A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

Abstract:

:A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (normal), in both the extracellular and intracellular domains, which leads to six conductivity values. To match experimental studies, such a method must be able to determine these six conductivity values, not just the four where it is assumed that the transverse and normal conductivities are equal. This study presents a mathematical model, solution technique, multi-electrode array and two-pass inversion method, which can be used to retrieve all six conductivities from measurements of electrical potential made on the array. Simulated measurements of potential, to which noise is added, are used to demonstrate the ability of the method to retrieve the conductivity values. It is found that not only is it possible to accurately retrieve all six conductivity values, as well as a value for fibre rotation angle, but that the accuracy of such retrievals is comparable to the accuracy found in a previous study when only four conductivities (and fibre rotation) were retrieved.

journal_name

Med Biol Eng Comput

authors

Johnston BM,Johnston PR

doi

10.1007/s11517-013-1101-2

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

1295-303

issue

12

eissn

0140-0118

issn

1741-0444

journal_volume

51

pub_type

杂志文章
  • Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

    abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02511245

    authors: Zhang S,Wright G,Kingston MA,Rolfe P

    更新日期:1996-07-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position.

    abstract::Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implan...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02235-4

    authors: Stadnyk M,Liu T,Arezodar FF,Westover L,Carvajal Alba JA,Masson E,Beaupre L,Jaremko JL,El-Rich M

    更新日期:2020-10-01 00:00:00

  • The Pocket Speech Aid.

    abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441487

    authors: Keating D,Smith DC,Evans AL,Wyper DJ,Cunningham E

    更新日期:1989-05-01 00:00:00

  • Obtaining accurate and calibrated coil models for transcranial magnetic stimulation using magnetic field measurements.

    abstract::Currently, simulations of the induced currents in the brain produced by transcranial magnetic stimulation (TMS) are used to elucidate the regions reached by stimuli. However, models commonly found in the literature are too general and neglect imperfections in the windings. Aiming to predict the stimulation sites in pa...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02156-2

    authors: Mancino AV,Milano FE,Bertuzzi FM,Yampolsky CG,Ritacco LE,Risk MR

    更新日期:2020-07-01 00:00:00

  • Prototype algorithm for automated determination of gastric slow wave characteristics.

    abstract::An algorithm for determining the frequency and propagation time of the gastric slow wave has been designed for integration into a demand gastric pacing system. The algorithm analyses the serosal activity in both the time and frequency domains, and the results are compared to produce a conclusion only when the values a...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344688

    authors: Gray MB,Williams RD,Chen JD

    更新日期:2000-01-01 00:00:00

  • Modeling the effect of tilting, passive leg exercise, and functional electrical stimulation on the human cardiovascular system.

    abstract::Long periods of bed rest negatively affect the human body organs, notably the cardiovascular system. To avert these negative effects and promote functional recovery in patients dealing with prolonged bed rest, the goal is to mobilize them as early as possible while controlling and stabilizing their cardiovascular syst...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1628-8

    authors: Sarabadani Tafreshi A,Okle J,Klamroth-Marganska V,Riener R

    更新日期:2017-09-01 00:00:00

  • Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humans.

    abstract::The interactions between respiration, heart rate and blood pressure variability (HRV, BPV), are considered to be of paramount importance for the study of the functional organisation of the autonomic nervous system (ANS). The aim of the reported study is to detect and classify the intermittent phase locking (PL) phenom...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345011

    authors: Censi F,Calcagnini G,Lino S,Seydnejad SR,Kitney RI,Cerutti S

    更新日期:2000-07-01 00:00:00

  • Inducing therapeutic hypothermia via selective brain cooling: a finite element modeling analysis.

    abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01962-7

    authors: Yin L,Jiang H,Zhao W,Li H

    更新日期:2019-06-01 00:00:00

  • Analysis and decision based on specialist self-assessment for prognosis factors of acute leukemia integrating data-driven Bayesian network and fuzzy cognitive map.

    abstract::The purpose of the present study is to analyze the prognostic factors of acute leukemia and to construct a decision model based on a causal relationship between the factors of this disease to assist medical specialists. In medical decisions, to reach effective, quick, and reliable results, there is a need for a simple...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02267-w

    authors: Jahangoshai Rezaee M,Sadatpour M,Ghanbari-Ghoushchi N,Fathi E,Alizadeh A

    更新日期:2020-11-01 00:00:00

  • Visualisation method of spatial interictal discharges in temporal epilepsy patients using magneto-encephalogram.

    abstract::The aim of the study was to develop a method for investigating how interictal epileptic discharges in temporal epilepsy patients are activated spatially. The activity was measured using magneto-encephalography (MEG). The MEG data were used to produce a current-arrow map that reflected the topographic distribution of t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344215

    authors: Kandori A,Oe H,Miyashita K,Date H,Yamada N,Naritomi H,Chiba Y,Murakami M,Miyashita T,Tsukada K

    更新日期:2002-05-01 00:00:00

  • Angular relational signature-based chest radiograph image view classification.

    abstract::In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We presen...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1786-3

    authors: Santosh KC,Wendling L

    更新日期:2018-08-01 00:00:00

  • Comparison between human awake, meditation and drowsiness EEG activities based on directed transfer function and MVDR coherence methods.

    abstract::This study examined the electroencephalogram functional connectivity (coherence) and effective connectivity (flow of information) of selected brain regions during three different attentive states: awake, meditation and drowsiness. For the estimation of functional connectivity (coherence), Welch and minimum variance di...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1272-0

    authors: Dissanayaka C,Ben-Simon E,Gruberger M,Maron-Katz A,Sharon H,Hendler T,Cvetkovic D

    更新日期:2015-07-01 00:00:00

  • Evaluation of range of motion restriction within the hip joint.

    abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-1016-3

    authors: Turley GA,Williams MA,Wellings RM,Griffin DR

    更新日期:2013-04-01 00:00:00

  • Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation.

    abstract::Uniaxial stress-strain data were obtained from in vitro experiments on 20 porcine livers for compressions, elongations and cycles of compression and then elongation. There were about 70 cylindrical samples, with diameter 7mm and varying height (4-11 mm). The combined compression and elongation test provide a unified f...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345212

    authors: Chui C,Kobayashi E,Chen X,Hisada T,Sakuma I

    更新日期:2004-11-01 00:00:00

  • A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

    abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02101-y

    authors: Ilhan HO,Sigirci IO,Serbes G,Aydin N

    更新日期:2020-05-01 00:00:00

  • Non-contact diagnostic system for sleep apnea-hypopnea syndrome based on amplitude and phase analysis of thoracic and abdominal Doppler radars.

    abstract::Full-night polysomnography (PSG) has been recognized as the gold standard test for sleep apnea-hypopnea syndrome (SAHS). However, PSG examinees are physically restrained for the full night by many contact sensors and obtrusive connecting cables, inducing mental stress. We developed a non-contact SAHS diagnostic system...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1370-z

    authors: Kagawa M,Tojima H,Matsui T

    更新日期:2016-05-01 00:00:00

  • Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability.

    abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344729

    authors: Lange S,Van Leeuwen P,Geue D,Hatzmann W,Grönemeyer D

    更新日期:2005-07-01 00:00:00

  • Laser reflectance imaging of human organs and comparison with perfusion images.

    abstract::Based on the principle of backscattering of laser radiation from tissues, a non-invasive PC-AT based reflectance imaging technique is developed. The laser beam from a semiconductor laser operating at 670 nm is guided to the tissue site by an optical fibre. The backscattered radiation is collected by another fibre plac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02530046

    authors: Shanthi S,Singh M

    更新日期:1997-05-01 00:00:00

  • Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop.

    abstract::In a previous paper we demonstrated that the linear portion of the pressure-velocity loop (PU-loop) corresponding to early systole could be used to calculate the local wave speed. In this paper we extend this work to show that determination of the time at which the PU-loop first deviates from linearity provides a conv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0241-7

    authors: Khir AW,Swalen MJ,Feng J,Parker KH

    更新日期:2007-12-01 00:00:00

  • Theoretical study of the effect of local flow disturbances on the concentration of low-density lipoproteins at the luminal surface of end-to-end anastomosed vessels.

    abstract::To elucidate the mechanisms of localisation of intimal hyperplasia in anastomosed arteries, the effects of flow disturbances on the transport of low-density lipoproteins (LDLs) from the flowing blood to the wall of end-to-end anastomosed arteries, with and without a moderate stenosis, were studied theoretically by mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345458

    authors: Wada S,Koujiya M,Karino T

    更新日期:2002-09-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Adaptive feature extraction for EEG signal classification.

    abstract::One challenge in the current research of brain-computer interfaces (BCIs) is how to classify time-varying electroencephalographic (EEG) signals as accurately as possible. In this paper, we address this problem from the aspect of updating feature extractors and propose an adaptive feature extractor, namely adaptive com...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0107-4

    authors: Sun S,Zhang C

    更新日期:2006-10-01 00:00:00

  • Finite element modeling of the growth plate in a detailed spine model.

    abstract::Very few computer models of the spine integrate vertebral growth plates to investigate their mechanical behavior and potential impacts on bone growth. An approach was developed to generate a finite element (FE) model of the lumbar spine and their connective tissues including the growth plate, which allowed a personali...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0220-z

    authors: Sylvestre PL,Villemure I,Aubin CE

    更新日期:2007-10-01 00:00:00

  • Methods of dynamic spectral analysis by self-exciting autoregressive moving average models and their application to analysing biosignals.

    abstract::Dynamic methods in the spectral domain are necessary to analyse biological signals because of the frequently nonstationary character of the signals. The paper presents an adaptive procedure of fitting time-dependent ARMA models to nonstationary signals, which is suitable for on-line calculations. The properties of the...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510536

    authors: Schack B,Bareshova E,Grieszbach G,Witte H

    更新日期:1995-05-01 00:00:00

  • Quantitative assessment of lower limbs gross motor function in children with cerebral palsy based on surface EMG and inertial sensors.

    abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02076-w

    authors: Chen X,Wu Q,Tang L,Cao S,Zhang X,Chen X

    更新日期:2020-01-01 00:00:00

  • Estimating normal and pathological dynamic responses in cerebral blood flow velocity to step changes in end-tidal pCO2.

    abstract::The regulation of cerebral blood flow (CBF) following changes in arterial blood pressure (ABP) and end-tidal pCO2 (EtCO2) are of clinical interest in assessing cerebrovascular reserve capacity. Linear finite-impulse-response modelling is applied to ABP, EtCO2 and CBF velocity (CBFV, from transcranial Doppler measureme...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345749

    authors: Simpson DM,Panerai RB,Evans DH,Garnham J,Naylor AR,Bell PR

    更新日期:2000-09-01 00:00:00

  • Measurements of steady turbulent flow through a rigid simulated collapsed tube.

    abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345363

    authors: Bertram CD,Muller M,Ramus F,Nugent AH

    更新日期:2001-07-01 00:00:00

  • Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    abstract::Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1559-9

    authors: Shah A,Coste J,Lemaire JJ,Taub E,Schüpbach WMM,Pollo C,Schkommodau E,Guzman R,Hemm-Ode S

    更新日期:2017-05-01 00:00:00

  • Biphasic model of the trabecular meshwork in the eye.

    abstract::A biphasic continuum model for the flow of intraocular fluid, the aqueous humour, in the trabecular meshwork is proposed in the paper. The model considers the meshwork as a circular ring with uniform thickness of homogeneous, isotropic, viscoelastic material swollen with continuously percolating aqueous humour. The mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446710

    authors: Tandon PN,Autar R

    更新日期:1991-05-01 00:00:00