Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy.

Abstract:

:Sealing resistance is highly significant with respect to the electrical neuron-electrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing resistance on the total impedance spectrum of a cell-electrode interface is modelled for complete coverage of the electrode by the cell. Sensitivity analysis demonstrates that the impedance spectrum is determined by four parameters: two electrode parameters, the sealing resistance and the shunt capacitance between the lead of the electrode and the culture medium. Experimental verification of the model is performed by simultaneous measurement of the impedance spectrum and electrode coverage. A good and unique fit between the simulated and measured impedance spectra was obtained by varying the two electrode parameters and the sealing resistance.

journal_name

Med Biol Eng Comput

authors

Buitenweg JR,Rutten WL,Willems WP,van Nieuwkasteele JW

doi

10.1007/BF02524436

keywords:

subject

Has Abstract

pub_date

1998-09-01 00:00:00

pages

630-7

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

36

pub_type

杂志文章
  • Intelligent prediction of kinetic parameters during cutting manoeuvres.

    abstract::Due to its capabilities in analysing injury risk, the ability to analyse an athlete's ground reaction force and joint moments is of high interest in sports biomechanics. However, using force plates for the kinetic measurements influences the athlete's performance. Therefore, this study aims to use a feed-forward neura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02000-2

    authors: Mundt M,David S,Koeppe A,Bamer F,Markert B,Potthast W

    更新日期:2019-08-01 00:00:00

  • Foetal heart rate power spectrum response to uterine contraction.

    abstract::Cardiotocography is the most diffused prenatal diagnostic technique in clinical routine. The simultaneous recording of foetal heart rate (FHR) and uterine contractions (UC) provides useful information about foetal well-being during pregnancy and labour. However, foetal electronic monitoring interpretation still lacks ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0022-8

    authors: Romano M,Bifulco P,Cesarelli M,Sansone M,Bracale M

    更新日期:2006-03-01 00:00:00

  • Development of an eye-movement analyser possessing functions for wireless transmission and autocalibration.

    abstract::An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent rei...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446149

    authors: Yamada M,Fukuda T,Hirota M

    更新日期:1990-07-01 00:00:00

  • 3D shape analysis to reduce false positives for lung nodule detection systems.

    abstract::Using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), we developed a methodology for classifying lung nodules. The proposed methodology uses image processing and pattern recognition techniques. To classify volumes of interest into nodules and non-nodules, we used shape mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1582-x

    authors: Filho AOC,Silva AC,de Paiva AC,Nunes RA,Gattass M

    更新日期:2017-08-01 00:00:00

  • Fluctuation analysis of respiratory impedance waveform in asthmatic patients: effect of airway obstruction.

    abstract::Fluctuation analysis has great potential to contribute to pulmonary clinical science and practice. We evaluated the relationship between asthma and the respiratory impedance recurrence period density entropy (RPDEnZrs) and the variability (SDZrs). A non-invasive and simple protocol for assessing respiratory mechanics ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0957-x

    authors: Veiga J,Lopes AJ,Jansen JM,Melo PL

    更新日期:2012-12-01 00:00:00

  • Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

    abstract::An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl cas...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513315

    authors: Goto H,Sugiura T,Harada Y,Kazui T

    更新日期:1999-05-01 00:00:00

  • A cepstrum analysis-based classification method for hand movement surface EMG signals.

    abstract::It is of great importance to effectively process and interpret surface electromyogram (sEMG) signals to actuate a robotic and prosthetic exoskeleton hand needed by hand amputees. In this paper, we have proposed a cepstrum analysis-based method for classification of basic hand movement sEMG signals. Cepstral analysis t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02024-8

    authors: Yavuz E,Eyupoglu C

    更新日期:2019-10-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • Application of artificial neural network model combined with four biomarkers in auxiliary diagnosis of lung cancer.

    abstract::The purpose of the study was to explore the application of artificial neural network model in the auxiliary diagnosis of lung cancer and compare the effects of back-propagation (BP) neural network with Fisher discrimination model for lung cancer screening by the combined detections of four biomarkers of p16, RASSF1A a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1585-7

    authors: Duan X,Yang Y,Tan S,Wang S,Feng X,Cui L,Feng F,Yu S,Wang W,Wu Y

    更新日期:2017-08-01 00:00:00

  • Detection of the third heart sound using a tailored wavelet approach: method verification.

    abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345957

    authors: Hult P,Fjällbrant T,Hildén K,Dahlström U,Wranne B,Ask P

    更新日期:2005-03-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Contact mechanics of a thin-walled capsule adhered onto a rigid planar substrate.

    abstract::A thin-walled capsule, modelled as an incompressible liquid droplet contained in a thin flexible membrane, was allowed to adhere onto a rigid substrate. The contact mechanics were formulated, based on linear elasticity, to portray quantitatively the relationships between osmotic inflation, contact area and angle, memb...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345154

    authors: Wan KT,Liu KK

    更新日期:2001-09-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Computer-controlled mechanical lung model for application in pulmonary function studies.

    abstract::A computer controlled mechanical lung model has been developed for testing lung function equipment, validation of computer programs and simulation of impaired pulmonary mechanics. The construction, function and some applications are described. The physical model is constructed from two bellows and a pipe system repres...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523009

    authors: Verbraak AF,Beneken JE,Bogaard JM,Versprille A

    更新日期:1995-11-01 00:00:00

  • A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0348-5

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-07-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • Bivariate nonlinear prediction to quantify the strength of complex dynamical interactions in short-term cardiovascular variability.

    abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0043-3

    authors: Faes L,Nollo G

    更新日期:2006-05-01 00:00:00

  • Multiregional viscoelastic characterization of the corona radiata in the sagittal plane of the porcine brain.

    abstract::Detailed finite element (FE) models are used as promising tools to investigate traumatic brain injuries, although their accuracy is strongly dependent on the characterization of the mechanical behaviors of the different anatomic structures in the brain. In some cases, when the FE models require finer spatial resolutio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1891-3

    authors: Pan C,Chen F,Zhou J,Li X,Zhao F,Zhang X

    更新日期:2019-03-01 00:00:00

  • Subject-specific finite element analysis of a lumbar cage produced by electron beam melting.

    abstract::The aim of this study was the analysis of the mechanical behaviour of a partially porous lumbar custom-made cage by means of a subject-specific finite element analysis (FEA). The cage, made of Ti6Al4V ELI alloy, was produced via electron beam melting (EBM) process and surgically implanted in a female subject, 50 years...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02078-8

    authors: Epasto G,Distefano F,Mineo R,Guglielmino E

    更新日期:2019-12-01 00:00:00

  • Axial head rotation increases facet joint capsular ligament strains in automotive rear impact.

    abstract::Axial head rotation prior to low speed automotive rear impacts has been clinically identified to increase morbidity and symptom duration. The present study was conducted to determine the effect of axial head rotation on facet joint capsule strains during simulated rear impacts. The study was conducted using a validate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0682-2

    authors: Storvik SG,Stemper BD

    更新日期:2011-02-01 00:00:00

  • Computational wrist analysis of functional restoration after scapholunate dissociation repair.

    abstract::The scapholunate ligament stabilizes the scaphoid and lunate of the proximal row in the wrist which allows for proper force transmission with the radius and ulna. Damage to this structure degenerates into arthritis and disability. Controversy exists over the best technique to restore function and reduce pain. A three-...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01971-6

    authors: Wayne JS,Tremols EJ

    更新日期:2019-07-01 00:00:00

  • Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study.

    abstract::A computer-aided method was developed to automatically localize tumors in lung PET images of discrete bins within the breathing cycle, followed by an algorithm that registers all the information of a complete respiratory cycle into a single reference bin. Four registration/integration algorithms: Centroid Based, Inten...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0549-6

    authors: Wang J,del Valle M,Goryawala M,Franquiz JM,McGoron AJ

    更新日期:2010-01-01 00:00:00

  • Apnea bradycardia detection based on new coupled hidden semi Markov model.

    abstract::In this paper, a method for apnea bradycardia detection in preterm infants is presented based on coupled hidden semi Markov model (CHSMM). CHSMM is a generalization of hidden Markov models (HMM) used for modeling mutual interactions among different observations of a stochastic process through using finite number of hi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02277-8

    authors: Montazeri Ghahjaverestan N,Shamsollahi MB,Ge D,Beuchée A,Hernández AI

    更新日期:2021-01-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Theoretical evaluation of a simple cooling pad for inducing hypothermia in the spinal cord following traumatic injury.

    abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0543-z

    authors: Smith KD,Zhu L

    更新日期:2010-02-01 00:00:00

  • Application of mechanical mobility of periodontal tissues to tooth mobility examination.

    abstract::Tooth mobility examination is important in planning dental treatment, as it may give an indication of alveolar bone loss and the condition of the periodontal ligament. In clinical dental diagnosis a manual tooth mobility examination is useful. However, its determination of tooth mobility is subjective and depends on t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442173

    authors: Oka H,Yamamoto T,Saratani K,Kawazoe T

    更新日期:1989-01-01 00:00:00

  • A convolutional neural network-based learning approach to acute lymphoblastic leukaemia detection with automated feature extraction.

    abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02282-x

    authors: Anwar S,Alam A

    更新日期:2020-12-01 00:00:00

  • Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

    abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0394-z

    authors: Jaffrin MY,Morel H

    更新日期:2009-01-01 00:00:00