Mechanical and electromotile characteristics of auditory outer hair cells.

Abstract:

:The passive and active properties of the cochlear outer hair cell are studied. The outer hair cell is currently considered the major candidate for the active component of mammalian hearing. Understanding of its properties may explain the amplification and sharp frequency selectivity of the ear. To analyse the cell behaviour, a model of a nonlinear anisotropic electro-elastic shell is used. Using the data from three independent experiments, where the mechanical strains of the cell are measured, estimates of the cell wall in-plane Young's moduli and Poisson's ratios are given, as well as estimates of three modes of bending stiffness. Based on these estimates and data from the microchamber experiment, where the cell is under the action of transmembrane potential changes, the characteristics of the outer hair cell active behaviour are found. These characteristics include the coefficients of the active force production per unit of the transmembrane potential change and limiting parameters of the electromotile response for extreme hyperpolarisation and depolarisation of the cell. The obtained estimates provide important information for the modelling of organ-level cochlear mechanics.

journal_name

Med Biol Eng Comput

authors

Spector AA,Brownell WE,Popel AS

doi

10.1007/BF02513294

keywords:

subject

Has Abstract

pub_date

1999-03-01 00:00:00

pages

247-51

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

37

pub_type

杂志文章
  • Effect of flow direction on the morphological responses of cultured bovine aortic endothelial cells.

    abstract::The effect of flow direction on the morphology of cultured bovine aortic endothelial cells is studied. Fully confluent endothelial cells cultured on glass were subjected to a fluid-imposed shear stress of 2 Pa for 20 min and 24 h using a parallel plate flow chamber. Experiments on shear flow exposure were performed fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522869

    authors: Kataoka N,Ujita S,Sato M

    更新日期:1998-01-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • Fluid flow and particle transport in mechanically ventilated airways. Part II: particle transport.

    abstract::The flow mechanisms that play a role on aerosol deposition were identified and presented in a companion paper (Timothy et al. in Med Biol Eng Comput. doi: 10.1007/s11517-015-1407-3 , 2015). In the current paper, the effects of invasive conventional mechanical ventilation waveforms and endotracheal tube (ETT) on the ae...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1408-2

    authors: Alzahrany M,Van Rhein T,Banerjee A,Salzman G

    更新日期:2016-07-01 00:00:00

  • Modulating effect of respiration on atrioventricular conduction time assessed using PR interval variation.

    abstract::Respiratory sinus arrhythmia (RSA) is the variation of heart rate (or RR interval) in phase with respiration and has been extensively studied. However, the effect of respiration on atrioventricular conduction delay (and hence PR interval length) has not yet received much attention. This work reports on measurements of...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345298

    authors: Shouldice R,Heneghan C,Nolan P,Nolan PG,McNicholas W

    更新日期:2002-11-01 00:00:00

  • Automatic identification of motor unit action potential trains from electromyographic signals using fuzzy techniques.

    abstract::A technique is proposed that allows automatic decomposition of electromyographic (EMG) signals into their constituent motor unit action potential trains (MUAPTs). A specific iterative algorithm with a classification method using fuzzy-logic techniques was developed. The proposed classification method takes into accoun...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02349972

    authors: Chauvet E,Fokapu O,Hogrel JY,Gamet D,Duchêne J

    更新日期:2003-11-01 00:00:00

  • Multiregional viscoelastic characterization of the corona radiata in the sagittal plane of the porcine brain.

    abstract::Detailed finite element (FE) models are used as promising tools to investigate traumatic brain injuries, although their accuracy is strongly dependent on the characterization of the mechanical behaviors of the different anatomic structures in the brain. In some cases, when the FE models require finer spatial resolutio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1891-3

    authors: Pan C,Chen F,Zhou J,Li X,Zhao F,Zhang X

    更新日期:2019-03-01 00:00:00

  • Backflow length predictions during flow-controlled infusions using a nonlinear biphasic finite element model.

    abstract::A previously proposed finite element model that considers geometric and material nonlinearities and the free boundary problems that occur at the catheter tip and in the annular zone around the lateral surface of the catheter was revised and was used to fit a power-law formula to predict backflow length during infusion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1187-1

    authors: Orozco GA,Smith JH,García JJ

    更新日期:2014-10-01 00:00:00

  • Effect of radiographic landmark identification errors on the accuracy of three-dimensional reconstruction of the human spine.

    abstract::In three-dimensional reconstruction of the human spine obtained from stereo-radiographic set-ups (two radiographs or more), it is extremely difficult to identify exactly the same landmarks on all radiographs. The effect of these identification errors was investigated with simulations made on points of known three-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446787

    authors: André B,Dansereau J,Labelle H

    更新日期:1992-11-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • CT analysis of the use of the electrical impedance technique to estimate local oedema in the extremities in patients with lymphatic obstruction.

    abstract::The aim of the study is to establish the validity of the use of the electrical impedance technique for estimating local oedema in extremities through comparison with computed-tomography (CT) analysis. Eight healthy women (group 1) and nine women with unilateral leg oedema following chronic lymphatic obstruction (group...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522859

    authors: Watanabe R,Kotoura H,Morishita Y

    更新日期:1998-01-01 00:00:00

  • Classification of the long-QT syndrome based on discriminant analysis of T-wave morphology.

    abstract::The long QT syndrome (LQTS) is a genetic disorder, typically characterized by a prolonged QT interval in the ECG due to abnormal cardiac repolarization. LQTS may lead to syncopal episodes and sudden cardiac death. Various parameters based on T-wave morphology, as well as the QT interval itself have been shown to be us...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0061-1

    authors: Struijk JJ,Kanters JK,Andersen MP,Hardahl T,Graff C,Christiansen M,Toft E

    更新日期:2006-07-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits.

    abstract::Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal is compared with simultaneously determined, coloured microsphere (CM)-derived standardised M...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02520078

    authors: Bray R,Forrester K,McDougall JJ,Damji A,Ferrell WR

    更新日期:1996-05-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Delineation of the ischemic stroke lesion based on watershed and relative fuzzy connectedness in brain MRI.

    abstract::Precise segmentation of stroke lesions from brain magnetic resonance (MR) images poses a challenging task in automated diagnosis. In this paper, we proposed a new method called watershed-based lesion segmentation algorithm (WLSA), which is a novel intensity-based segmentation technique used to delineate infarct lesion...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1726-7

    authors: Subudhi A,Jena S,Sabut S

    更新日期:2018-05-01 00:00:00

  • Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

    abstract::Dislocation is a serious potential complication of total hip replacement. Previous studies have proposed a newly developed total hip structure that meets the required oscillation angle of 120°, for which the chamfer on the acetabular liner rim was designed to enable the neck to impinge on the chamfer over a large area...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1673-3

    authors: Chi WM,Lin CC,Ho YJ,Lin HC,Chen JH

    更新日期:2018-01-01 00:00:00

  • Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    abstract::The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a lo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1256-0

    authors: Akça K,Eser A,Çavuşoğlu Y,Sağırkaya E,Çehreli MC

    更新日期:2015-05-01 00:00:00

  • Analysis and decomposition of signals obtained by thigh-fixed uni-axial accelerometry during normal walking.

    abstract::The use of piezo-resistive uni-axial accelerometer signals in gait analysis is complicated by the fact that the measured signal is composed of different types of acceleration. The aim of the study is to obtain insight into the signal from a tangential accelerometer attached to the thigh during walking. Six subjects wa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344868

    authors: Bussmann JB,Damen L,Stam HJ

    更新日期:2000-11-01 00:00:00

  • Prognostic factors in the prediction of chronic wound healing by electrical stimulation.

    abstract::The aim of the study is to determine the effects of wound, patient and treatment attributes on the wound healing rate and to propose a system for wound healing rate prediction. Predicting the wound healing rate from the initial wound, patient and treatment data collected in a database of 300 chronic wounds is not poss...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345144

    authors: Cukjati D,Robnik-Sikonja M,Rebersek S,Kononenko I,Miklavcic D

    更新日期:2001-09-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Application of artificial neural network model combined with four biomarkers in auxiliary diagnosis of lung cancer.

    abstract::The purpose of the study was to explore the application of artificial neural network model in the auxiliary diagnosis of lung cancer and compare the effects of back-propagation (BP) neural network with Fisher discrimination model for lung cancer screening by the combined detections of four biomarkers of p16, RASSF1A a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1585-7

    authors: Duan X,Yang Y,Tan S,Wang S,Feng X,Cui L,Feng F,Yu S,Wang W,Wu Y

    更新日期:2017-08-01 00:00:00

  • Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis.

    abstract::This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0349-4

    authors: Dobbe JG,Streekstra GJ,Atasever B,van Zijderveld R,Ince C

    更新日期:2008-07-01 00:00:00

  • Increase in intrathoracic volume in pectus excavatum patients after the Nuss procedure.

    abstract::In this study, we present finite element analysis models to calculate the increase in intrathoracic volume of pectus excavatum patients after the Nuss procedure. One virtue of our approach is that the measurement of the intrathoracic volume has no time difference and is not affected by postoperative pain, which cannot...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0570-9

    authors: Chang PY,Hsu ZY,Lai JY,Wang CJ,Ching YT

    更新日期:2010-02-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

    abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0539-8

    authors: Monaghan CC,van Riel WJ,Veltink PH

    更新日期:2009-11-01 00:00:00

  • Proposal of hemodynamically improved design of an axial flow blood pump for LVAD.

    abstract::Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02097-5

    authors: Kannojiya V,Das AK,Das PK

    更新日期:2020-02-01 00:00:00

  • Displacement of alveolar macrophages in air space of human lung.

    abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522517

    authors: Gradoń L,Podgórski A

    更新日期:1995-07-01 00:00:00

  • A multi-command SSVEP-based BCI system based on single flickering frequency half-field steady-state visual stimulation.

    abstract::Steady-state visual evoked potentials (SSVEPs) are widely employed in brain-computer interface (BCI) applications, especially to control machines. However, the use of SSVEPs leads to eye fatigue and causes lower accuracy over the long term, particularly when multi-commands are required. Therefore, this paper proposes ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1560-3

    authors: Punsawad Y,Wongsawat Y

    更新日期:2017-06-01 00:00:00

  • Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

    abstract::A simple inertial measurement unit (IMU) incorporating rate gyroscopes and accelerometers has been tested to investigate the trunk kinematics during the sit-to-stand. It was affixed at trunk L5 level and used for sit-to-stand position and orientation reconstruction. The method was validated with standard optoelectroni...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0224-8

    authors: Giansanti D,Maccioni G,Benvenuti F,Macellari V

    更新日期:2007-10-01 00:00:00