Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

Abstract:

:Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip joint center of rotation on the results acquired from hip simulation. For this reason, we use three dimensional models of hip tissues reconstructed from MRI datasets of 10 subjects, and estimate their center of rotation by applying five different methods (including both predictive and functional approaches). Then, we calculate the amount of angular and radial penetrations that happen among three dimensional meshes of cartilages, labrum, and femur bone, when hip is rotating about different estimated centers of rotation. The results indicate that hip simulation can be highly affected by the method used for estimating hip center of rotation. However, under some conditions (e.g. when Adduction or External Rotation are considered) we can expect to have a more robust simulation. In addition, it was observed that applying some methods (e.g. the predictive approach based on acetabulum) may result in less robust simulation, comparing to the other methods.

journal_name

Med Biol Eng Comput

authors

Arbabi E,Schmid J,Boulic R,Thalmann D,Magnenat-Thalmann N

doi

10.1007/s11517-012-0873-0

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

595-604

issue

6

eissn

0140-0118

issn

1741-0444

journal_volume

50

pub_type

杂志文章
  • Clinical applications of musculoskeletal modelling for the shoulder and upper limb.

    abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-013-1099-5

    authors: Bolsterlee B,Veeger DH,Chadwick EK

    更新日期:2013-09-01 00:00:00

  • Synergistic effects of local temperature enhancements on cellular responses in the context of high-intensity, ultrashort electric pulses.

    abstract::Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0745-z

    authors: Song J,Joshi RP,Schoenbach KH

    更新日期:2011-06-01 00:00:00

  • Bivariate nonlinear prediction to quantify the strength of complex dynamical interactions in short-term cardiovascular variability.

    abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0043-3

    authors: Faes L,Nollo G

    更新日期:2006-05-01 00:00:00

  • A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

    abstract::In this study, we introduce a novel simulation technique to incorporate delineation errors into radiotherapy treatment margins and combine them with organ motion and set-up errors to investigate the cumulative dosimetric effects in different tumour sites. The effects of applying patient realignment correction protocol...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0616-z

    authors: Mzenda B,Hosseini-Ashrafi M,Palmer A,Liu H,Brown DJ

    更新日期:2010-07-01 00:00:00

  • Three-dimensional changes of the cytoskeleton of vascular endothelial cells exposed to sustained hydrostatic pressure.

    abstract::The three-dimensional changes in the cytoskeleton and in cell proliferation of bovine pulmonary artery endothelial cells when exposed to sustained hydrostatic pressure were investigated in vitro using laser scanning confocal microscopy. Subconfluent endothelial cells on rigid substrates were exposed to 1.5, 5 and 10 c...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523225

    authors: Salwen SA,Szarowski DH,Turner JN,Bizios R

    更新日期:1998-07-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

    abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0827-y

    authors: Bousbiat S,Jaffrin MY,Dongmo E

    更新日期:2011-11-01 00:00:00

  • Gabor filters and phase portraits for the detection of architectural distortion in mammograms.

    abstract::Architectural distortion is a subtle abnormality in mammograms, and a source of overlooking errors by radiologists. Computer-aided diagnosis (CAD) techniques can improve the performance of radiologists in detecting masses and calcifications; however, most CAD systems have not been designed to detect architectural dist...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0088-3

    authors: Rangayyan RM,Ayres FJ

    更新日期:2006-10-01 00:00:00

  • A convolutional neural network-based learning approach to acute lymphoblastic leukaemia detection with automated feature extraction.

    abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02282-x

    authors: Anwar S,Alam A

    更新日期:2020-12-01 00:00:00

  • CFD simulations for paper-based DNA amplification reaction (LAMP) of Mycobacterium tuberculosis-point-of-care diagnostic perspective.

    abstract::Loop-mediated isothermal amplification or LAMP has been identified to be an efficient technology for point-of-care diagnostics. Paper-based LAMP technique has tremendous potential in replacing the existing tube-based technology as the manufacturing cost of a paper-based device is comparatively lower and easy-to-use. L...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02082-y

    authors: Das D,Panigrahi PK

    更新日期:2020-02-01 00:00:00

  • Generation of dynamic random-element stereograms in real time with a system based on a personal computer.

    abstract::A new system capable of generating static and dynamic random-element stereograms is designed and implemented. The stereogram is composed of a rectangle that can be varied in size, element density, orientation, and horizontal and vertical disparities, and can be swept at several velocities. The system is based on an in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524687

    authors: Gonzalez F,Krause F

    更新日期:1994-07-01 00:00:00

  • Noninvasive measurement of blood glucose concentrations by analysing Fourier transform infra-red absorbance spectra through oral mucosa.

    abstract::Whether Fourier transform infra-red spectroscopy with an attenuated total reflection prism could be applied for noninvasive glucose measurement through oral mucosa was evaluated. As a result, the same absorbance peak at 1033 cm-1 as in glucose aqueous solution was found in the absorbance spectra through mucous membran...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446645

    authors: Kajiwara K,Uemura T,Kishikawa H,Nishida K,Hashiguchi Y,Uehara M,Sakakida M,Ichinose K,Shichiri M

    更新日期:1993-07-01 00:00:00

  • Use of surface potential spectral characteristics for solving the inverse problem in electroneurography.

    abstract::The changes in the power spectra of single-fibre extracellular action potentials (SFEAPs) generated in an infinite anisotropic frequency-dependent volume conductor, which occurred as a result of alterations in the propagation velocity v and duration T(in) of the intracellular action potential (IAP) were analytically d...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446167

    authors: Dimitrov GV,Lateva ZC,Dimitrova NA

    更新日期:1992-07-01 00:00:00

  • Corrected formula for estimating peripheral blood flow by impedance plethysmography.

    abstract::In this paper, the limitations of the conventional formula for the computation of peripheral blood flow from impedance plethysmograms are highlighted, and a correction to the formula is suggested. A conductivity cell experiment is described to show the dependence of the value of the blood flow index (BFI), obtained fr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02524237

    authors: Jindal GD,Nerurkar SN,Pednekar SA,Babu JP,Bhuta AC,Deshpande AK

    更新日期:1994-11-01 00:00:00

  • Reliable femoral frame construction based on MRI dedicated to muscles position follow-up.

    abstract::In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different seque...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1302-y

    authors: Dubois G,Bonneau D,Lafage V,Rouch P,Skalli W

    更新日期:2015-10-01 00:00:00

  • Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration.

    abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01995-y

    authors: Salman HE,Yazicioglu Y

    更新日期:2019-08-01 00:00:00

  • Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability.

    abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344729

    authors: Lange S,Van Leeuwen P,Geue D,Hatzmann W,Grönemeyer D

    更新日期:2005-07-01 00:00:00

  • Thermal distribution analysis of three-dimensional tumor-embedded breast models with different breast density compositions.

    abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1403-7

    authors: Wahab AA,Salim MI,Ahamat MA,Manaf NA,Yunus J,Lai KW

    更新日期:2016-09-01 00:00:00

  • Combination of "generalized Trotter operator splitting" and "quadratic adaptive algorithm" method for tradeoff among speedup, stability, and accuracy in the Markov chain model of sodium ion channels in the ventricular cell model.

    abstract::The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo's quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to improve the tradeoff b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02220-x

    authors: Chen XJ,Luo CH,Chen MH

    更新日期:2020-09-01 00:00:00

  • Outlining the prostate boundary using the harmonics method.

    abstract::In a computerised ultrasound image guidance for automated prostatectomy system, it is necessary to identify a smooth, continuous contour for the prostate (boundary) from the ultrasound image. The radial bas-relief (RBR) method, which has been reported previously, can extract a skeletonised image from an ultrasound ima...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518882

    authors: Kwoh CK,Teo MY,Ng WS,Tan SN,Jones LM

    更新日期:1998-11-01 00:00:00

  • Urinary bladder volume tracking using a Kalman filter.

    abstract::This study introduced the Kalman filter procedure for tracking urinary bladder filling from intermittent bladder volume measurements taken by an ultrasonic bladder volume monitor. The Kalman filter was based on a double integrator as a model for the bladder filling process between micturitions and included a procedure...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345809

    authors: Kristiansen NK,Sjöström SO,Nygaard H

    更新日期:2005-05-01 00:00:00

  • Spatio-spectral filters for low-density surface electromyographic signal classification.

    abstract::In this paper, we proposed to utilize a novel spatio-spectral filter, common spatio-spectral pattern (CSSP), to improve the classification accuracy in identifying intended motions based on low-density surface electromyography (EMG). Five able-bodied subjects and a transradial amputee participated in an experiment of e...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1024-3

    authors: Huang G,Zhang Z,Zhang D,Zhu X

    更新日期:2013-05-01 00:00:00

  • Propagation of pacemaker activity.

    abstract::Spontaneous activity of specific regions (e.g., the Sinoatrial node, SAN) is essential for the normal activation sequence of the heart and also serve as a primary means of modulating cardiac rate by sympathetic tone and circulating catecholamines. The mechanisms of how a small SAN region can electrically drive a much ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-006-0102-9

    authors: Joyner RW,Wilders R,Wagner MB

    更新日期:2007-02-01 00:00:00

  • Two-electrode low supply voltage electrocardiogram signal amplifier.

    abstract::Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation, including telemedicine applications. Low-voltage and low-power design tendencies prevail. Modern battery cell voltages in the range of 3-3.6 V require appropriate circuit solutions. A two-electrode biopotentia...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344642

    authors: Dobrev D

    更新日期:2004-03-01 00:00:00

  • Determining appropriate models for joint control using surface electrical stimulation of soleus in spinal cord injury.

    abstract::The mechanical impedance of the ankle joint during electrical stimulation of the soleus is studied by applying constant-velocity 10 degrees angular perturbations to the ankle and measuring the resultant torque. Both neurologically intact subjects and spinal cord injured subjects are tested. Lumped, piecewise linear mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512522

    authors: Flaherty B,Robinson C,Agarwal G

    更新日期:1994-05-01 00:00:00

  • Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.

    abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1182-6

    authors: Jeon M,Kim J,Kim C

    更新日期:2016-03-01 00:00:00

  • Reexamination of risk criteria in dengue patients using the self-organizing map.

    abstract::Even though the World Health Organization criteria's for classifying the dengue infection have been used for long time, recent studies declare that several difficulties have been faced by the clinicians to apply these criteria. Accordingly, many studies have proposed modified criteria to identify the risk in dengue pa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0561-x

    authors: Faisal T,Taib MN,Ibrahim F

    更新日期:2010-03-01 00:00:00

  • Feature extraction for on-line EEG classification using principal components and linear discriminants.

    abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02522476

    authors: Lugger K,Flotzinger D,Schlögl A,Pregenzer M,Pfurtscheller G

    更新日期:1998-05-01 00:00:00

  • CT-3D rotational angiography automatic registration: a sensitivity analysis.

    abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351041

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Causin F,Colombo F

    更新日期:2005-09-01 00:00:00

  • A machine learning approach for magnetic resonance image-based mouse brain modeling and fast computation in controlled cortical impact.

    abstract::Computational modeling of the brain is crucial for the study of traumatic brain injury. An anatomically accurate model with refined details could provide the most accurate computational results. However, computational models with fine mesh details could take prolonged computation time that impedes the clinical transla...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02262-1

    authors: Lai C,Chen Y,Wang T,Liu J,Wang Q,Du Y,Feng Y

    更新日期:2020-11-01 00:00:00