A multi-command SSVEP-based BCI system based on single flickering frequency half-field steady-state visual stimulation.

Abstract:

:Steady-state visual evoked potentials (SSVEPs) are widely employed in brain-computer interface (BCI) applications, especially to control machines. However, the use of SSVEPs leads to eye fatigue and causes lower accuracy over the long term, particularly when multi-commands are required. Therefore, this paper proposes a half-field steady-state visual stimulation pattern and paradigm to increase the limited number of commands that can be achieved with existing SSVEP-based BCI methods. Following the theory of vision perception and existing half-field SSVEP-based BCI systems, the new stimulation pattern generates four commands using only one frequency flickering stimulus and has an average classification accuracy of approximately 75 %. According to the proposed stimulus pattern, using only one frequency without requiring users to stare directly at the flickering stimulus allows users to easily focus on the system and experience less visual fatigue compared to existing systems. Furthermore, new half-field SSVEP-based BCI systems are proposed, incorporating our proposed feature extraction and decision-making algorithm. Extracting the signal from the occipital area and using a reference electrode position at the parietal area yielded better results compared to the central area. In addition, we recommend using an LED or LCD as the visual stimulus device (at the recommended size), which yielded comparable results to our proposed feature extraction and decision-making algorithm. Finally, an application of the proposed system is demonstrated for real-time television control.

journal_name

Med Biol Eng Comput

authors

Punsawad Y,Wongsawat Y

doi

10.1007/s11517-016-1560-3

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

965-977

issue

6

eissn

0140-0118

issn

1741-0444

pii

10.1007/s11517-016-1560-3

journal_volume

55

pub_type

杂志文章
  • Inducing therapeutic hypothermia via selective brain cooling: a finite element modeling analysis.

    abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01962-7

    authors: Yin L,Jiang H,Zhao W,Li H

    更新日期:2019-06-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Varying ultrasound power level to distinguish surgical instruments and tissue.

    abstract::We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1695-x

    authors: Ren H,Anuraj B,Dupont PE

    更新日期:2018-03-01 00:00:00

  • Motorised resection device for transurethral resection of the prostate: a laboratory evaluation.

    abstract::Transurethral resection of the prostate is the most common method of relieving urinary outflow obstruction secondary to prostatic enlargement. However, this procedure can be responsible for various complications, including irrigant-fluid absorption and blood loss, both of which are strongly dependent on operation dura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510962

    authors: Mestas JL,Cathignol D,Chavrier F,Devonec M

    更新日期:1997-11-01 00:00:00

  • Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS).

    abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518872

    authors: Ishikawa N,Suda S,Sasaki T,Yamanishi T,Hosaka H,Yasuda K,Ito H

    更新日期:1998-11-01 00:00:00

  • Pressures generated by rib cage and abdominal compressions during cardiopulmonary resuscitation.

    abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441676

    authors: Ben-Haim SA,Shofti R,Dinnar U,Saidel GM

    更新日期:1990-01-01 00:00:00

  • Clinical application of modified bag-of-features coupled with hybrid neural-based classifier in dengue fever classification using gene expression data.

    abstract::Dengue fever detection and classification have a vital role due to the recent outbreaks of different kinds of dengue fever. Recently, the advancement in the microarray technology can be employed for such classification process. Several studies have established that the gene selection phase takes a significant role in ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1722-y

    authors: Chatterjee S,Dey N,Shi F,Ashour AS,Fong SJ,Sen S

    更新日期:2018-04-01 00:00:00

  • Control of triceps surae stimulation based on shank orientation using a uniaxial gyroscope during gait.

    abstract::This article presents a stimulation control method using a uniaxial gyroscope measuring angular velocity of the shank in the sagittal plane, to control functional electrical stimulation of the triceps surae to improve push-off of stroke subjects during gait. The algorithm is triggered during each swing phase of gait w...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0539-8

    authors: Monaghan CC,van Riel WJ,Veltink PH

    更新日期:2009-11-01 00:00:00

  • Bivariate nonlinear prediction to quantify the strength of complex dynamical interactions in short-term cardiovascular variability.

    abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0043-3

    authors: Faes L,Nollo G

    更新日期:2006-05-01 00:00:00

  • Activating function of needle electrodes in anisotropic tissue.

    abstract::We present an analytical solution for the electrical potential and activating function (AF) established by cylindrical needle electrodes in anisotropic tissue. We compare this activating function to (1) AF computed assuming line-source electrodes and (2) AF computed using a finite element program. The results show tha...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0508-2

    authors: Guo L,Cranford JP,Neu JC,Neu WK

    更新日期:2009-09-01 00:00:00

  • Design and application of sensor for recording sounds over human eye and nose.

    abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523031

    authors: Journée HL,van Bruggen AC,van der Meer JJ,de Jonge AB,Mooij JJ

    更新日期:1995-03-01 00:00:00

  • Interpreting magnetic fields of the brain: minimum norm estimates.

    abstract::The authors have applied estimation theory to the problem of determining primary current distributions from measured neuromagnetic fields. In this procedure, essentially nothing is assumed about the source currents, except that they are spatially restricted to a certain region. Simulation experiments show that the res...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02512476

    authors: Hämäläinen MS,Ilmoniemi RJ

    更新日期:1994-01-01 00:00:00

  • A new software scheme for scatter correction based on a simple radiographic scattering model.

    abstract::In common radiography, image contrast is often limited due mainly to scattered x-rays and noise, decreasing the quantitative usefulness of x-ray images. Several scatter reduction methods based on software correction schemes have been extensively investigated in an attempt to overcome these difficulties, most of which ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1893-1

    authors: Kim K,Kang S,Kim W,Park C,Lee D,Cho H,Kang W,Park S,Kim G,Lim H,Lee H,Park J,Jeon D,Lim Y,Woo T,Oh J

    更新日期:2019-02-01 00:00:00

  • Theoretical evaluation of a simple cooling pad for inducing hypothermia in the spinal cord following traumatic injury.

    abstract::The Pennes bioheat equation and finite element method (FEM) are used to solve for the temperature distributions in the spinal cord and cerebrospinal fluid (CSF) during 30 min of cooling for spinal cord injury (SCI) patients. The average CSF and spinal cord temperatures are reduced by 3.48 and 2.72 degrees C, respectiv...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0543-z

    authors: Smith KD,Zhu L

    更新日期:2010-02-01 00:00:00

  • CT-3D rotational angiography automatic registration: a sensitivity analysis.

    abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02351041

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Causin F,Colombo F

    更新日期:2005-09-01 00:00:00

  • Clinical applications of musculoskeletal modelling for the shoulder and upper limb.

    abstract::Musculoskeletal models have been developed to estimate internal loading on the human skeleton, which cannot directly be measured in vivo, from external measurements like kinematics and external forces. Such models of the shoulder and upper extremity have been used for a variety of purposes, ranging from understanding ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-013-1099-5

    authors: Bolsterlee B,Veeger DH,Chadwick EK

    更新日期:2013-09-01 00:00:00

  • CSF dynamic analysis of a predictive pulsatility-based infusion test for normal pressure hydrocephalus.

    abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1110-1

    authors: Qvarlander S,Malm J,Eklund A

    更新日期:2014-01-01 00:00:00

  • Duchenne muscular dystrophy quantification: a multivariate analysis of surface EMG.

    abstract::The paper describes a method of quantifying Duchenne muscular dystrophy which is examiner independent and uses surface electromyographic signals (EMG). A standardised protocol is proposed. Spectral parameters are first computed from digitised EMG, then a polynomial model is deduced from the evolution of each parameter...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446966

    authors: Priez A,Duchene J,Goubel F

    更新日期:1992-05-01 00:00:00

  • Sensitivity of hip tissues contact evaluation to the methods used for estimating the hip joint center of rotation.

    abstract::Computer-based simulations of human hip joints generally include investigating contacts happening among soft or hard tissues during hip movement. In many cases, hip movement is approximated as rotation about an estimated hip center. In this paper, we investigate the effect of different methods used for estimating hip ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0873-0

    authors: Arbabi E,Schmid J,Boulic R,Thalmann D,Magnenat-Thalmann N

    更新日期:2012-06-01 00:00:00

  • Modeling the pharyngeal anatomical effects on breathing resistance and aerodynamically generated sound.

    abstract::The objective of this study was to systematically assess the effects of pharyngeal anatomical details on breathing resistance and acoustic characteristics by means of computational modeling. A physiologically realistic nose-throat airway was reconstructed from medical images. Individual airway anatomy such as the uvul...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1160-z

    authors: Xi J,Si X,Kim J,Su G,Dong H

    更新日期:2014-07-01 00:00:00

  • 3D shape analysis to reduce false positives for lung nodule detection systems.

    abstract::Using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), we developed a methodology for classifying lung nodules. The proposed methodology uses image processing and pattern recognition techniques. To classify volumes of interest into nodules and non-nodules, we used shape mea...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1582-x

    authors: Filho AOC,Silva AC,de Paiva AC,Nunes RA,Gattass M

    更新日期:2017-08-01 00:00:00

  • Image-based state-of-the-art techniques for the identification and classification of brain diseases: a review.

    abstract::Detection and classification methods have a vital and important role in identifying brain diseases. Timely detection and classification of brain diseases enable an accurate identification and effective management of brain impairment. Brain disorders are commonly most spreadable diseases and the diagnosing process is t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-020-02256-z

    authors: Haq EU,Huang J,Kang L,Haq HU,Zhan T

    更新日期:2020-11-01 00:00:00

  • Young and advanced tumor-some 2D electrodynamic distinctions: melanoma and satellite during a vascular occlusion test: feasibility study.

    abstract::Conventional methods of electrobioimpedance imaging are not suited for adequate visualization of the skin electrical impedance landscape (SEL) because they do not provide high spatial resolution at large enough area of view. The skin electrodynamics introscopy (SEI) enabled dynamic spectral imaging of the SEL at 32 × ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1668-0

    authors: Babich Y,Nuzhdina M,Syniuta S

    更新日期:2018-02-01 00:00:00

  • Intelligent prediction of kinetic parameters during cutting manoeuvres.

    abstract::Due to its capabilities in analysing injury risk, the ability to analyse an athlete's ground reaction force and joint moments is of high interest in sports biomechanics. However, using force plates for the kinetic measurements influences the athlete's performance. Therefore, this study aims to use a feed-forward neura...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02000-2

    authors: Mundt M,David S,Koeppe A,Bamer F,Markert B,Potthast W

    更新日期:2019-08-01 00:00:00

  • Gastric emptying of solids measured by means of magnetised iron oxide powder.

    abstract::The aim of this study was to develop a radiation-free method to measure gastric emptying. Such a method would be useful e.g. for patients who need repeated measurements and in pregnancy. Ferrimagnetic particles (gamma-Fe2O3), ingested within a solid test meal (pancakes), were magnetised by an applied magnetic field. A...

    journal_title:Medical & biological engineering & computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02522849

    authors: Forsman M

    更新日期:1998-01-01 00:00:00

  • Analysis of implantable cardioverter defibrillator signals for non conventional cardiac electrical activity characterization.

    abstract::Implantable cardioverter defibrillators (ICDs) can store intracardiac electrograms (EGMs) in sinus rhythm (SR), at the onset of spontaneous ventricular tachyarrhythmias (VT) or during their course. This allows the investigation of unknown features of the heart electrical activity associated with different cardiac rhyt...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0014-0

    authors: Casaleggio A,Rossi P,Faini A,Guidotto T,Malavasi V,Musso G,Sartori G

    更新日期:2006-03-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • Pattern recognition approach to the detection of single-trial event-related functional magnetic resonance images.

    abstract::Functional magnetic resonance imaging (FMRI) is an imaging technique for determining which regions of the brain are activated in response to a stimulus or event. Early FMRI experiment paradigms were based upon those used in positron emission tomography (PET), i.e. employing a block design consisting of extended period...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347541

    authors: Burke D,Murphy K,Garavan H,Reilly R

    更新日期:2004-09-01 00:00:00

  • Recording fetal breathing movements with a passive transducer based on an inductive principle.

    abstract::A new transducer has been developed, based on an inductive principle, for recording fetal movements and sounds. The compliance of this transducer, the INductive PHOno-sensor (INPHO), can be matched to that of the maternal abdomen to provide an optimal transfer of displacement between maternal abdomen and transducer. I...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02441655

    authors: Goovaerts HG,van Geijn HP,Rompelman O,Mantel R,Swartjes JM

    更新日期:1991-07-01 00:00:00