Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes.

Abstract:

:The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.

journal_name

Med Biol Eng Comput

authors

Linder P,Trzewik J,Rüffer M,Artmann GM,Digel I,Kurz R,Rothermel A,Robitzki A,Temiz Artmann A

doi

10.1007/s11517-009-0552-y

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

59-65

issue

1

eissn

0140-0118

issn

1741-0444

journal_volume

48

pub_type

杂志文章
  • A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

    abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0348-5

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-07-01 00:00:00

  • Effect of flow disturbances remaining at the beginning of diastole on intraventricular diastolic flow and colour M-mode Doppler echocardiograms.

    abstract::A computational model of the fluid dynamics of intraventricular flow was used to investigate the importance of the effects of flow disturbances existing within the left ventricle (LV) at the onset of diastole on a diastolic flow field. The simulation started with a quiescent flow state; it continued for a number of ca...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02350992

    authors: Nakamura M,Wada S,Mikami T,Kitabatake A,Karino T,Yamaguchi T

    更新日期:2004-07-01 00:00:00

  • Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences.

    abstract::A model which assesses the closed-loop interaction between heart period (HP) and arterial pressure (AP) variabilities and the influence of respiration on both is applied to evaluate the sources of low frequency (LF approximately 0.1 Hz) and high frequency (HF, respiratory rate approximately 0.25 Hz) in conscious dogs ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518911

    authors: Baselli G,Cerutti S,Badilini F,Biancardi L,Porta A,Pagani M,Lombardi F,Rimoldi O,Furlan R,Malliani A

    更新日期:1994-03-01 00:00:00

  • Assessment of heart rate variability by application of central tendency measure.

    abstract::The heart rate variability (HRV) is an indicator of the subject homeostasis alterations. For a healthy individual, the HRV shows a nonlinear behavior, thus requiring a nonlinear approach to provide additional information about HRV dynamics. In this work, the nonlinear techniques, central tendency measure (CTM) and sec...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1390-8

    authors: dos Santos L,Barroso JJ,Macau EE,de Godoy MF

    更新日期:2015-11-01 00:00:00

  • A comparison approach toward finding the best feature and classifier in cue-based BCI.

    abstract::In this paper, a comparative evaluation of state-of-the art feature extraction and classification methods is presented for five subjects in order to increase the performance of a cue-based Brain-Computer interface (BCI) system for imagery tasks (left and right hand movements). To select an informative feature with a r...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-007-0169-y

    authors: Boostani R,Graimann B,Moradi MH,Pfurtscheller G

    更新日期:2007-04-01 00:00:00

  • CSF dynamic analysis of a predictive pulsatility-based infusion test for normal pressure hydrocephalus.

    abstract::Disturbed cerebrospinal fluid (CSF) dynamics are part of the pathophysiology of normal pressure hydrocephalus (NPH) and can be modified and treated with shunt surgery. This study investigated the contribution of established CSF dynamic parameters to AMP(mean), a prognostic variable defined as mean amplitude of cardiac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1110-1

    authors: Qvarlander S,Malm J,Eklund A

    更新日期:2014-01-01 00:00:00

  • Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo.

    abstract::We have successfully developed a multiscale acoustic-resolution photoacoustic tomography system in a single imaging platform. By switching between ultrasound transducers (center frequencies 5 and 40 MHz) and optical condensers, we have photoacoustically imaged microvasculatures of small animals in vivo at different sc...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-014-1182-6

    authors: Jeon M,Kim J,Kim C

    更新日期:2016-03-01 00:00:00

  • Computer-controlled positive displacement pump for physiological flow simulation.

    abstract::A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the product...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446086

    authors: Holdsworth DW,Rickey DW,Drangova M,Miller DJ,Fenster A

    更新日期:1991-11-01 00:00:00

  • Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

    abstract::Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0653-7

    authors: Yang Z,Wickwire AC,Debski RE

    更新日期:2010-11-01 00:00:00

  • Assessment of a procedure for detecting minute levels of tooth erosion.

    abstract::Over a period of some years, the components of a system for discerning erosion on children's teeth have been progressively developed, for use in an extensive project seeking correlations between erosion and various perceived risk factors. The aim was the detection of minute levels of erosion, based on mappings of the ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02348090

    authors: Mitchell HL,Chadwick RG,Ward S,Manton SL

    更新日期:2003-07-01 00:00:00

  • Progressive changes of elastic moduli of arterial wall and atherosclerotic plaque components during plaque development in human coronary arteries.

    abstract::Stiffness of the arterial wall and atherosclerotic plaque components is a determinant of the stress field within plaques, which has been suggested to be an indicator of plaque vulnerability. The diversity and inhomogeneous structure of atherosclerotic lesions complicate the characterization of plaque components. In th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1910-4

    authors: Rezvani-Sharif A,Tafazzoli-Shadpour M,Avolio A

    更新日期:2019-03-01 00:00:00

  • Bivariate nonlinear prediction to quantify the strength of complex dynamical interactions in short-term cardiovascular variability.

    abstract::A nonlinear prediction method for investigating the dynamic interdependence between short length time series is presented. The method is a generalization to bivariate prediction of the univariate approach based on nearest neighbor local linear approximation. Given the input and output series x and y, the relationship ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0043-3

    authors: Faes L,Nollo G

    更新日期:2006-05-01 00:00:00

  • A multi-electrode array and inversion technique for retrieving six conductivities from heart potential measurements.

    abstract::A method for accurately finding cardiac bidomain conductivity parameters is a crucial part of efforts to study and understand the electrical functioning of the heart. The bidomain model considers current flowing along (longitudinal) and across (transverse) sheets of cardiac fibres, as well as between these sheets (nor...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1101-2

    authors: Johnston BM,Johnston PR

    更新日期:2013-12-01 00:00:00

  • Evaluation of divided attention using different stimulation models in event-related potentials.

    abstract::Divided attention is defined as focusing on different tasks at once, and this is described as one of the biggest problems of today's society. Default examinations for understanding attention are questionnaires or physiological signals, like evoked potentials and electroencephalography. Physiological records were obtai...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02013-x

    authors: Batbat T,Güven A,Dolu N

    更新日期:2019-09-01 00:00:00

  • Viscoelastic response of human hair cortex.

    abstract::The present study describes a new methodological approach which allows the separate analysis and quantitative determination of the viscous and elastic components of human hair using a computerised experimental system. In a first series of experiments subsequent to the estimation of the cross-sectional surface area of ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446198

    authors: Nikiforidis G,Balas C,Tsambaos D

    更新日期:1992-01-01 00:00:00

  • Matching between theoretical and experimental data for ELF ion transport effects.

    abstract::In recent years, several studies have been focused on the problem of nonthermal interaction between extremely low-frequency (ELF) electromagnetic fields and cell environment at membrane level. In the paper, to analyse the dynamic effects of weak static and harmonic fields on charged particles, some new considerations ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446654

    authors: D'Inzeo G,Galli A,Palombo A

    更新日期:1993-07-01 00:00:00

  • Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure.

    abstract::This paper presents a novel hybrid medical stent device. This hybrid stent device formed by fractal mesh structures provides a flow-diverting effect and stent-assisted coil embolization. Flow-diverter stents decrease blood flow into an aneurysm to prevent its rupture. In general, the mesh size of a flow-diverter stent...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1374-8

    authors: Kojima M,Irie K,Masunaga K,Sakai Y,Nakajima M,Takeuchi M,Fukuda T,Arai F,Negoro M

    更新日期:2016-05-01 00:00:00

  • Modelling and multi-parametric control for delivery of anaesthetic agents.

    abstract::This article presents model predictive controllers (MPCs) and multi-parametric model-based controllers for delivery of anaesthetic agents. The MPC can take into account constraints on drug delivery rates and state of the patient but requires solving an optimization problem at regular time intervals. The multi-parametr...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0604-3

    authors: Dua P,Dua V,Pistikopoulos EN

    更新日期:2010-06-01 00:00:00

  • Improvement of spike train decoder under spike detection and classification errors using support vector machine.

    abstract::The successful decoding of kinematic variables from spike trains of motor cortical neurons is essential for cortical neural prosthesis. Spike trains from each single unit must be extracted from extracellular neural signals and, thus, spike detection and sorting procedure is indispensable but the detection and sorting ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-005-0009-x

    authors: Kim KH,Kim SS,Kim SJ

    更新日期:2006-03-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Industrial wideband noise reduction for hearing aids using a headset with adaptive-feedback active noise cancellation.

    abstract::High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02430951

    authors: Lin JH,Li PC,Tang ST,Liu PT,Young ST

    更新日期:2005-11-01 00:00:00

  • Automatic P-wave analysis of patients prone to atrial fibrillation.

    abstract::A method is presented for automatic analysis of the P-wave, based on lead II of a 12-lead standard ECG, in resting conditions during a routine examination for the detection of patients prone to atrial fibrillation (AF), one of the most prevalent arrhythmias. First, the P-wave was delineated, and this was achieved in t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347697

    authors: Clavier L,Boucher JM,Lepage R,Blanc JJ,Cornily JC

    更新日期:2002-01-01 00:00:00

  • Refixation stability in shoulder hemiarthroplasty in case of four-part proximal humeral fracture.

    abstract::Primary stability of refixated fractures in case of shoulder hemiarthroplasty is a prerequisite to restore physiological glenohumeral joint function. Clinical observations often show a secondary dislocation and subsequent resorption of the bony anchor points like the greater and lesser tuberosity at the rotator cuff t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0483-7

    authors: Baumgartner D,Lorenzetti SR,Mathys R,Gasser B,Stüssi E

    更新日期:2009-05-01 00:00:00

  • A fully automated hybrid human sperm detection and classification system based on mobile-net and the performance comparison with conventional methods.

    abstract::Sperm morphology, as an indicator of fertility, is a critical tool in semen analysis. In this study, a smartphone-based hybrid system that fully automates the sperm morphological analysis is introduced with the aim of eliminating unwanted human factors. Proposed hybrid system consists of two progressive steps: automat...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02101-y

    authors: Ilhan HO,Sigirci IO,Serbes G,Aydin N

    更新日期:2020-05-01 00:00:00

  • Estimation of dynamic metabolic activity in micro-tissue cultures from sensor recordings with an FEM model.

    abstract::We estimated the dynamic cell metabolic activity and the distribution of the pH value and oxygen concentration in tissue samples cultured in vitro by using real-time sensor records and a numerical simulation of the underlying reaction-diffusion processes. As an experimental tissue model, we used chicken spleen slices....

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-015-1367-7

    authors: Pfister C,Forstmeier C,Biedermann J,Schermuly J,Demmel F,Wolf P,Kaspers B,Brischwein M

    更新日期:2016-05-01 00:00:00

  • A convolutional neural network-based learning approach to acute lymphoblastic leukaemia detection with automated feature extraction.

    abstract::Leukaemia is a type of blood cancer which mainly occurs when bone marrow produces excess white blood cells in our body. This disease not only affects adult but also is a common cancer type among children. Treatment of leukaemia depends on its type and how far the disease has spread in the body. Leukaemia is classified...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02282-x

    authors: Anwar S,Alam A

    更新日期:2020-12-01 00:00:00

  • Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS).

    abstract::A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capac...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02518872

    authors: Ishikawa N,Suda S,Sasaki T,Yamanishi T,Hosaka H,Yasuda K,Ito H

    更新日期:1998-11-01 00:00:00

  • Evaluation of feature extraction techniques and classifiers for finger movement recognition using surface electromyography signal.

    abstract::Electromyography (EMG) in a bio-driven system is used as a control signal, for driving a hand prosthesis or other wearable assistive devices. Processing to get informative drive signals involves three main modules: preprocessing, dimensionality reduction, and classification. This paper proposes a system for classifyin...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-1857-5

    authors: Phukpattaranont P,Thongpanja S,Anam K,Al-Jumaily A,Limsakul C

    更新日期:2018-12-01 00:00:00

  • Adaptive processing bandwidth adjustment for laser Doppler flowmetry.

    abstract::A novel laser Doppler flowmetry scheme is reported that adjusts the processing bandwidth adaptively to optimise the estimation of flow. To obtain an adequate processing bandwidth, the Doppler spectra is first fitted to the Lorentzian function, and the bandwidth at half the maximum of the Lorentzian function is used as...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02344700

    authors: Chen YY,Lin YH,Jan IC,Liu RS,Chou NK,Jan GJ

    更新日期:2004-05-01 00:00:00

  • Dual-sectored transurethral ultrasound for thermal treatment of stress urinary incontinence: in silico studies in 3D anatomical models.

    abstract::The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulation...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02152-6

    authors: Liu D,Adams M,Burdette EC,Diederich CJ

    更新日期:2020-06-01 00:00:00