Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect.

Abstract:

:The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferromagnetic structure have been studied. Finite element method analysis results are presented for the effect of size, depth and magnetic saturation of the ferromagnetic structure on the stimulation coil performance. The experimental results show that the stimulation coil performance is improved by up to 40% by the attaching of a ferromagnetic structure on the coil.

journal_name

Med Biol Eng Comput

authors

Han BH,Lee SY,Kim JH,Yi JH

doi

10.1007/BF02345312

keywords:

subject

Has Abstract

pub_date

2003-09-01 00:00:00

pages

516-8

issue

5

eissn

0140-0118

issn

1741-0444

journal_volume

41

pub_type

杂志文章
  • Investigation into the effects of haematocrit and temperature on the resistivity of mammalian blood using a four-electrode probe.

    abstract::Haematocrit and temperature effects on resistivity are investigated using the electrical impedance method. Measurements are made extensively for pig's blood. The experimental set-up basically involves four ring electrodes being placed around a wooden probe that is subsequently immersed into a syringe containing pig's ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523215

    authors: Tjin SC,Xie T,Lam YZ

    更新日期:1998-07-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Evaluating the relationship of non-phase locked activities in the electroencephalogram during intermittent stimulation: a partial coherence-based approach.

    abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0191-0

    authors: Miranda de Sá AM,Infantosi AF

    更新日期:2007-07-01 00:00:00

  • Performance evaluation of ISFETs and other ISE sensors for whole blood ion assay.

    abstract::Performance evaluations of ion-selective field-effect transistors (ISFETs) have been carried out using both quality-control materials and whole arterial blood samples. Comparison of the results from these evaluations suggests that the whole blood evaluation may be more useful when assessing the value of particular sen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442678

    authors: Thompson JM

    更新日期:1990-05-01 00:00:00

  • Automatic lesion segmentation and classification of hepatic echinococcosis using a multiscale-feature convolutional neural network.

    abstract::Hepatic echinococcosis (HE) is a life-threatening liver disease caused by parasites that requires a precise diagnosis and proper treatments. To assess HE lesions accurately, we propose a novel automatic HE lesion segmentation and classification network that contains lesion region positioning (LRP) and lesion region se...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02126-8

    authors: Xin S,Shi H,Jide A,Zhu M,Ma C,Liao H

    更新日期:2020-03-01 00:00:00

  • Biomechanical analysis of structural deformation in living cells.

    abstract::Most tissues are subject to some form of physiological mechanical loading which results in deformation of the cells triggering intracellular mechanotransduction pathways. This response to loading is generally essential for the health of the tissue, although more pronounced deformation may result in cell and tissue dam...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-008-0381-4

    authors: Bader DL,Knight MM

    更新日期:2008-10-01 00:00:00

  • A new combination: scale-space filtering of projected brain activities.

    abstract::In the present study, well known scale-space filtering (SSF) algorithm is used in combination with a linear mapping approach (LMA) to obtain clear auditory evoked potential (EP) waveform. The proposed combination involves two sequential steps: At first, the EEG noise level is reduced from -5 to 0 dB owing to the LMA b...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0450-3

    authors: Aydin S

    更新日期:2009-04-01 00:00:00

  • Evaluation of range of motion restriction within the hip joint.

    abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1016-3

    authors: Turley GA,Williams MA,Wellings RM,Griffin DR

    更新日期:2013-04-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • Bivariate nonlinear prediction to quantify the strength of complex dynamical interactions in short-term cardiovascular variability.

    abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0043-3

    authors: Faes L,Nollo G

    更新日期:2006-05-01 00:00:00

  • Modelling the effect of insulin on the disposal of meal-attributable glucose in type 1 diabetes.

    abstract::The management of postprandial glucose excursions in type 1 diabetes has a major impact on overall glycaemic control. In this work, we propose and evaluate various mechanistic models to characterize the disposal of meal-attributable glucose. Sixteen young volunteers with type 1 diabetes were subject to a variable-targ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1509-6

    authors: García-García F,Hovorka R,Wilinska ME,Elleri D,Hernando ME

    更新日期:2017-02-01 00:00:00

  • Quantitative analysis of images in erythropoietin doping control.

    abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345819

    authors: Bajla I,Holländer I,Gmeiner G,Reichel Ch

    更新日期:2005-05-01 00:00:00

  • Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

    abstract::Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid-structure interaction...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1458-0

    authors: Halevi R,Hamdan A,Marom G,Lavon K,Ben-Zekry S,Raanani E,Bluestein D,Haj-Ali R

    更新日期:2016-11-01 00:00:00

  • Wireless and inductively powered implant for measuring electrocardiogram.

    abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-007-0264-0

    authors: Riistama J,Väisänen J,Heinisuo S,Harjunpää H,Arra S,Kokko K,Mäntylä M,Kaihilahti J,Heino P,Kellomäki M,Vainio O,Vanhala J,Lekkala J,Hyttinen J

    更新日期:2007-12-01 00:00:00

  • Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

    abstract::Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0653-7

    authors: Yang Z,Wickwire AC,Debski RE

    更新日期:2010-11-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Methods of dynamic spectral analysis by self-exciting autoregressive moving average models and their application to analysing biosignals.

    abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510536

    authors: Schack B,Bareshova E,Grieszbach G,Witte H

    更新日期:1995-05-01 00:00:00

  • Effective identification and localization of immature precursors in bone marrow biopsy.

    abstract::Abnormal localization of immature precursors (ALIP) aggregating and clustering in bone marrow biopsy appears earlier than that of bone marrow smears in detection of the relapse of acute myelocytic leukemia (AML). But traditional manual ALIP recognition has many shortcomings such as prone to false alarms, neglect of di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1223-1

    authors: Cao G,Li L,Chen W,Yu Y,Shi J,Zhang G,Liu X

    更新日期:2015-03-01 00:00:00

  • "Hippocrates-mst": a prototype for computer-aided microcalcification analysis and risk assessment for breast cancer.

    abstract::One of the most common cancer types among women is breast cancer. Regular mammographic examinations increase the possibility for early diagnosis and treatment and significantly improve the chance of survival for patients with breast cancer. Clustered microcalcifications have been considered as important indicators of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0117-2

    authors: Spyrou G,Kapsimalakou S,Frigas A,Koufopoulos K,Vassilaros S,Ligomenides P

    更新日期:2006-11-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Estimation of habituation and signal-to-noise ratio of cortical evoked potentials to oesophageal electrical and mechanical stimulation.

    abstract::Electrical and mechanical stimulation of the oesophagus has been recently proposed to examine the physiological effects of autonomic stimulation in humans. Cortical evoked potentials (EPs) to oesophageal stimulation provide an assessment of afferent fibres and central processing. However, habituation takes place durin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02534088

    authors: Kamath MV,Tougas G,Hollerbach S,Premji R,Fitzpatrick D,Shine G,Upton AR

    更新日期:1997-07-01 00:00:00

  • Hybrid finite elements and spectral method for computation of the electric potential generated by a nerve cuff electrode.

    abstract::An original numerical method is developed to compute the 3D electric potential generated by a dot-contact cuff electrode implanted around an axisymmetrical, inhomogeneous, anisotropic nerve. The technique is based on a 2D finite-element approach coupled with a semi-analytical Fourier spectral decomposition to approxim...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513375

    authors: Parrini S,Delbeke J,Romero E,Legat V,Veraart C

    更新日期:1999-11-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Axial head rotation increases facet joint capsular ligament strains in automotive rear impact.

    abstract::Axial head rotation prior to low speed automotive rear impacts has been clinically identified to increase morbidity and symptom duration. The present study was conducted to determine the effect of axial head rotation on facet joint capsule strains during simulated rear impacts. The study was conducted using a validate...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0682-2

    authors: Storvik SG,Stemper BD

    更新日期:2011-02-01 00:00:00

  • Resolving superimposed motor unit action potentials.

    abstract::A new algorithm to resolve superimposed motor unit action potentials (MUAPs) is described, which uses a reduced search space and is based on the peel off approach. Knowledge specific to the problem domain, such as temporal relationships between and within motor unit action potential trains and MUAP energy information,...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02637020

    authors: Etawil H,Stashuk D

    更新日期:1996-01-01 00:00:00

  • Efficient and robust estimation of blood oxygenation levels in single cerebral veins.

    abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0886-8

    authors: Dagher J,Du YP

    更新日期:2012-05-01 00:00:00

  • Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

    abstract::A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518911

    authors: Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

    更新日期:1994-03-01 00:00:00

  • A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

    abstract::A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (nor...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1101-2

    authors: Johnston BM,Johnston PR

    更新日期:2013-12-01 00:00:00

  • Statistical processing for gastric slow-wave identification.

    abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345076

    authors: Grant MS,Williams RD

    更新日期:2002-07-01 00:00:00

  • Biphasic model of the trabecular meshwork in the eye.

    abstract::A biphasic continuum model for the flow of intraocular fluid, the aqueous humour, in the trabecular meshwork is proposed in the paper. The model considers the meshwork as a circular ring with uniform thickness of homogeneous, isotropic, viscoelastic material swollen with continuously percolating aqueous humour. The mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446710

    authors: Tandon PN,Autar R

    更新日期:1991-05-01 00:00:00