Abstract:
:The aim of this study was to evaluate feasibility and reproducibility of quantitative assessment of colonic morphology on CT colonography (CTC). CTC datasets from 60 patients with optimal colonic distension were assessed using prototype software. Metrics potentially associated with poor endoscopic performance were calculated for the total colon and each segment including: length, volume, tortuosity (number of high curvature points <90°), and compactness (volume of box containing centerline divided by centerline length). Sigmoid apex height relative to the lumbosacral junction was also measured. Datasets were quantified twice each, and intra-reader reliability was evaluated using concordance correlation coefficient and Bland-Altman plot. Complete quantitative datasets including the five proposed metrics were generated from 58 of 60 (97 %) CTC examinations. The sigmoid and transverse segments were the longest (55.9 and 51.4 cm), had the largest volumes (0.410 and 0.609 L), and were the most tortuous (3.39 and 2.75 high curvature points) and least compact (3347 and 3595 mm2), noting high inter-patient variability for all metrics. Mean height of the sigmoid apex was 6.7 cm, also with high inter-patient variability (SD 6.8 cm). Intra-reader reliability was high for total and segmental lengths and sigmoid apex height (CCC = 0.9991) with excellent repeatability coefficient (CR = 3.0-3.3). There was low percent variance of metrics dependent upon length (median 5 %). Detailed automated quantitative assessment of colonic morphology on routine CTC datasets is feasible and reproducible, requiring minimal reader interaction.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Weber CN,Lev-Toaff AS,Levine MS,Sudarsky S,Guendel L,Geiger B,Zafar HMdoi
10.1007/s11517-016-1529-2subject
Has Abstractpub_date
2017-03-01 00:00:00pages
507-515issue
3eissn
0140-0118issn
1741-0444pii
10.1007/s11517-016-1529-2journal_volume
55pub_type
杂志文章abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02347054
更新日期:2000-05-01 00:00:00
abstract::Axial and transverse components of liquid velocity are measured by laser Doppler anemometer in a perspex tube that has been deformed at one point to resemble the shape of the throat of a partially collapsed flexible tube, conveying fluid while being compressed externally. The Reynolds number is 5900. The flow down-str...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345363
更新日期:2001-07-01 00:00:00
abstract::This study describes a new method for analyzing microcirculatory videos. It introduces algorithms for quantitative assessment of vessel length, diameter, the functional microcirculatory density distribution and red blood-cell (RBC) velocity in individual vessels as well as its distribution. The technique was validated...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0349-4
更新日期:2008-07-01 00:00:00
abstract::Partial coherence estimate between two signals removing the contribution of a periodic, deterministic one is proposed for measuring the coherence between two ongoing eletroencephalografic (EEG) activities collected at distinct cortical regions under sensory stimulation. The estimator expression was derived and shown t...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0191-0
更新日期:2007-07-01 00:00:00
abstract::Quantitative sensory testing (QST) can provide useful information about the underlying mechanisms involved in chronic pain. However, currently available devices typically employed suffer from operator-dependent effects, or are too cumbersome for routine clinical care. This paper presents the design and initial validat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1033-x
更新日期:2013-06-01 00:00:00
abstract::During dialysis the ion concentrations in many body fluids change significantly. The influence of these changes on the accuracy of volume measurements with bioimpedance spectroscopy is investigated by the following procedure: Plasma ion concentrations and impedance spectra (5-500 kHz) are measured during six standard ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02534137
更新日期:1997-03-01 00:00:00
abstract::Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1703-1
更新日期:2018-03-01 00:00:00
abstract::Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02088-6
更新日期:2020-02-01 00:00:00
abstract::During scoliosis instrumentation surgery, it is difficult for surgeons fully to track vertebral motion in 3D, because only the posterior elements of the spine are exposed. Different intra-operative modelling approaches are evaluated using a registration technique that matches intra-operative measurements with a 3D pre...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513328
更新日期:1999-07-01 00:00:00
abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446086
更新日期:1991-11-01 00:00:00
abstract::The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02523842
更新日期:1996-11-01 00:00:00
abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0497-1
更新日期:2009-08-01 00:00:00
abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0139-9
更新日期:2007-01-01 00:00:00
abstract::The development of an active implantable device for measuring electrocardiogram (ECG) is presented. The study is a part of a project which aims at developing implantable ECG instrumentation with wireless data and power transfer ( http://www.ele.tut.fi/tule ). The developed implant presented here has all the measuremen...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-007-0264-0
更新日期:2007-12-01 00:00:00
abstract::Nowadays, acoustic emission (AE) has its applications in various areas, including mechanical, civil, underwater acoustics, and biomedical engineering. It is a non-destructive evaluation (NDE) and a non-intrusive method to detect active damage mechanisms such as crack growth, delamination, and processes such as frictio...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-020-02202-z
更新日期:2020-08-01 00:00:00
abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348430
更新日期:2003-05-01 00:00:00
abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446881
更新日期:1993-01-01 00:00:00
abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02447101
更新日期:1991-03-01 00:00:00
abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0886-8
更新日期:2012-05-01 00:00:00
abstract::Detailed finite element (FE) models are used as promising tools to investigate traumatic brain injuries, although their accuracy is strongly dependent on the characterization of the mechanical behaviors of the different anatomic structures in the brain. In some cases, when the FE models require finer spatial resolutio...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1891-3
更新日期:2019-03-01 00:00:00
abstract::The software system GASepo has been developed as a tool to visualise and analyse doping (searching for performance-enhancing drugs in sports) with recombinant erythropoietin (rEpo). Digital images derived from the separation of Epo isoforms in gels by iso-electric focusing followed by double blotting and chemiluminesc...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345819
更新日期:2005-05-01 00:00:00
abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01995-y
更新日期:2019-08-01 00:00:00
abstract::Precise segmentation of stroke lesions from brain magnetic resonance (MR) images poses a challenging task in automated diagnosis. In this paper, we proposed a new method called watershed-based lesion segmentation algorithm (WLSA), which is a novel intensity-based segmentation technique used to delineate infarct lesion...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-017-1726-7
更新日期:2018-05-01 00:00:00
abstract::Infants born at 35-37 weeks' gestational age (GA) are at higher risk for a range of pathological conditions and poorer neurodevelopmental outcomes. However, mechanisms responsible are not fully understood. The purpose of this paper is to use traditional and novel techniques to assess newborn autonomic development as a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1866-4
更新日期:2019-01-01 00:00:00
abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0055-z
更新日期:2006-06-01 00:00:00
abstract::Taking advantage of motion sensing technology, a quantitative assessment method for lower limbs motor function of cerebral palsy (CP) based on the gross motor function measurement (GMFM)-24 scale was explored in this study. According to the motion analysis on GMFM-24 scale, we translated the assessment problem of GMFM...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02076-w
更新日期:2020-01-01 00:00:00
abstract::The complexity of the monitored data available in modern intensive care units suggests that they may be best processed, for presentation to medical staff, by expert system techniques. However, standard expert system shells are ill-fitted to either the basic sequential monitoring tasks of data acquisition and storage, ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02525536
更新日期:1997-09-01 00:00:00
abstract::A comparison of auditory and visual perception of scatterplots showed similar correlation estimation performance in both modalities. The present study replicated this experiment using electrotactile (electrocutaneous) presentation of scatterplots on the fingertips and abdomen, as well as visual presentation. The corre...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345967
更新日期:2005-03-01 00:00:00
abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02282-x
更新日期:2020-12-01 00:00:00
abstract::A new method of quantifying dermal perfusion on a regional basis using a dynamic thermographic technique is investigated. The technique is based on the relationship between dermal perfusion and the rate of skin surface reheating following the application of a transient cold challenge predicted by a theoretical model. ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441468
更新日期:1989-09-01 00:00:00