Abstract:
:A simple objective screening method for diagnosis of the atrial septal defect (ASD) is needed. Acoustic signals were collected from 61 children with ASD and 60 with a physiological murmur. The second heart sound (S2) and the spectrum of systolic murmur were analysed. A statistical model was designed using stepwise logistic regression analysis. Significant variables distinguishing pathological form normal findings were the interval between the first heart sound and the beginning of systolic murmur or the respiratory variation of S2, and the frequency of the murmur at its maximum intensity. The area under the ROC curve was 0.922; indicating very good fit of the model and the confidence interval was 0.872-0.971. The sensitivity of the model was 91% and the specificity 73%. The analysis of acoustic findings from the heart is a valuable tool in diagnosing ASD. The next step will be automating this process.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
El-Segaier M,Pesonen E,Lukkarinen S,Peters K,Ingemansson J,Sörnmo L,Sepponen Rdoi
10.1007/s11517-006-0094-5subject
Has Abstractpub_date
2006-09-01 00:00:00pages
739-45issue
9eissn
0140-0118issn
1741-0444journal_volume
44pub_type
杂志文章abstract::Tissue surface temperature distribution on the treatment site can serve as an indicator for the effectiveness of a photothermal therapy. In this study, both infrared thermography and theoretical simulation were used to determine the surface temperature distribution during laser irradiation of both gel phantom and anim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0251-5
更新日期:2008-02-01 00:00:00
abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1226-y
更新日期:2015-12-01 00:00:00
abstract::To describe upper airway obstruction in patients with sleep apnea syndrome, the steady state solutions of a simple model of local pharyngeal obstruction were studied. Importantly, the present model embodies a series of two individualised elements, each having its own compliance, which enables the consideration, from a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510972
更新日期:1997-11-01 00:00:00
abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344729
更新日期:2005-07-01 00:00:00
abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344698
更新日期:2000-01-01 00:00:00
abstract::Hepatic echinococcosis (HE) is a life-threatening liver disease caused by parasites that requires a precise diagnosis and proper treatments. To assess HE lesions accurately, we propose a novel automatic HE lesion segmentation and classification network that contains lesion region positioning (LRP) and lesion region se...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02126-8
更新日期:2020-03-01 00:00:00
abstract::This article compares the determination of body fat-free-mass (FFM) by impedance, using either hand-to-foot resistance (R₁₃) or foot-to-foot one (R₃₄) from comparison with dual X-ray absorptiometry (DXA) measurements in a normal population. The first goal was to see if the foot-to-foot resistance used in body fat anal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0827-y
更新日期:2011-11-01 00:00:00
abstract::An original numerical method is developed to compute the 3D electric potential generated by a dot-contact cuff electrode implanted around an axisymmetrical, inhomogeneous, anisotropic nerve. The technique is based on a 2D finite-element approach coupled with a semi-analytical Fourier spectral decomposition to approxim...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513375
更新日期:1999-11-01 00:00:00
abstract::Obstructive sleep apnea syndrome (OSAS) is a major public health problem. The golden reference for diagnosing OSAS is the sleep-laboratory based polysomnography (PSG). However, screening of population for OSAS may be practical and cost efficient only through ambulatory home recordings. In this work we aimed to design,...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0418-8
更新日期:2009-01-01 00:00:00
abstract::In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different seque...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1302-y
更新日期:2015-10-01 00:00:00
abstract::The object of this study is to compare the performance of two new bilinear time-frequency representation techniques with the spectrogram to characterise the behaviour of heart murmurs produced by bioprosthetic heart valves implanted in the mitral or aortic position. The murmurs are those of mitral stenosis, mitral reg...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02525526
更新日期:1997-09-01 00:00:00
abstract::The advent of multifunctional nanoparticle has enabled numerous innovative strategies in diagnostics, imaging, and cancer therapy. Despite the intense research efforts in developing new nanoparticles and surface bonding ligands, one major obstacle in achieving highly effective treatment, including minimizing detriment...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1818-z
更新日期:2018-11-01 00:00:00
abstract::The study focuses on the problems of dimensionality reduction by means of principal component analysis (PCA) in the context of single-trial EEG data classification (i.e. discriminating between imagined left- and right-hand movement). The principal components with the highest variance, however, do not necessarily carry...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522476
更新日期:1998-05-01 00:00:00
abstract::A hydrodynamic model for the part of the human arterial network below the renal arteries has been constructed using specially fabricated distensible tubes and a pulsatile pump to simulate an aortoiliac bypass. The experiments and the computer model indicated that no 'steal' occurred due to the insertion of the bypass ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441802
更新日期:1993-11-01 00:00:00
abstract::A computer controlled mechanical lung model has been developed for testing lung function equipment, validation of computer programs and simulation of impaired pulmonary mechanics. The construction, function and some applications are described. The physical model is constructed from two bellows and a pipe system repres...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523009
更新日期:1995-11-01 00:00:00
abstract::Visual inspection of foetal heart rate (FHR) sequences is an important means of foetal well-being evaluation. The application of fractal features for classifying physiologically relevant FHR sequence patterns is reported. The use of fractal features is motivated by the difficulties exhibited by traditional classificat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510743
更新日期:1998-03-01 00:00:00
abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02101-y
更新日期:2020-05-01 00:00:00
abstract::Biomechanical models used to estimate joint loads often predict that antagonistic muscles are inactive or underestimate their contributions [3, 5]. This can result in systematic underestimation of muscle force predictions and joint contact forces. To test the feasibility of employing an empirical co-activation ratio t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1081-2
更新日期:2014-03-01 00:00:00
abstract::It is proposed that myo-electric signals can be used to augment conventional speech-recognition systems to improve their performance under acoustically noisy conditions (e.g. in an aircraft cockpit). A preliminary study is performed to ascertain the presence of speech information within myo-electric signals from facia...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345373
更新日期:2001-07-01 00:00:00
abstract::Therapeutic hypothermia is a treatment method to reduce brain injuries after stroke, especially for cerebral ischemia. This study investigates in the temperature distribution of the head within selective brain cooling (SBC). Anatomically accurate geometries based on CT images of head and neck regions are used to devel...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01962-7
更新日期:2019-06-01 00:00:00
abstract::Two ways of rate control for diaphragm pacing are proposed. One is rate control using only the patients' body temperature (method I). The other is rate control by both the patients' heart rate and body temperature (method II). To test the effectiveness of these methods, a diaphragm pacemaker which can be controlled by...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446125
更新日期:1992-03-01 00:00:00
abstract::The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510526
更新日期:1995-05-01 00:00:00
abstract::A continuous cardiac output monitoring system has been developed in the laboratory to allow the real-time measurement of the cardiac output. This form of continuous cardiac output measurement allows the doctor to view the beat-to-beat cardiac output and can be employed to measure artery constrictions as well. The sens...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345272
更新日期:2001-01-01 00:00:00
abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-007-0264-0
更新日期:2007-12-01 00:00:00
abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1110-1
更新日期:2014-01-01 00:00:00
abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348090
更新日期:2003-07-01 00:00:00
abstract::Conventional methods of electrobioimpedance imaging are not suited for adequate visualization of the skin electrical impedance landscape (SEL) because they do not provide high spatial resolution at large enough area of view. The skin electrodynamics introscopy (SEI) enabled dynamic spectral imaging of the SEL at 32 × ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1668-0
更新日期:2018-02-01 00:00:00
abstract::Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel struc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351041
更新日期:2005-09-01 00:00:00
abstract::The three-dimensional changes in the cytoskeleton and in cell proliferation of bovine pulmonary artery endothelial cells when exposed to sustained hydrostatic pressure were investigated in vitro using laser scanning confocal microscopy. Subconfluent endothelial cells on rigid substrates were exposed to 1.5, 5 and 10 c...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523225
更新日期:1998-07-01 00:00:00
abstract::The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0373-4
更新日期:2008-09-01 00:00:00