Interpreting magnetic fields of the brain: minimum norm estimates.

Abstract:

:The authors have applied estimation theory to the problem of determining primary current distributions from measured neuromagnetic fields. In this procedure, essentially nothing is assumed about the source currents, except that they are spatially restricted to a certain region. Simulation experiments show that the results can describe the structure of the current flow fairly well. By increasing the number of measurements, the estimate can be made more localised. The current distributions may be also used as an interpolation and an extrapolation for the measured field patterns.

journal_name

Med Biol Eng Comput

authors

Hämäläinen MS,Ilmoniemi RJ

doi

10.1007/BF02512476

subject

Has Abstract

pub_date

1994-01-01 00:00:00

pages

35-42

issue

1

eissn

0140-0118

issn

1741-0444

journal_volume

32

pub_type

杂志文章
  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00

  • Dielectric properties of bones for the monitoring of osteoporosis.

    abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-018-1887-z

    authors: Amin B,Elahi MA,Shahzad A,Porter E,McDermott B,O'Halloran M

    更新日期:2019-01-01 00:00:00

  • Pulsatile blood flow in total cavopulmonary connection: a comparison between Y-shaped and T-shaped geometry.

    abstract::Single-ventricle anomaly is a hereditary heart disease that is characterized by anatomical malformations. The main consequence of this malformation is desaturated blood flow, which without proper treatment increases the risk of death. The classical treatment is based on a three-stage palliative procedure which should ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1499-4

    authors: Rajabzadeh-Oghaz H,Firoozabadi B,Saidi MS,Monjezi M,Navabi Shirazi MA,Malakan Rad E

    更新日期:2017-02-01 00:00:00

  • Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

    abstract::Monitoring upper-limb activity in a free-living environment is important for the evaluation of rehabilitation. This study is a validation of the Strathclyde Upper-Limb Activity Monitor (SULAM) which records the vertical movement and position of each wrist, and assesses bimanual movement. Agreement between the SULAM an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0233-7

    authors: Vega-Gonzalez A,Bain BJ,Dall PM,Granat MH

    更新日期:2007-10-01 00:00:00

  • Dual-sectored transurethral ultrasound for thermal treatment of stress urinary incontinence: in silico studies in 3D anatomical models.

    abstract::The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulation...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02152-6

    authors: Liu D,Adams M,Burdette EC,Diederich CJ

    更新日期:2020-06-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • ML and MAP estimation of parameters for the Kalman filter and smoother applied to electrocardiographic imaging.

    abstract::In electrocardiographic imaging (ECGI), one solves the inverse problem of electrocardiography (ECG) to reconstruct equivalent cardiac sources based on the body surface potential measurements and a mathematical model of the torso. Due to attenuation and spatial smoothing within the torso, this inverse problem is ill-po...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02018-6

    authors: Erenler T,Serinagaoglu Dogrusoz Y

    更新日期:2019-10-01 00:00:00

  • Design of a novel mobility device controlled by the feet motion of a standing child: a feasibility study.

    abstract::Self-generated mobility is a major contributor to the physical, emotional, cognitive, and social development of infants and toddlers. When young children have disorders that hinder self locomotion, their development is at risk for delay. Independent mobility via traditional power mobility devices may prevent this dela...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0820-5

    authors: Schoepflin ZR,Chen X,Ragonesi CB,Galloway JC,Agrawal SK

    更新日期:2011-10-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • Filtered maximum likelihood expectation maximization based global reconstruction for bioluminescence tomography.

    abstract::The reconstruction of bioluminescence tomography (BLT) is severely ill-posed due to the insufficient measurements and diffuses nature of the light propagation. Predefined permissible source region (PSR) combined with regularization terms is one common strategy to reduce such ill-posedness. However, the region of PSR i...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1842-z

    authors: Yang D,Wang L,Chen D,Yan C,He X,Liang J,Chen X

    更新日期:2018-11-01 00:00:00

  • A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal.

    abstract::Artifacts cause distortion and fuzziness in electroencephalographic (EEG) signal and hamper EEG analysis, so it is necessary to remove them prior to the analysis. Particularly, artifact removal becomes a critical issue in experimental protocols with significant inherent recording noise, such as mobile EEG recordings a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1620-3

    authors: Li J,Chen Y,Taya F,Lim J,Wong K,Sun Y,Bezerianos A

    更新日期:2017-09-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

    abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1458-0

    authors: Halevi R,Hamdan A,Marom G,Lavon K,Ben-Zekry S,Raanani E,Bluestein D,Haj-Ali R

    更新日期:2016-11-01 00:00:00

  • Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

    abstract::An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl cas...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513315

    authors: Goto H,Sugiura T,Harada Y,Kazui T

    更新日期:1999-05-01 00:00:00

  • Development of an eye-movement analyser possessing functions for wireless transmission and autocalibration.

    abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446149

    authors: Yamada M,Fukuda T,Hirota M

    更新日期:1990-07-01 00:00:00

  • Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

    abstract::Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0653-7

    authors: Yang Z,Wickwire AC,Debski RE

    更新日期:2010-11-01 00:00:00

  • Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

    abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0539-8

    authors: Monaghan CC,van Riel WJ,Veltink PH

    更新日期:2009-11-01 00:00:00

  • Motorised resection device for transurethral resection of the prostate: a laboratory evaluation.

    abstract::Transurethral resection of the prostate is the most common method of relieving urinary outflow obstruction secondary to prostatic enlargement. However, this procedure can be responsible for various complications, including irrigant-fluid absorption and blood loss, both of which are strongly dependent on operation dura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510962

    authors: Mestas JL,Cathignol D,Chavrier F,Devonec M

    更新日期:1997-11-01 00:00:00

  • Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

    abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0827-y

    authors: Bousbiat S,Jaffrin MY,Dongmo E

    更新日期:2011-11-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Biomechanical analysis of the muscular power of martial arts athletes.

    abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0608-z

    authors: Machado SM,Osório RA,Silva NS,Magini M

    更新日期:2010-06-01 00:00:00

  • CT-3D rotational angiography automatic registration: a sensitivity analysis.

    abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351041

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Causin F,Colombo F

    更新日期:2005-09-01 00:00:00

  • Effect of radiographic landmark identification errors on the accuracy of three-dimensional reconstruction of the human spine.

    abstract::In three-dimensional reconstruction of the human spine obtained from stereo-radiographic set-ups (two radiographs or more), it is extremely difficult to identify exactly the same landmarks on all radiographs. The effect of these identification errors was investigated with simulations made on points of known three-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446787

    authors: André B,Dansereau J,Labelle H

    更新日期:1992-11-01 00:00:00

  • A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0348-5

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-07-01 00:00:00

  • Pulse transit time based respiratory rate estimation with singular spectrum analysis.

    abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02088-6

    authors: Ding X,Yan BP,Karlen W,Zhang YT,Tsang HK

    更新日期:2020-02-01 00:00:00

  • Recording of physiological signals with domestic videotape storage.

    abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02447101

    authors: Salvador CH,Rosende P,González MA

    更新日期:1991-03-01 00:00:00

  • Robust segmentation and intelligent decision system for cerebrovascular disease.

    abstract::Segmentation and classification of low-quality and noisy ultrasound images is challenging task. In this paper, a new approach is proposed for robust segmentation and classification of carotid artery ultrasound images and consequently, detecting cerebrovascular disease. The proposed technique consists of two phases, in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1481-1

    authors: Chaudhry A,Hassan M,Khan A

    更新日期:2016-12-01 00:00:00

  • Empirical mode decomposition: a method to reduce low frequency interferences from surface electroenterogram.

    abstract::The surface electroenterogram (EEnG) is a non-invasive method of studying myoelectrical bowel activity. However, surface EEnG recordings are contaminated by cardiac activity, respiratory and motion artifacts, and other sources of interference. The aim of this work is to remove the respiration artifact and the very low...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0189-7

    authors: Ye Y,Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2007-06-01 00:00:00

  • Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

    abstract::Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyoc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0164-3

    authors: Ruhparwar A,Er F,Martin U,Radke K,Gruh I,Niehaus M,Karck M,Haverich A,Hoppe UC

    更新日期:2007-02-01 00:00:00