Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Abstract:

:Dislocation is a serious potential complication of total hip replacement. Previous studies have proposed a newly developed total hip structure that meets the required oscillation angle of 120°, for which the chamfer on the acetabular liner rim was designed to enable the neck to impinge on the chamfer over a large area after impingement occurs. This study adopted the finite element method to further analyse the torque limits leading to dislocation and the contact stresses at the impingement and egress sites of the liner during subluxation. The compressive stress-strain curve for ultra-high molecular weight polyethylene is nonlinear. The results reveal that an adequate chamfer angle of the acetabular cup liner can significantly increase dislocation torque and decrease contact stress on the liner rim. By means of the new design, when the head-neck ratio (HNR) is 2.5 or 3.0, the maximum torque value that a 36-mm head can withstand is 1.38 (8.7 Nm/6.3 Nm) or 1.47 (8.4 Nm/5.7 Nm) times that of a 22-mm head, while the maximum stress of a 36-mm head is 0.41 (14.58 MPa/35.73 MPa) or 0.70 (33.71 MPa/47.90 MPa) times that of a 22-mm head. When the head diameters are identical, the dislocation torque of the HNR = 2.5 structure is slightly greater than that of the HNR = 3.0 structure (3.3-10.5%); thus, the newly developed structure can disperse contact stress, and the structure of a large head with a low HNR exhibits a higher dislocation torque value and lower stress.

journal_name

Med Biol Eng Comput

authors

Chi WM,Lin CC,Ho YJ,Lin HC,Chen JH

doi

10.1007/s11517-017-1673-3

subject

Has Abstract

pub_date

2018-01-01 00:00:00

pages

37-47

issue

1

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-017-1673-3

journal_volume

56

pub_type

杂志文章
  • Automatic selection and feature extraction of motor-evoked potentials by transcranial magnetic stimulation in stroke patients.

    abstract::Transcranial magnetic stimulation (TMS) allows the assessment of stroke patients' cortical excitability and corticospinal tract integrity, which provide information regarding motor function recovery. However, the extraction of features from motor-evoked potentials (MEP) elicited by TMS, such as amplitude and latency, ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-021-02315-z

    authors: Tecuapetla-Trejo JE,Cantillo-Negrete J,Carrillo-Mora P,Valdés-Cristerna R,Ortega-Robles E,Arias-Carrion O,Carino-Escobar RI

    更新日期:2021-01-26 00:00:00

  • Evaluation of feature extraction techniques and classifiers for finger movement recognition using surface electromyography signal.

    abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1857-5

    authors: Phukpattaranont P,Thongpanja S,Anam K,Al-Jumaily A,Limsakul C

    更新日期:2018-12-01 00:00:00

  • Modulating effect of respiration on atrioventricular conduction time assessed using PR interval variation.

    abstract::Respiratory sinus arrhythmia (RSA) is the variation of heart rate (or RR interval) in phase with respiration and has been extensively studied. However, the effect of respiration on atrioventricular conduction delay (and hence PR interval length) has not yet received much attention. This work reports on measurements of...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345298

    authors: Shouldice R,Heneghan C,Nolan P,Nolan PG,McNicholas W

    更新日期:2002-11-01 00:00:00

  • Displacement of alveolar macrophages in air space of human lung.

    abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522517

    authors: Gradoń L,Podgórski A

    更新日期:1995-07-01 00:00:00

  • Electrotactile perception of scatterplots on the fingertips and abdomen.

    abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345967

    authors: Haase SJ,Kaczmarek KA

    更新日期:2005-03-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • A new software scheme for scatter correction based on a simple radiographic scattering model.

    abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1893-1

    authors: Kim K,Kang S,Kim W,Park C,Lee D,Cho H,Kang W,Park S,Kim G,Lim H,Lee H,Park J,Jeon D,Lim Y,Woo T,Oh J

    更新日期:2019-02-01 00:00:00

  • Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

    abstract::The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344888

    authors: Watakabe M,Mita K,Akataki K,Ito K

    更新日期:2003-03-01 00:00:00

  • The formation of extracellular potentials over the innervation zone: Are these potentials affected by changes in fibre membrane properties?

    abstract::Widespread misconceptions still exist regarding the formation of extracellular potentials over the innervation zone: the assumption (1) that the first phase of these potentials mainly reflects the process of initiation of the intracellular action potential (IAP) at the neuromuscular junction and that (2) these potenti...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1487-8

    authors: Rodriguez-Falces J

    更新日期:2016-12-01 00:00:00

  • Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.

    abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1182-6

    authors: Jeon M,Kim J,Kim C

    更新日期:2016-03-01 00:00:00

  • Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

    abstract::An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl cas...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513315

    authors: Goto H,Sugiura T,Harada Y,Kazui T

    更新日期:1999-05-01 00:00:00

  • Evaluation of divided attention using different stimulation models in event-related potentials.

    abstract::Divided attention is defined as focusing on different tasks at once, and this is described as one of the biggest problems of today's society. Default examinations for understanding attention are questionnaires or physiological signals, like evoked potentials and electroencephalography. Physiological records were obtai...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02013-x

    authors: Batbat T,Güven A,Dolu N

    更新日期:2019-09-01 00:00:00

  • Ictal and peri-ictal changes in cervical vagus nerve activity associated with cardiac effects.

    abstract::The vagus nerves convey both afferent and efferent information about autonomic activity related to cardiovascular functions. Those functions have been shown to change due to epileptic seizures, which suggests that ictal events might be detected via the vagus electroneurogram (VENG). In this study, we characterize the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0782-7

    authors: Harreby KR,Sevcencu C,Struijk JJ

    更新日期:2011-09-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.

    abstract::Instantaneous backflow through central clearance of bileaflet heart valves at the instant of closure is investigated. An Edwards-Duromedics valve in the mitral position is employed to measure the transient pressures near the entrance and exit region in an in vitro flow chamber. A region surrounding the clearance is mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510497

    authors: Lee CS,Chandran KB

    更新日期:1995-05-01 00:00:00

  • Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis.

    abstract::Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1359-7

    authors: Gonçalves H,Pinto P,Silva M,Ayres-de-Campos D,Bernardes J

    更新日期:2016-04-01 00:00:00

  • Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop.

    abstract::In a previous paper we demonstrated that the linear portion of the pressure-velocity loop (PU-loop) corresponding to early systole could be used to calculate the local wave speed. In this paper we extend this work to show that determination of the time at which the PU-loop first deviates from linearity provides a conv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0241-7

    authors: Khir AW,Swalen MJ,Feng J,Parker KH

    更新日期:2007-12-01 00:00:00

  • EEG artifacts reduction by multivariate empirical mode decomposition and multiscale entropy for monitoring depth of anaesthesia during surgery.

    abstract::Electroencephalography (EEG) has been widely utilized to measure the depth of anaesthesia (DOA) during operation. However, the EEG signals are usually contaminated by artifacts which have a consequence on the measured DOA accuracy. In this study, an effective and useful filtering algorithm based on multivariate empiri...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1598-2

    authors: Liu Q,Chen YF,Fan SZ,Abbod MF,Shieh JS

    更新日期:2017-08-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

    abstract::Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0873-0

    authors: Arbabi E,Schmid J,Boulic R,Thalmann D,Magnenat-Thalmann N

    更新日期:2012-06-01 00:00:00

  • Registration and geometric modelling of the spine during scoliosis surgery: a comparison study of different pre-operative reconstruction techniques and intra-operative tracking systems.

    abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513328

    authors: Mac-Thiong JM,Aubin CE,Dansereau J,de Guise JA,Brodeur P,Labelle H

    更新日期:1999-07-01 00:00:00

  • Towards a patient-specific hepatic arterial modeling for microspheres distribution optimization in SIRT protocol.

    abstract::Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1703-1

    authors: Simoncini C,Jurczuk K,Reska D,Esneault S,Nunes JC,Bellanger JJ,Saint-Jalmes H,Rolland Y,Eliat PA,Bézy-Wendling J,Kretowski M

    更新日期:2018-03-01 00:00:00

  • Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques.

    abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0694-y

    authors: Zheng D,Amoore JN,Mieke S,Murray A

    更新日期:2011-01-01 00:00:00

  • Rheological modelling of leukocytes.

    abstract::A three-layer Newtonian model is investigated using a combined Eulerian-Lagrangian computational method to describe the dynamic behaviour of leukocytes. The model, composed of a cell membrane (outer layer), cytoplasm (middle layer) and nucleus (inner layer), can better describe the recovery characteristics because lar...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510753

    authors: Tran-Son-Tay R,Kan HC,Udaykumar HS,Damay E,Shyy W

    更新日期:1998-03-01 00:00:00

  • Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre models.

    abstract::Neuronal excitability is determined in a complex way by several interacting factors, such as membrane dynamics, fibre geometry, electrode configuration, myelin impedance, neuronal terminations[Formula: see text] This study aims to increase understanding in excitability, by investigating the impact of these factors on ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1799-y

    authors: Tarnaud T,Joseph W,Martens L,Tanghe E

    更新日期:2018-09-01 00:00:00

  • Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect.

    abstract::The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferrom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345312

    authors: Han BH,Lee SY,Kim JH,Yi JH

    更新日期:2003-09-01 00:00:00

  • Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

    abstract::In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0972-y

    authors: Liao YL,Lu CF,Wu CT,Lee JD,Lee ST,Sun YN,Wu YT

    更新日期:2013-02-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • Duchenne muscular dystrophy quantification: a multivariate analysis of surface EMG.

    abstract::The paper describes a method of quantifying Duchenne muscular dystrophy which is examiner independent and uses surface electromyographic signals (EMG). A standardised protocol is proposed. Spectral parameters are first computed from digitised EMG, then a polynomial model is deduced from the evolution of each parameter...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446966

    authors: Priez A,Duchene J,Goubel F

    更新日期:1992-05-01 00:00:00

  • Estimating germinability of Plasmopara viticola oospores by means of neural networks.

    abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344698

    authors: Vercesi A,Sirtori C,Vavassori A,Setti E,Liberati D

    更新日期:2000-01-01 00:00:00