a patient-specific hepatic arterial modeling for microspheres distribution optimization in SIRT protocol.

    abstract::Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1703-1

    authors: Simoncini C,Jurczuk K,Reska D,Esneault S,Nunes JC,Bellanger JJ,Saint-Jalmes H,Rolland Y,Eliat PA,Bézy-Wendling J,Kretowski M

    更新日期:2018-03-01 00:00:00

  • Classification of the long-QT syndrome based on discriminant analysis of T-wave morphology.

    abstract::The long QT syndrome (LQTS) is a genetic disorder, typically characterized by a prolonged QT interval in the ECG due to abnormal cardiac repolarization. LQTS may lead to syncopal episodes and sudden cardiac death. Various parameters based on T-wave morphology, as well as the QT interval itself have been shown to be us...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0061-1

    authors: Struijk JJ,Kanters JK,Andersen MP,Hardahl T,Graff C,Christiansen M,Toft E

    更新日期:2006-07-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Spectral analysis of heart rate variability using the integral pulse frequency modulation model.

    abstract::Spectral analysis of heart rate variability (HRV) is a widely accepted approach for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. As a rule, the non-parametric methods for HRV spectral analysis are tested using the integral pulse frequency modulation (IPFM) model. Ho...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345290

    authors: Mitov IP

    更新日期:2001-05-01 00:00:00

  • Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

    abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0827-y

    authors: Bousbiat S,Jaffrin MY,Dongmo E

    更新日期:2011-11-01 00:00:00

  • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

    abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534137

    authors: Scharfetter H,Wirnsberger GH,Holzer H,Hutten H

    更新日期:1997-03-01 00:00:00