CT-3D rotational angiography automatic registration: a sensitivity analysis.

Abstract:

:Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel structures to be evaluated three-dimensionally with respect to standard 2D projective angiography. The method for optimising preprocessing, binning and subsampling consisted of independent variation of the corresponding parameters to maximise robustness and speed while maintaining subvoxel accuracy; the latter was computed as the sum of the mean squared errors initially present in the registrations with the errors relative to both binning and subsampling. The results suggest the choice of 256 bins, steps between 14 mm (coarse optimisation) and 2.5 mm (fine optimisation) and bone segmentation by threshold, for binning, subsampling and preprocessing, respectively. The application of this parameter set-up to 50 CT-3DRA registrations resulted in a saving, on average, of 40% of the time with respect to the method previously used, while registration error was maintained within 2 mm (1.97 mm, 90% confidence interval) and robustness was increased, so that no manual initial realignment was needed in 48 registrations. Validation by the registration of images acquired for a head phantom showed subvoxel residual errors. In conclusion, the proposed procedure can be considered a satisfactory strategy to optimise CT-3DRA registration.

journal_name

Med Biol Eng Comput

authors

Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Causin F,Colombo F

doi

10.1007/BF02351041

keywords:

subject

Has Abstract

pub_date

2005-09-01 00:00:00

pages

667-71

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

43

pub_type

杂志文章
  • Relation between branching patterns and perfusion in stochastic generated coronary arterial trees.

    abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0139-9

    authors: Dankelman J,Cornelissen AJ,Lagro J,Vanbavel E,Spaan JA

    更新日期:2007-01-01 00:00:00

  • Plasma detection of NO by a catheter.

    abstract::Nitric oxide (NO) released by endothelial cells in response to hemodynamic shear stress is a key controller molecule of the vascular functions and antiatherogenic mechanisms. Endothelial dysfunction is associated with increased cardiovascular events. Therefore, several indirect techniques have been employed to evaluat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0333-z

    authors: Goto M,Mochizuki S

    更新日期:2008-05-01 00:00:00

  • Dynamic simulation of the natural and replaced human ankle joint.

    abstract::Disappointing results for total ankle replacement have been explained by poor knowledge of the mechanics of the intact and replaced joints. Dynamic simulation tools have the capacity to simulate dynamic conditions that occur in human joints. The Working Model 2D tool was used to simulate the mechanics of the intact an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348124

    authors: Leardini A,Moschella D

    更新日期:2002-03-01 00:00:00

  • A weighted ensemble-based active learning model to label microarray data.

    abstract::Classification of cancerous genes from microarray data is an important research area in bioinformatics. Large amount of microarray data are available, but it is very costly to label them. This paper proposes an active learning model, a semi-supervised classification approach, to label the microarray data using which p...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02238-1

    authors: De R,Chakraborty A,Chatterjee A,Sarkar R

    更新日期:2020-10-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • Continuous cardiac output monitoring system.

    abstract::A continuous cardiac output monitoring system has been developed in the laboratory to allow the real-time measurement of the cardiac output. This form of continuous cardiac output measurement allows the doctor to view the beat-to-beat cardiac output and can be employed to measure artery constrictions as well. The sens...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345272

    authors: Tjin SC,Ho YC,Lam YZ,Hao J,Ng BK

    更新日期:2001-01-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00

  • Dual-sectored transurethral ultrasound for thermal treatment of stress urinary incontinence: in silico studies in 3D anatomical models.

    abstract::The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulation...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02152-6

    authors: Liu D,Adams M,Burdette EC,Diederich CJ

    更新日期:2020-06-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Contact mechanics of a thin-walled capsule adhered onto a rigid planar substrate.

    abstract::A thin-walled capsule, modelled as an incompressible liquid droplet contained in a thin flexible membrane, was allowed to adhere onto a rigid substrate. The contact mechanics were formulated, based on linear elasticity, to portray quantitatively the relationships between osmotic inflation, contact area and angle, memb...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345154

    authors: Wan KT,Liu KK

    更新日期:2001-09-01 00:00:00

  • Computerised volumetric analysis of lesions in multiple sclerosis using new semi-automatic segmentation software.

    abstract::The paper describes the application of new semi-automatic segmentation software to the task of detection of anatomical structures and lesion and their three-dimensional (3D) visualisation in 23 patients with secondary progressive multiple sclerosis (MS). The purpose is to study the correlation between magnetic resonan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513274

    authors: Dastidar P,Heinonen T,Vahvelainen T,Elovaara I,Eskola H

    更新日期:1999-01-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • Inducing therapeutic hypothermia via selective brain cooling: a finite element modeling analysis.

    abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01962-7

    authors: Yin L,Jiang H,Zhao W,Li H

    更新日期:2019-06-01 00:00:00

  • CFD simulations for paper-based DNA amplification reaction (LAMP) of Mycobacterium tuberculosis-point-of-care diagnostic perspective.

    abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02082-y

    authors: Das D,Panigrahi PK

    更新日期:2020-02-01 00:00:00

  • Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability.

    abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344729

    authors: Lange S,Van Leeuwen P,Geue D,Hatzmann W,Grönemeyer D

    更新日期:2005-07-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • A new method for measurement of motor unit action potential duration based on correlation, a pilot study.

    abstract::We present a new, automatic, correlation-based method for measuring the duration of motor unit action potentials (MUAPs). The method seeks to replicate the way an expert elctromyographer uses his or her eyes, calculating the start and end of the MUAP waveform on the basis of the degree of similarity of non-excluded di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02115-6

    authors: Rodríguez Carreño I,Malanda A,Gila Useros L,Gurtubay IG,Navallas J,Rodríguez-Falces J

    更新日期:2020-03-01 00:00:00

  • Pain model and fuzzy logic patient-controlled analgesia in shock-wave lithotripsy.

    abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02347706

    authors: Shieh JS,Chang LW,Wang MS,Sun WZ,Wang YP,Yang YP

    更新日期:2002-01-01 00:00:00

  • Design, construction and evaluation of an ambulatory device for screening of sleep apnea.

    abstract::Obstructive sleep apnea syndrome (OSAS) is a major public health problem. The golden reference for diagnosing OSAS is the sleep-laboratory based polysomnography (PSG). However, screening of population for OSAS may be practical and cost efficient only through ambulatory home recordings. In this work we aimed to design,...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0418-8

    authors: Tiihonen P,Pääkkönen A,Mervaala E,Hukkanen T,Töyräs J

    更新日期:2009-01-01 00:00:00

  • Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics.

    abstract::A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three, as in a normal tricuspid valve (TAV). Although 97 % of BAVs include asymmetric cusps, little or no prior studies have investigated the blood flow through a three-dimensional BAV and root. The aim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1055-4

    authors: Marom G,Kim HS,Rosenfeld M,Raanani E,Haj-Ali R

    更新日期:2013-08-01 00:00:00

  • Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis.

    abstract::Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1359-7

    authors: Gonçalves H,Pinto P,Silva M,Ayres-de-Campos D,Bernardes J

    更新日期:2016-04-01 00:00:00

  • Influence of synchronous and sequential stimulation on muscle fatigue.

    abstract::In acute experiments the sciatic nerve of the rat is electrically stimulated to induce fatigue in the medial Gastrocnemius muscle. Fatigue tests are carried out using intermittent stimulation of different compartments (sequential) or a single compartment (synchronous) of the sciatic nerve. The activation of different ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530036

    authors: Thomsen M,Veltink PH

    更新日期:1997-05-01 00:00:00

  • A comparison of two Hilbert spectral analyses of heart rate variability.

    abstract::The present paper compares the performance of two Hilbert spectral analyses when applied to a synthetic RR series from a nonstationary integral pulse frequency modulation model and to real RR series from a dataset of normal sinus arrhythmia. The Hilbert-Huang transformation based on empirical mode decomposition is com...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0500-x

    authors: Ihlen EA

    更新日期:2009-10-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

    abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1458-0

    authors: Halevi R,Hamdan A,Marom G,Lavon K,Ben-Zekry S,Raanani E,Bluestein D,Haj-Ali R

    更新日期:2016-11-01 00:00:00

  • An adaptive enhancement method for breast X-ray images based on the nonsubsampled contourlet transform domain and whale optimization algorithm.

    abstract::We propose a new method for breast X-ray image adaptive enhancement that combines nonsubsampled contourlet transform (NSCT) with the whale optimization algorithm (WOA). First, the mammography X-ray image was processed by histogram equalization to ensure global image contrast. The processed image was then decomposed in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02022-w

    authors: Zhang CJ,Nie HH

    更新日期:2019-10-01 00:00:00

  • Effect of signal length on the performance of independent component analysis when extracting the lambda wave.

    abstract::The aim of the study was to investigate the effect of signal length on the performance of a signal source separation method, independent component analysis (ICA), when extracting the visual evoked potential (EP) lambda wave from saccade-related electro-encephalogram (EEG) waveforms. A method was devised that enabled t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348134

    authors: Vigon L,Saatchi R,Mayhew JE,Taroyan NA,Frisby JP

    更新日期:2002-03-01 00:00:00