Abstract:
:Photoplethysmography imaging (PPGI) for non-contact monitoring of preterm infants in the neonatal intensive care unit (NICU) is a promising technology, as it could reduce medical adhesive-related skin injuries and associated complications. For practical implementations of PPGI, a region of interest has to be detected automatically in real time. As the neonates' body proportions differ significantly from adults, existing approaches may not be used in a straightforward way, and color-based skin detection requires RGB data, thus prohibiting the use of less-intrusive near-infrared (NIR) acquisition. In this paper, we present a deep learning-based method for segmentation of neonatal video data. We augmented an existing encoder-decoder semantic segmentation method with a modified version of the ResNet-50 encoder. This reduced the computational time by a factor of 7.5, so that 30 frames per second can be processed at 960 × 576 pixels. The method was developed and optimized on publicly available databases with segmentation data from adults. For evaluation, a comprehensive dataset consisting of RGB and NIR video recordings from 29 neonates with various skin tones recorded in two NICUs in Germany and India was used. From all recordings, 643 frames were manually segmented. After pre-training the model on the public adult data, parts of the neonatal data were used for additional learning and left-out neonates are used for cross-validated evaluation. On the RGB data, the head is segmented well (82% intersection over union, 88% accuracy), and performance is comparable with those achieved on large, public, non-neonatal datasets. On the other hand, performance on the NIR data was inferior. By employing data augmentation to generate additional virtual NIR data for training, results could be improved and the head could be segmented with 62% intersection over union and 65% accuracy. The method is in theory capable of performing segmentation in real time and thus it may provide a useful tool for future PPGI applications. Graphical Abstract This work presents the development of a customized, real-time capable Deep Learning architecture for segmenting of neonatal videos recorded in the intensive care unit. In addition to hand-annotated data, transfer learning is exploited to improve performance.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Antink CH,Ferreira JCM,Paul M,Lyra S,Heimann K,Karthik S,Joseph J,Jayaraman K,Orlikowsky T,Sivaprakasam M,Leonhardt Sdoi
10.1007/s11517-020-02251-4subject
Has Abstractpub_date
2020-12-01 00:00:00pages
3049-3061issue
12eissn
0140-0118issn
1741-0444pii
10.1007/s11517-020-02251-4journal_volume
58pub_type
杂志文章abstract::A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory settin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0464-x
更新日期:2009-05-01 00:00:00
abstract::This study examined the electroencephalogram functional connectivity (coherence) and effective connectivity (flow of information) of selected brain regions during three different attentive states: awake, meditation and drowsiness. For the estimation of functional connectivity (coherence), Welch and minimum variance di...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1272-0
更新日期:2015-07-01 00:00:00
abstract::The purpose of this study is to investigate the feasibility and performance of a stationary, non-focused dual-sectored tubular transurethral ultrasound applicator for thermal exposure of tissue regions adjacent to the urethra for treatment of stress urinary incontinence (SUI) through acoustic and biothermal simulation...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-020-02152-6
更新日期:2020-06-01 00:00:00
abstract::The vagus nerves convey both afferent and efferent information about autonomic activity related to cardiovascular functions. Those functions have been shown to change due to epileptic seizures, which suggests that ictal events might be detected via the vagus electroneurogram (VENG). In this study, we characterize the ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0782-7
更新日期:2011-09-01 00:00:00
abstract::Instrumentation to measure accurately the stresses at the interface of a residual limb and prosthetic socket has a strong potential for use in prosthetic treatment. As a tool in the clinical setting, the device would allow a clinician to identify sites of excessive loading, information which could then be combined wit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/BF02522507
更新日期:1995-07-01 00:00:00
abstract::The objective of this study was to evaluate the effect of following combined treatment with parathyroid hormone (1-34) (PTH) and beta-tricalcium phosphate (β-TCP) on local bone formation in a rat 3-mm critical-size defect at distal femur. Twelve weeks after bilateral ovariectomy (OVX) and sham operation (sham), all an...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1402-8
更新日期:2016-09-01 00:00:00
abstract::Heart rate variability (HRV) is a well-accepted indicator for neural regulatory mechanisms in cardiovascular circulation. Its spectrum analysis provides the powerful means of observing the modulation between sympathetic and parasympathetic nervous system. The timescale of HRV is limited by discrete beat-to-beat time i...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1135-5
更新日期:2014-04-01 00:00:00
abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345957
更新日期:2005-03-01 00:00:00
abstract::The three-dimensional changes in the cytoskeleton and in cell proliferation of bovine pulmonary artery endothelial cells when exposed to sustained hydrostatic pressure were investigated in vitro using laser scanning confocal microscopy. Subconfluent endothelial cells on rigid substrates were exposed to 1.5, 5 and 10 c...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523225
更新日期:1998-07-01 00:00:00
abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522517
更新日期:1995-07-01 00:00:00
abstract::We introduce a novel method for an automatic classification of subjects to those with or without neuromuscular disorders. This method is based on multiscale entropy of recorded surface electromyograms (sEMGs) and support vector classification. The method was evaluated on a single-channel experimental sEMGs recorded fr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0629-7
更新日期:2010-08-01 00:00:00
abstract::The tortuosity of retinal blood vessels is an important diagnostic indicator for a number of retinal pathologies. We applied robust quantitative tortuosity metrics, which are well suited to automated detection and measurement, to retinal fluorescein images of normal and diseased vessels exhibiting background diabetic ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0559-4
更新日期:2010-01-01 00:00:00
abstract::OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photoce...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02510786
更新日期:1995-09-01 00:00:00
abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-1016-3
更新日期:2013-04-01 00:00:00
abstract::Mean arterial pressure (MAP) is determined in most automated oscillometric blood pressure devices, but its derivation has been little studied. In this research, different techniques were studied and compared with the auscultatory technique. Auscultatory systolic and diastolic blood pressure (SBP and DBP) were obtained...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0694-y
更新日期:2011-01-01 00:00:00
abstract::Several recent studies have quantified abnormalities in Parkinsonian gait. However, few studies have attempted to quantify the regularity of body motion during walking in patients with Parkinson's disease. The aim of the paper was to characterise body motion patterns in healthy, elderly subjects and patients with Park...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02351008
更新日期:2004-01-01 00:00:00
abstract::Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacit...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1359-7
更新日期:2016-04-01 00:00:00
abstract::Blood oxygenation level is an important measure that can be used alongside functional magnetic resonance imaging data in order to obtain closer correlates of neuronal activation. A robust estimate of this measure has thus far not been demonstrated. This is mainly due to the lack of knowledge of the underlying paramete...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0886-8
更新日期:2012-05-01 00:00:00
abstract::The aim of the study was to assess the wavelength dependence of the UV absorbance during monitoring of different compounds in the dialysate. UV absorbance was determined by using a double-beam spectrophotometer on dialysate samples taken at pre-determined times during dialysis, over a wavelength range of 180-380 nm. C...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02348430
更新日期:2003-05-01 00:00:00
abstract::Atrial fibrillation (AF) is the most common cardiac arrhythmia with episodes that may terminate spontaneously in the first stages of the disease. On the other hand, when the arrhythmia is not self-terminating, normal sinus rhythm (NSR) restoration use to be required to reduce the risk of stroke and improve cardiac out...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-008-0348-5
更新日期:2008-07-01 00:00:00
abstract::From adult data, it is known that numerous factors, such as age, state of the autonomic nervous system, diurnal rhythms or mean R-R interval mRR, influence heart rate variability (HRV). The aim of this study was the examination of the influence of gestational age, mRR, gender and time of day on fetal HRV. The analysis...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344729
更新日期:2005-07-01 00:00:00
abstract::The paper describes an investigation in which it is shown that small positive voltage pulses applied to an external conductor placed against the photocathode of a photomultiplier tube can be used to switch the photocathode completely off for the duration of the pulses. This suggests that a photomultiplier tube with a ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441486
更新日期:1989-05-01 00:00:00
abstract::Breast cancer is the most common cancer among women globally, and the number of young women diagnosed with this disease is gradually increasing over the years. Mammography is the current gold-standard technique although it is known to be less sensitive in detecting tumors in woman with dense breast tissue. Detecting a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-015-1403-7
更新日期:2016-09-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00
abstract::High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02430951
更新日期:2005-11-01 00:00:00
abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章,评审
doi:10.1007/s11517-018-1887-z
更新日期:2019-01-01 00:00:00
abstract::This study analyzes the performance of knee extension and flexion of Taekwondo and Kickboxing athletes. The power values were extracted through electromyography obtained by an isokinetic dynamometer at 60 degrees per second. These values are resulted from the square of the electromyography signal. The analysis of kick...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0608-z
更新日期:2010-06-01 00:00:00
abstract::Neural networks are trained to estimate the germination percentages of Plasmopara viticola oospores, overwintered in natural conditions in two viticultural areas in northern Italy, by using climatic (temperature and rainfall) data, as well as the previous germination measurement, as input variables. The 288 available ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344698
更新日期:2000-01-01 00:00:00
abstract::While matrix remodeling plays a key role in vascular physiology and pathology, the underlying mechanisms have remained incompletely understood. We studied the remodeling of collagen matrices by individual vascular smooth muscle cells (SMCs), clusters and monolayers. In addition, we focused on the contribution of trans...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0916-6
更新日期:2012-07-01 00:00:00
abstract::Infants born at 35-37 weeks' gestational age (GA) are at higher risk for a range of pathological conditions and poorer neurodevelopmental outcomes. However, mechanisms responsible are not fully understood. The purpose of this paper is to use traditional and novel techniques to assess newborn autonomic development as a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-018-1866-4
更新日期:2019-01-01 00:00:00