Automatic identification of motor unit action potential trains from electromyographic signals using fuzzy techniques.

Abstract:

:A technique is proposed that allows automatic decomposition of electromyographic (EMG) signals into their constituent motor unit action potential trains (MUAPTs). A specific iterative algorithm with a classification method using fuzzy-logic techniques was developed. The proposed classification method takes into account imprecise information, such as waveform instability and irregular firing patterns, that is often encountered in EMG signals. Classification features were determined by the combining of time position and waveform information. Statistical analysis of inter-pulse intervals and spike amplitude provided an accurate estimation of features used in the classification step. Algorithm performance was evaluated using simulated EMG signals composed of up to six different discharging motor units corrupted with white noise. The algorithm was then applied to real signals recorded by a high spatial resolution surface EMG device based on a Laplacian spatial filter. On six groups of 20 simulated signals, the decomposition algorithm performed with a maximum and an average mean error rate of 2.13% and 1.37%, respectively. On real surface EMG signals recorded at different force levels (from 10% to 40% of the maximum voluntary contraction), the algorithm correctly identified 21 MUAPTs, compared with the 29 MUAPTs identified by an experienced neurophysiologist. The efficiency of the decomposition on surface EMG signals makes this method very attractive for non-invasive investigation of physiological muscle properties. However, it can also be used to decompose intramuscularly recorded EMG signals.

journal_name

Med Biol Eng Comput

authors

Chauvet E,Fokapu O,Hogrel JY,Gamet D,Duchêne J

doi

10.1007/BF02349972

keywords:

subject

Has Abstract

pub_date

2003-11-01 00:00:00

pages

646-53

issue

6

eissn

0140-0118

issn

1741-0444

journal_volume

41

pub_type

杂志文章
  • A new software scheme for scatter correction based on a simple radiographic scattering model.

    abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1893-1

    authors: Kim K,Kang S,Kim W,Park C,Lee D,Cho H,Kang W,Park S,Kim G,Lim H,Lee H,Park J,Jeon D,Lim Y,Woo T,Oh J

    更新日期:2019-02-01 00:00:00

  • Interpreting magnetic fields of the brain: minimum norm estimates.

    abstract::The authors have applied estimation theory to the problem of determining primary current distributions from measured neuromagnetic fields. In this procedure, essentially nothing is assumed about the source currents, except that they are spatially restricted to a certain region. Simulation experiments show that the res...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512476

    authors: Hämäläinen MS,Ilmoniemi RJ

    更新日期:1994-01-01 00:00:00

  • Clinical evaluation of 430 MHz microwave hyperthermia system with lens applicator for cancer therapy.

    abstract::The clinical efficacy of a microwave (MW) hyperthermia system using an electric-field converging (lens) applicator is evaluated for 42 malignant tumours with a maximum tumour depth of less than 7 cm. The mean of the maximum, average and minimum tumour temperature of the 42 tumours are 44.5, 42.5 and 40.7 C, respective...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02522944

    authors: Hiraoka M,Nishimura Y,Masunaga S,Koishi M,Mitsumori M,Li YP,Nagata Y,Akuta K,Takahashi M,Abe M

    更新日期:1995-01-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • PC/VAX or standalone PC-based general purpose biological data collection system.

    abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446881

    authors: Marlow SP,Mackenzie DA,Tomlinson JB

    更新日期:1993-01-01 00:00:00

  • Pain model and fuzzy logic patient-controlled analgesia in shock-wave lithotripsy.

    abstract::Pain control in conscious patients was investigated using a push-button, demand-driven supply of drugs. A fuzzy logic patient-controlled analgesia (PCA) algorithm was compared with a conventional algorithm, for alfentanil administration in extracorporeal shock-wave lithotripsy. The conventional PCA algorithm used an i...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02347706

    authors: Shieh JS,Chang LW,Wang MS,Sun WZ,Wang YP,Yang YP

    更新日期:2002-01-01 00:00:00

  • Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

    abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s11517-006-0036-2

    authors: Madeleine P,Ge HY,Jaskólska A,Farina D,Jaskólski A,Arendt-Nielsen L

    更新日期:2006-04-01 00:00:00

  • Interaction between steady flow and individualised compliant segments: application to upper airways.

    abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510972

    authors: Fodil R,Ribreau C,Louis B,Lofaso F,Isabey D

    更新日期:1997-11-01 00:00:00

  • Selective laser sintering in biomedical engineering.

    abstract::Selective laser sintering (SLS) is a solid freeform fabrication technique, developed by Carl Deckard for his master's thesis at the University of Texas, patented in 1989. SLS manufacturing is a technique that produces physical models through a selective solidification of a variety of fine powders. SLS technology is ge...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-012-1001-x

    authors: Mazzoli A

    更新日期:2013-03-01 00:00:00

  • Performance evaluation of ISFETs and other ISE sensors for whole blood ion assay.

    abstract::Performance evaluations of ion-selective field-effect transistors (ISFETs) have been carried out using both quality-control materials and whole arterial blood samples. Comparison of the results from these evaluations suggests that the whole blood evaluation may be more useful when assessing the value of particular sen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442678

    authors: Thompson JM

    更新日期:1990-05-01 00:00:00

  • Comparison of heart rate variability spectra using generic relationships of their input signals.

    abstract::Spectral analysis of heart rate variability (HRV) is an accepted method for assessment of cardiac autonomic function and its relationship to numerous disorders and diseases. Various non-parametric methods for HRV estimation have been developed. The spectrum of counts, the instantaneous heart rate spectrum and the inte...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524426

    authors: Mitov IP,Daskalov IK

    更新日期:1998-09-01 00:00:00

  • Clinical application of modified bag-of-features coupled with hybrid neural-based classifier in dengue fever classification using gene expression data.

    abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1722-y

    authors: Chatterjee S,Dey N,Shi F,Ashour AS,Fong SJ,Sen S

    更新日期:2018-04-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays.

    abstract::This work addresses the problem of estimating the conduction velocity (CV) of single motor unit (MU) action potentials from surface EMG signals detected with linear electrode arrays during voluntary muscle contractions. In ideal conditions, that is without shape or scale changes of the propagating signals and with add...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344807

    authors: Farina D,Muhammad W,Fortunato E,Meste O,Merletti R,Rix H

    更新日期:2001-03-01 00:00:00

  • Electrotactile perception of scatterplots on the fingertips and abdomen.

    abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345967

    authors: Haase SJ,Kaczmarek KA

    更新日期:2005-03-01 00:00:00

  • Exactness of source analysis of biomagnetic signals of epileptiform spikes by the method of spatial filtering: a computer simulation.

    abstract::On the basis of spatial covariance it is found that, by spatial filtering the localisation of a single dipole source, both parallel and perpendicular to the measurement plane (assuming a signal-noise ratio of 5:1), can be performed with an accuracy of < 0.5 mm. When the signal-noise ratio is increased to 30:1, the res...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510982

    authors: Wagner H,Eiselt M,Zwiener U

    更新日期:1997-11-01 00:00:00

  • Thermal distribution analysis of three-dimensional tumor-embedded breast models with different breast density compositions.

    abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1403-7

    authors: Wahab AA,Salim MI,Ahamat MA,Manaf NA,Yunus J,Lai KW

    更新日期:2016-09-01 00:00:00

  • Enrichment of cardiac pacemaker-like cells: neuregulin-1 and cyclic AMP increase I(f)-current density and connexin 40 mRNA levels in fetal cardiomyocytes.

    abstract::Generation of a large number of cells belonging to the cardiac pacemaker system would constitute an important step towards their utilization as a biological cardiac pacemaker system. The aim of the present study was to identify factors, which might induce transformation of a heterogenous population of fetal cardiomyoc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0164-3

    authors: Ruhparwar A,Er F,Martin U,Radke K,Gruh I,Niehaus M,Karck M,Haverich A,Hoppe UC

    更新日期:2007-02-01 00:00:00

  • Effect of flow disturbances remaining at the beginning of diastole on intraventricular diastolic flow and colour M-mode Doppler echocardiograms.

    abstract::A computational model of the fluid dynamics of intraventricular flow was used to investigate the importance of the effects of flow disturbances existing within the left ventricle (LV) at the onset of diastole on a diastolic flow field. The simulation started with a quiescent flow state; it continued for a number of ca...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02350992

    authors: Nakamura M,Wada S,Mikami T,Kitabatake A,Karino T,Yamaguchi T

    更新日期:2004-07-01 00:00:00

  • Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

    abstract::Multi-scale modeling of the musculoskeletal system plays an essential role in the deep understanding of complex mechanisms underlying the biological phenomena and processes such as bone metabolic processes. Current multi-scale models suffer from the isolation of sub-models at each anatomical scale. The objective of th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-016-1572-z

    authors: Dao TT

    更新日期:2017-06-01 00:00:00

  • The analysis of forces needed for the suturing of elliptical skin wounds.

    abstract::There is a lack of information regarding the forces required for suturing human wounds. The knowledge of suturing forces serves as complementary information for setting up the limiting geometry when using tissue adhesives and it might also be used in robot-assisted surgery. The main purpose of this paper was to evalua...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0857-5

    authors: Capek L,Jacquet E,Dzan L,Simunek A

    更新日期:2012-02-01 00:00:00

  • Axial head rotation increases facet joint capsular ligament strains in automotive rear impact.

    abstract::Axial head rotation prior to low speed automotive rear impacts has been clinically identified to increase morbidity and symptom duration. The present study was conducted to determine the effect of axial head rotation on facet joint capsule strains during simulated rear impacts. The study was conducted using a validate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0682-2

    authors: Storvik SG,Stemper BD

    更新日期:2011-02-01 00:00:00

  • A novel fused convolutional neural network for biomedical image classification.

    abstract::With the advent of biomedical imaging technology, the number of captured and stored biomedical images is rapidly increasing day by day in hospitals, imaging laboratories and biomedical institutions. Therefore, more robust biomedical image analysis technology is needed to meet the requirement of the diagnosis and class...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1819-y

    authors: Pang S,Du A,Orgun MA,Yu Z

    更新日期:2019-01-01 00:00:00

  • Multiregional viscoelastic characterization of the corona radiata in the sagittal plane of the porcine brain.

    abstract::Detailed finite element (FE) models are used as promising tools to investigate traumatic brain injuries, although their accuracy is strongly dependent on the characterization of the mechanical behaviors of the different anatomic structures in the brain. In some cases, when the FE models require finer spatial resolutio...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1891-3

    authors: Pan C,Chen F,Zhou J,Li X,Zhao F,Zhang X

    更新日期:2019-03-01 00:00:00

  • Biphasic model of the trabecular meshwork in the eye.

    abstract::A biphasic continuum model for the flow of intraocular fluid, the aqueous humour, in the trabecular meshwork is proposed in the paper. The model considers the meshwork as a circular ring with uniform thickness of homogeneous, isotropic, viscoelastic material swollen with continuously percolating aqueous humour. The mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446710

    authors: Tandon PN,Autar R

    更新日期:1991-05-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Biomechanical analysis of the muscular power of martial arts athletes.

    abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0608-z

    authors: Machado SM,Osório RA,Silva NS,Magini M

    更新日期:2010-06-01 00:00:00

  • Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability.

    abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344729

    authors: Lange S,Van Leeuwen P,Geue D,Hatzmann W,Grönemeyer D

    更新日期:2005-07-01 00:00:00

  • Influence of synchronous and sequential stimulation on muscle fatigue.

    abstract::In acute experiments the sciatic nerve of the rat is electrically stimulated to induce fatigue in the medial Gastrocnemius muscle. Fatigue tests are carried out using intermittent stimulation of different compartments (sequential) or a single compartment (synchronous) of the sciatic nerve. The activation of different ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530036

    authors: Thomsen M,Veltink PH

    更新日期:1997-05-01 00:00:00

  • Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

    abstract::Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0653-7

    authors: Yang Z,Wickwire AC,Debski RE

    更新日期:2010-11-01 00:00:00