Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

Abstract:

:A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs (n = 18) and humans (n = 5). A resonance of AP closed-loop regulation is found to amplify LF oscillations. In dogs, the resonance gain increases slightly during baroreceptor unloading (mild hypotension obtained with nitroglycerine (NTG) i.v. infusion, n = 8) and coronary artery occlusion ((CAO), n = 6), and it is abolished by ganglionic transmission blockade ((ARF), Arfonad i.v. infusion, n = 3). In humans, this gain is considerably increased by passive tilt. Different, possibly central, sources of LF oscillations are also evaluated, finding a strong rhythmic modulation of HP during CAO. At HF, a direct respiratory arrhythmia is dominant in dogs at control, while it is considerably reduced during CAO. On the contrary, in humans, a strong influence of respiration on AP is shown which induces a reflex respiratory arrhythmia. An index of the gain of baroreceptive response, alpha cl, was decreased by NTG and CAO, and virtually abolished by chronic arterial baroreceptive denervation (TABD, n = 4) and ARF.

journal_name

Med Biol Eng Comput

authors

Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

doi

10.1007/BF02518911

subject

Has Abstract

pub_date

1994-03-01 00:00:00

pages

143-52

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

32

pub_type

杂志文章
  • Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration.

    abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01995-y

    authors: Salman HE,Yazicioglu Y

    更新日期:2019-08-01 00:00:00

  • Inhibition of TNF-alpha induced cell death in human umbilical vein endothelial cells and Jurkat cells by protocatechuic acid.

    abstract::The Chinese herb radix Salviae miltiorrhizae (RSM) is used in traditional Chinese medicine as a treatment for cardiovascular and cerebrovascular diseases. Several components of the plant extract from salvia mitorrhiza bunge have been determined previously, one of which is protocatechuic acid (PAC). It has been found, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345308

    authors: Zhou-Stache J,Buettner R,Artmann G,Mittermayer C,Bosserhoff AK

    更新日期:2002-11-01 00:00:00

  • Clinical applications of musculoskeletal modelling for the shoulder and upper limb.

    abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-013-1099-5

    authors: Bolsterlee B,Veeger DH,Chadwick EK

    更新日期:2013-09-01 00:00:00

  • Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

    abstract::Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyoc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0164-3

    authors: Ruhparwar A,Er F,Martin U,Radke K,Gruh I,Niehaus M,Karck M,Haverich A,Hoppe UC

    更新日期:2007-02-01 00:00:00

  • Computer-controlled positive displacement pump for physiological flow simulation.

    abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446086

    authors: Holdsworth DW,Rickey DW,Drangova M,Miller DJ,Fenster A

    更新日期:1991-11-01 00:00:00

  • A novel recursive Fourier transform for nonuniform sampled signals: application to heart rate variability spectrum estimation.

    abstract::We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0461-0

    authors: Holland A,Aboy M

    更新日期:2009-07-01 00:00:00

  • Extracellular volume measurements using bioimpedance spectroscopy-Hanai method and wrist-ankle resistance at 50 kHz.

    abstract::A method for extrapolating the extracellular water (ECW) resistance from wrist-ankle resistance at 50 kHz (R (50)) is proposed in this paper, in order to enable 50 kHz impedancemeters to use the BIS-Hanai equation for determination of ECW. Values of R (50) and the ECW resistance extrapolated at zero frequency R (e) we...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0394-z

    authors: Jaffrin MY,Morel H

    更新日期:2009-01-01 00:00:00

  • Quantitative video-based gait pattern analysis for hemiparkinsonian rats.

    abstract::Gait disturbances are common in the rat model of Parkinson's disease (PD) by administrating 6-hydroxydopamine. However, few studies have simultaneously assessed spatiotemporal gait indices and the kinematic information of PD rats during overground locomotion. This study utilized a simple, accurate, and reproducible me...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0933-5

    authors: Lee HY,Hsieh TH,Liang JI,Yeh ML,Chen JJ

    更新日期:2012-09-01 00:00:00

  • Quantitative analysis of images in erythropoietin doping control.

    abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345819

    authors: Bajla I,Holländer I,Gmeiner G,Reichel Ch

    更新日期:2005-05-01 00:00:00

  • The Pocket Speech Aid.

    abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441487

    authors: Keating D,Smith DC,Evans AL,Wyper DJ,Cunningham E

    更新日期:1989-05-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Temperature measurement on tissue surface during laser irradiation.

    abstract::Tissue surface temperature distribution on the treatment site can serve as an indicator for the effectiveness of a photothermal therapy. In this study, both infrared thermography and theoretical simulation were used to determine the surface temperature distribution during laser irradiation of both gel phantom and anim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0251-5

    authors: Gnyawali SC,Chen Y,Wu F,Bartels KE,Wicksted JP,Liu H,Sen CK,Chen WR

    更新日期:2008-02-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • ANN compression of morphologically similar ECG complexes.

    abstract::A compression algorithm for electrocardiogram signals is presented, based on an auto-associative neural network. Issues of weight and activation coding are considered, and compression performances of various network sizes are compared. A unique feature is the performance improvement achieved using DC level removal. A ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523019

    authors: Hamilton DJ,Thomson DC,Sandham WA

    更新日期:1995-11-01 00:00:00

  • Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access.

    abstract::Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to ch...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345123

    authors: Mansy HA,Hoxie SJ,Patel NH,Sandler RH

    更新日期:2005-01-01 00:00:00

  • Multiregional viscoelastic characterization of the corona radiata in the sagittal plane of the porcine brain.

    abstract::Detailed finite element (FE) models are used as promising tools to investigate traumatic brain injuries, although their accuracy is strongly dependent on the characterization of the mechanical behaviors of the different anatomic structures in the brain. In some cases, when the FE models require finer spatial resolutio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1891-3

    authors: Pan C,Chen F,Zhou J,Li X,Zhao F,Zhang X

    更新日期:2019-03-01 00:00:00

  • Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    abstract::Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0939-z

    authors: Jo SE,Joung S,Suh JK,Kim YJ

    更新日期:2012-09-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • Theoretical evaluation of a simple cooling pad for inducing hypothermia in the spinal cord following traumatic injury.

    abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0543-z

    authors: Smith KD,Zhu L

    更新日期:2010-02-01 00:00:00

  • Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications.

    abstract::Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline manoeuvre procedure leads to Gp by finding the end-systolic (Ges) and end-diastolic (Ged) conductances, for each beat of the dilution curve rising limb. After plott...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513284

    authors: Herrera MC,Olivera JM,Valentinuzzi ME

    更新日期:1999-03-01 00:00:00

  • Interface mechanics in external prosthetics: review of interface stress measurement techniques.

    abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/BF02522507

    authors: Sanders JE

    更新日期:1995-07-01 00:00:00

  • Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.

    abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1589-3

    authors: Mi Y,Rui S,Li C,Yao C,Xu J,Bian C,Tang X

    更新日期:2017-07-01 00:00:00

  • Cumulant-based trapezoidal basis selection for heart sound classification.

    abstract::Past decades witnessed the expansion of linear signal processing methods in numerous biomedical applications. However, the nonlinear behavior of biomedical signals revived the interest in nonlinear signal processing methods such as higher-order statistics, in particular higher-order cumulants (HOC). In this paper, HOC...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1394-4

    authors: Safara F

    更新日期:2015-11-01 00:00:00

  • Mathematical model of tumor volume dynamics in mice treated with electrochemotherapy.

    abstract::The effectiveness of electrochemotherapy, a local treatment using electric pulses to increase the uptake of chemotherapeutic drug, includes several antitumor mechanisms. In addition to the cytotoxic action of chemotherapeutic drug, treatment outcome also depends on antitumor immune response. In order to assess the con...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1562-1

    authors: Forjanič T,Miklavčič D

    更新日期:2017-07-01 00:00:00

  • Reliable femoral frame construction based on MRI dedicated to muscles position follow-up.

    abstract::In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different seque...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1302-y

    authors: Dubois G,Bonneau D,Lafage V,Rouch P,Skalli W

    更新日期:2015-10-01 00:00:00

  • A mechatronic valve in the management of hydrocephalus: methods and performance.

    abstract::The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0716-9

    authors: Momani L,Al-Nuaimy W,Al-Jumaily M,Mallucci C

    更新日期:2011-01-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • Non-contact diagnostic system for sleep apnea-hypopnea syndrome based on amplitude and phase analysis of thoracic and abdominal Doppler radars.

    abstract::Full-night polysomnography (PSG) has been recognized as the gold standard test for sleep apnea-hypopnea syndrome (SAHS). However, PSG examinees are physically restrained for the full night by many contact sensors and obtrusive connecting cables, inducing mental stress. We developed a non-contact SAHS diagnostic system...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1370-z

    authors: Kagawa M,Tojima H,Matsui T

    更新日期:2016-05-01 00:00:00

  • Single motor unit analysis from spatially filtered surface electromyogram signals. Part 2: conduction velocity estimation.

    abstract::The aim of the study was to compare experimentally conduction velocity (CV) estimates obtained with different estimation methods based on surface electromyogram (EMG) signals detected using five spatial filters. The filters investigated were the longitudinal single and double differential, transverse single and double...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348440

    authors: Schulte E,Farina D,Rau G,Merletti R,Disselhorst-Klug C

    更新日期:2003-05-01 00:00:00