Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

Abstract:

:Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plotting such values in an xy-system, their linear regression is back-projected to intersect the identity line, so yielding an estimated Gp. The objective is to theoretically analyse all possible lines, Ges = aGed + b (Baan's line) and, based on experimental results, to establish their limitations. This was attained by calculating the regression lines using, first Ged = f1(Ges) and thereafter, Ges = f2(Ged), which led to two values, Gp2 and Gp1, for the parallel conductance. The morphology of the saline curve was also modified to assess its effect on the extrapolation. Multiple dilutions were recorded in eight experimental dogs injecting different concentrations. Each curve was classified according to the maximum change (VAR) reached by the total average conductance. Over 138 manoeuvres, 276 regressions were processed yielding correlations higher than 0.65. Of this total, 92.4% gave positive parallel conductances. The rest produced negative values and, thus, were neglected. If the two (Ged, Ges) statistical relationships were ideal, they should yield Gp = Gp1 = Gp2; however, there were differences which, when Gp1 was studied against Gp2, led to: Gp1 = 0.97 Gp2 + 0.055, with r = 0.9476, and n = 85. The remaining 53 were discarded because either some Gp values were negative, or the correlation of Ges which Ged (or vice versa) was < 0.85, and/or VAR < 15%; the two latter conditions were found necessary for reliable calibration. Baan's line high correlation is not a unique condition to ensure the accuracy and precision of Gp determination because the slope a depends on VAR and, thus, different intersections with the identity line may be obtained. Its recommended that manoeuvres be used with at least eight data points, with VAR > 15% and, finally, with (Ges, Ged) correlation better than 0.85. Theoretical analysis of Baan's line offers a reference frame, which contains only a limited number of practical possibilities.

journal_name

Med Biol Eng Comput

authors

Herrera MC,Olivera JM,Valentinuzzi ME

doi

10.1007/BF02513284

keywords:

subject

Has Abstract

pub_date

1999-03-01 00:00:00

pages

169-74

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

37

pub_type

杂志文章
  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • Fluid flow and particle transport in mechanically ventilated airways. Part II: particle transport.

    abstract::The flow mechanisms that play a role on aerosol deposition were identified and presented in a companion paper (Timothy et al. in Med Biol Eng Comput. doi: 10.1007/s11517-015-1407-3 , 2015). In the current paper, the effects of invasive conventional mechanical ventilation waveforms and endotracheal tube (ETT) on the ae...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1408-2

    authors: Alzahrany M,Van Rhein T,Banerjee A,Salzman G

    更新日期:2016-07-01 00:00:00

  • Empirical mode decomposition: a method to reduce low frequency interferences from surface electroenterogram.

    abstract::The surface electroenterogram (EEnG) is a non-invasive method of studying myoelectrical bowel activity. However, surface EEnG recordings are contaminated by cardiac activity, respiratory and motion artifacts, and other sources of interference. The aim of this work is to remove the respiration artifact and the very low...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0189-7

    authors: Ye Y,Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2007-06-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • Inhibition of TNF-alpha induced cell death in human umbilical vein endothelial cells and Jurkat cells by protocatechuic acid.

    abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345308

    authors: Zhou-Stache J,Buettner R,Artmann G,Mittermayer C,Bosserhoff AK

    更新日期:2002-11-01 00:00:00

  • Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

    abstract::The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (P...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0621-2

    authors: Kim HJ,Chun HJ,Moon SH,Kang KT,Kim HS,Park JO,Moon ES,Sohn JS,Lee HM

    更新日期:2010-07-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • Computerised volumetric analysis of lesions in multiple sclerosis using new semi-automatic segmentation software.

    abstract::The paper describes the application of new semi-automatic segmentation software to the task of detection of anatomical structures and lesion and their three-dimensional (3D) visualisation in 23 patients with secondary progressive multiple sclerosis (MS). The purpose is to study the correlation between magnetic resonan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513274

    authors: Dastidar P,Heinonen T,Vahvelainen T,Elovaara I,Eskola H

    更新日期:1999-01-01 00:00:00

  • Spectral analysis of heart rate variability using the integral pulse frequency modulation model.

    abstract::Spectral analysis of heart rate variability (HRV) is a widely accepted approach for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. As a rule, the non-parametric methods for HRV spectral analysis are tested using the integral pulse frequency modulation (IPFM) model. Ho...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345290

    authors: Mitov IP

    更新日期:2001-05-01 00:00:00

  • Activating function of needle electrodes in anisotropic tissue.

    abstract::We present an analytical solution for the electrical potential and activating function (AF) established by cylindrical needle electrodes in anisotropic tissue. We compare this activating function to (1) AF computed assuming line-source electrodes and (2) AF computed using a finite element program. The results show tha...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0508-2

    authors: Guo L,Cranford JP,Neu JC,Neu WK

    更新日期:2009-09-01 00:00:00

  • Multi-parametric cardiorespiratory analysis in late-preterm, early-term, and full-term infants at birth.

    abstract::Infants born at 35-37 weeks' gestational age (GA) are at higher risk for a range of pathological conditions and poorer neurodevelopmental outcomes. However, mechanisms responsible are not fully understood. The purpose of this paper is to use traditional and novel techniques to assess newborn autonomic development as a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1866-4

    authors: Lucchini M,Burtchen N,Fifer WP,Signorini MG

    更新日期:2019-01-01 00:00:00

  • Myocardial perfusion monitoring during coronary artery bypass using an electrocardiogram-triggered laser Doppler technique.

    abstract::Electrocardiogram (ECG)-triggered laser Doppler perfusion monitoring (LDPM) was used to assess myocardial perfusion, with minimum myocardial tissue motion influence, during coronary artery bypass grafting (CABG). Thirteen subjects were investigated at six phases: pre- and post-CABG; post aorta cross-clamping; pre and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351031

    authors: Karlsson MG,Fors C,Wårdell K,Casimir-Ahn H

    更新日期:2005-09-01 00:00:00

  • Classification of basic daily movements using a triaxial accelerometer.

    abstract::A generic framework for the automated classification of human movements using an accelerometry monitoring system is introduced. The framework was structured around a binary decision tree in which movements were divided into classes and subclasses at different hierarchical levels. General distinctions between movements...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347551

    authors: Mathie MJ,Celler BG,Lovell NH,Coster AC

    更新日期:2004-09-01 00:00:00

  • Computational wrist analysis of functional restoration after scapholunate dissociation repair.

    abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01971-6

    authors: Wayne JS,Tremols EJ

    更新日期:2019-07-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • Interface mechanics in external prosthetics: review of interface stress measurement techniques.

    abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02522507

    authors: Sanders JE

    更新日期:1995-07-01 00:00:00

  • Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy.

    abstract::Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing r...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524436

    authors: Buitenweg JR,Rutten WL,Willems WP,van Nieuwkasteele JW

    更新日期:1998-09-01 00:00:00

  • Angular relational signature-based chest radiograph image view classification.

    abstract::In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We presen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1786-3

    authors: Santosh KC,Wendling L

    更新日期:2018-08-01 00:00:00

  • Two-electrode low supply voltage electrocardiogram signal amplifier.

    abstract::Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation, including telemedicine applications. Low-voltage and low-power design tendencies prevail. Modern battery cell voltages in the range of 3-3.6 V require appropriate circuit solutions. A two-electrode biopotentia...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344642

    authors: Dobrev D

    更新日期:2004-03-01 00:00:00

  • French legal framework relating to human tissues and cells.

    abstract::Thousands of patients receive human tissue grafts every year. Developments in cell and tissue engineering have also increased considerably the number of available products of human origin. France has very strict regulations, in part stimulated by problems of public health and ethics that have emerged in recent years a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344783

    authors: Pascal P,Damour O,Colpart JJ,Braye F

    更新日期:2000-03-01 00:00:00

  • Evaluation of divided attention using different stimulation models in event-related potentials.

    abstract::Divided attention is defined as focusing on different tasks at once, and this is described as one of the biggest problems of today's society. Default examinations for understanding attention are questionnaires or physiological signals, like evoked potentials and electroencephalography. Physiological records were obtai...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02013-x

    authors: Batbat T,Güven A,Dolu N

    更新日期:2019-09-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Proposal of hemodynamically improved design of an axial flow blood pump for LVAD.

    abstract::Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02097-5

    authors: Kannojiya V,Das AK,Das PK

    更新日期:2020-02-01 00:00:00

  • Foetal heart rate power spectrum response to uterine contraction.

    abstract::Cardiotocography is the most diffused prenatal diagnostic technique in clinical routine. The simultaneous recording of foetal heart rate (FHR) and uterine contractions (UC) provides useful information about foetal well-being during pregnancy and labour. However, foetal electronic monitoring interpretation still lacks ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0022-8

    authors: Romano M,Bifulco P,Cesarelli M,Sansone M,Bracale M

    更新日期:2006-03-01 00:00:00

  • Real-time human motion estimation using biomechanical models and non-linear state-space filters.

    abstract::In the field of sports biomechanics and rehabilitation engineering, the possibility of computing, in real time, the angular displacements and derivatives of human joints, from a video of motion sequences, represents an appealing goal. In particular, applications of biofeedback protocols in rehabilitation can benefit f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344878

    authors: Cerveri P,Rabuffetti M,Pedotti A,Ferrigno G

    更新日期:2003-03-01 00:00:00

  • Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.

    abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1226-y

    authors: Facchinetti A,Del Favero S,Sparacino G,Cobelli C

    更新日期:2015-12-01 00:00:00

  • Identification of the breast boundary in mammograms using active contour models.

    abstract::A method for the identification of the breast boundary in mammograms is presented. The method can be used in the preprocessing stage of a system for computer-aided diagnosis (CAD) of breast cancer and also in the reduction of image file size in picture archiving and communication system applications. The method starte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344632

    authors: Ferrari RJ,Rangayyan RM,Desautels JE,Borges RA,Frère AF

    更新日期:2004-03-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers.

    abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344773

    authors: Ensell G,Banks DJ,Richards PR,Balachandran W,Ewins DJ

    更新日期:2000-03-01 00:00:00