Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique.

Abstract:

:Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed to perform 3D reconstruction of the spine using not only the stereo-corresponding anatomical landmarks (seen on both frontal and sagittal X-ray films) but also some non-stereo-corresponding ones. This technique (called non-stereo-corresponding points or NSCP) has already been used for cervical dry vertebrae. In the present study, we focus on the validation of this technique for lumbar vertebrae by comparing four techniques: direct measurement, CT scan, 3D reconstruction by stereoradiography using a direct linear transformation (DLT) algorithm and the NSCP technique. The accuracy of the NSCP technique was also evaluated on different vertebral regions. The global results show mean errors of 1.1 mm and maximum of 7.8 mm with regard to direct measurements. These mean errors are close to those obtained using 3D reconstructions from CT scan using 1 mm cuts.

journal_name

Med Biol Eng Comput

authors

Mitulescu A,Semaan I,De Guise JA,Leborgne P,Adamsbaum C,Skalli W

doi

10.1007/BF02344797

keywords:

subject

Has Abstract

pub_date

2001-03-01 00:00:00

pages

152-8

issue

2

eissn

0140-0118

issn

1741-0444

journal_volume

39

pub_type

杂志文章
  • Structuring of service centres for economic and equipment efficiency.

    abstract::Increasing costs in healthcare have stimulated discussions on whether installation of competent in-house service groups for equipment management could eventually aid in reducing expenditure. In the Federal Republic of Germany, a four-year programme was initiated in 1979 with the purpose of investigating the feasibilit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02442172

    authors: Irnich W

    更新日期:1989-01-01 00:00:00

  • Estimation of the lactate threshold using an electro acoustic sensor system analysing the respiratory air.

    abstract::The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system t...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-008-0373-4

    authors: Folke M

    更新日期:2008-09-01 00:00:00

  • Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.

    abstract::In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA),...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-006-0055-z

    authors: DiPietroPaolo D,Müller HP,Nolte G,Erné SN

    更新日期:2006-06-01 00:00:00

  • Fluorescence microscopy image classification of 2D HeLa cells based on the CapsNet neural network.

    abstract::The development of computer technology now allows the quick and efficient automatic fluorescence microscopy generation of a large number of images of proteins in specific subcellular compartments using fluorescence microscopy. Digital image processing and pattern recognition technology can easily classify these images...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-018-01946-z

    authors: Zhang X,Zhao SG

    更新日期:2019-06-01 00:00:00

  • Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

    abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02511245

    authors: Zhang S,Wright G,Kingston MA,Rolfe P

    更新日期:1996-07-01 00:00:00

  • Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study.

    abstract::A computer-aided method was developed to automatically localize tumors in lung PET images of discrete bins within the breathing cycle, followed by an algorithm that registers all the information of a complete respiratory cycle into a single reference bin. Four registration/integration algorithms: Centroid Based, Inten...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0549-6

    authors: Wang J,del Valle M,Goryawala M,Franquiz JM,McGoron AJ

    更新日期:2010-01-01 00:00:00

  • Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

    abstract::An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl cas...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02513315

    authors: Goto H,Sugiura T,Harada Y,Kazui T

    更新日期:1999-05-01 00:00:00

  • Dynamics of magnetic particles in cylindrical Halbach array: implications for magnetic cell separation and drug targeting.

    abstract::Magnetic nanoparticles for therapy and diagnosis are at the leading edge of the rapidly developing field of bionanotechnology. In this study, we have theoretically studied motion of magnetic nano- as well as micro-particles in the field of cylindrical Halbach array of permanent magnets. Magnetic flux density was model...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-010-0636-8

    authors: Babinec P,Krafcík A,Babincová M,Rosenecker J

    更新日期:2010-08-01 00:00:00

  • System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

    abstract::The purpose of this study is to verify the applicability of a sixth-order model to the mechanomyogram (MMG) system of the parallel-fibered muscle, which was identified from the MMG of the pennation muscle. The median nerve was stimulated, and an MMG and torque of the abductor pollicis brevis muscle were measured. The ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-013-1107-9

    authors: Uchiyama T,Sakai H

    更新日期:2013-12-01 00:00:00

  • Cephalometric image analysis and measurement for orthognathic surgery.

    abstract::Automatic identification of landmarks in cephalometry is very important and useful for orthognathic surgery. A computerised automatic cephalometric analysis system (CACAS), based on image processing, is presented. For an original X-ray image, median filtering and histogram equalisation are used to improve image qualit...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345280

    authors: Yang J,Ling X,Lu Y,Wei M,Ding G

    更新日期:2001-05-01 00:00:00

  • A novel finite element model-based navigation system-supported workflow for breast tumor excision.

    abstract::In the case of female breast cancer, a breast-conserving excision is often desirable. This surgery is based on preoperatively gathered MRI, mammography, and sonography images. These images are recorded in multiple patient positions, e. g., 2D mammography images in standing position with a compressed breast and 3D MRI ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01977-0

    authors: Esslinger D,Rapp P,Knödler L,Preibsch H,Tarín C,Sawodny O,Brucker SY,Hahn M

    更新日期:2019-07-01 00:00:00

  • Ultrasonic characterization of ultrasound contrast agents.

    abstract::The main constituent of an ultrasound contrast agent (UCA) is gas-filled microbubbles. An average UCA contains billions per ml. These microbubbles are excellent ultrasound scatterers due to their high compressibility. In an ultrasound field they act as resonant systems, resulting in harmonic energy in the backscattere...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-009-0497-1

    authors: de Jong N,Emmer M,van Wamel A,Versluis M

    更新日期:2009-08-01 00:00:00

  • Dielectric properties of bones for the monitoring of osteoporosis.

    abstract::Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-018-1887-z

    authors: Amin B,Elahi MA,Shahzad A,Porter E,McDermott B,O'Halloran M

    更新日期:2019-01-01 00:00:00

  • Application of genetic algorithms to parameter estimation of bioprocesses.

    abstract::The paper explains the application of a genetic algorithm (GA) to the problem of estimating parameters for a kinetic model of a biologically reacting system. It is demonstrated that the GA is a powerful tool for quantifying the kinetic parameters using kinetic data. As the operation of the GA does not depend on the fo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510391

    authors: Park LJ,Park CH,Park C,Lee T

    更新日期:1997-01-01 00:00:00

  • The past, present, and prospective on UV-VIS-NIR skin photonics and spectroscopy-a wavelength guide.

    abstract::The study and applications of in vivo skin optics have been openly documented as early as the year 1954, or possibly earlier. To date, challenges in analyzing the complexities of this field remain, with wide scopes requiring more scrutiny. Recent advances in spectroscopic research and multivariate analytics allow a cl...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章,评审

    doi:10.1007/s11517-019-02077-9

    authors: Poh AH,Adikan FRM,Moghavvemi M

    更新日期:2020-06-01 00:00:00

  • 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis.

    abstract::Bone mass and microarchitecture are the main determinants of bone strength. Three-dimensional micro-computed tomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. In the presented work, the proximal part of the tibiae of hindlimb unloaded an...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02347054

    authors: Laib A,Barou O,Vico L,Lafage-Proust MH,Alexandre C,Rügsegger P

    更新日期:2000-05-01 00:00:00

  • Industrial wideband noise reduction for hearing aids using a headset with adaptive-feedback active noise cancellation.

    abstract::High-intensity noises are a health hazard for industrial workers, and hearing protection is necessary to prevent hearing loss. Passive methods, such as ear muffs, are ineffective against low-frequency noise. Moreover, many hearing-impaired workers must wear hearing aids to enable communication at their workplace, and ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02430951

    authors: Lin JH,Li PC,Tang ST,Liu PT,Young ST

    更新日期:2005-11-01 00:00:00

  • Effect of radiographic landmark identification errors on the accuracy of three-dimensional reconstruction of the human spine.

    abstract::In three-dimensional reconstruction of the human spine obtained from stereo-radiographic set-ups (two radiographs or more), it is extremely difficult to identify exactly the same landmarks on all radiographs. The effect of these identification errors was investigated with simulations made on points of known three-dime...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446787

    authors: André B,Dansereau J,Labelle H

    更新日期:1992-11-01 00:00:00

  • Method for EMG conduction velocity estimation which accounts for input and output noise.

    abstract::A new technique is derived for estimating the conduction velocity of muscle fibre action potentials from surface EMG recordings in humans. The method is based on system identification and extends previous such methods by explicitly accounting for additive noise at the output as well as at the input. Experimental and s...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02446220

    authors: Rababy N,Kearney RE,Hunter IW

    更新日期:1989-03-01 00:00:00

  • Recording of physiological signals with domestic videotape storage.

    abstract::A system is presented for the recording of physiological signals on an unmodified domestic videocassette recorder (VCR). A modification in the vertical synchronism pulses permits the recording of continuous analogue signals without significant loss of samples. The system allows up to 16 input channels, with a maximum ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02447101

    authors: Salvador CH,Rosende P,González MA

    更新日期:1991-03-01 00:00:00

  • Multi-parametric study of temperature and thermal damage of tumor exposed to high-frequency nanosecond-pulsed electric fields based on finite element simulation.

    abstract::High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-016-1589-3

    authors: Mi Y,Rui S,Li C,Yao C,Xu J,Bian C,Tang X

    更新日期:2017-07-01 00:00:00

  • Clinically oriented real-time monitoring of the individual's risk for deep tissue injury.

    abstract::Spinal cord injury patients are under daily risk for developing deep tissue injury which is a severe pressure ulcer that initiates in soft tissues at the bones' proximity. We aimed to formulate a patient-specific biomechanical model that can continuously monitor internal tissue stresses in real time. We adopted a form...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-011-0754-y

    authors: Portnoy S,Vuillerme N,Payan Y,Gefen A

    更新日期:2011-04-01 00:00:00

  • Fluctuation analysis of respiratory impedance waveform in asthmatic patients: effect of airway obstruction.

    abstract::Fluctuation analysis has great potential to contribute to pulmonary clinical science and practice. We evaluated the relationship between asthma and the respiratory impedance recurrence period density entropy (RPDEnZrs) and the variability (SDZrs). A non-invasive and simple protocol for assessing respiratory mechanics ...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-012-0957-x

    authors: Veiga J,Lopes AJ,Jansen JM,Melo PL

    更新日期:2012-12-01 00:00:00

  • Electrical impedance tomography reconstruction algorithm based on general inversion theory and finite element method.

    abstract::A strict EIT reconstruction algorithm, the general inversion algorithm (GIA) is presented. To improve the noise performance, the algorithm is modified by attenuating the condition number of the forward matrix F and implemented using an improved FEM scheme, to obtain the 2D image of impedance change (dynamic image). Th...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02523205

    authors: Mengxing T,Xiuzhen D,Mingxin Q,Feng F,Xuetao S,Fusheng Y

    更新日期:1998-07-01 00:00:00

  • An adaptive enhancement method for breast X-ray images based on the nonsubsampled contourlet transform domain and whale optimization algorithm.

    abstract::We propose a new method for breast X-ray image adaptive enhancement that combines nonsubsampled contourlet transform (NSCT) with the whale optimization algorithm (WOA). First, the mammography X-ray image was processed by histogram equalization to ensure global image contrast. The processed image was then decomposed in...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-02022-w

    authors: Zhang CJ,Nie HH

    更新日期:2019-10-01 00:00:00

  • Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    abstract::Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, si...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02345448

    authors: Järverud K,Ollmar S,Brodin LA

    更新日期:2002-09-01 00:00:00

  • Numerical simulation of instantaneous backflow through central clearance of bileaflet mechanical heart valves at closure: shear stress and pressure fields within clearance.

    abstract::Instantaneous backflow through central clearance of bileaflet heart valves at the instant of closure is investigated. An Edwards-Duromedics valve in the mitral position is employed to measure the transient pressures near the entrance and exit region in an in vitro flow chamber. A region surrounding the clearance is mo...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/BF02510497

    authors: Lee CS,Chandran KB

    更新日期:1995-05-01 00:00:00

  • Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

    abstract::Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artifi...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-017-1752-5

    authors: Naidu SMM,Pandey PC,Bagal UR,Hardas SP

    更新日期:2018-06-01 00:00:00

  • Computational prediction of the effect of D172N KCNJ2 mutation on ventricular pumping during sinus rhythm and reentry.

    abstract::The understanding of cardiac arrhythmia under genetic mutations has grown in interest among researchers. Previous studies focused on the effect of the D172N mutation on electrophysiological behavior. In this study, we analyzed not only the electrophysiological activity but also the mechanical responses during normal s...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-020-02124-w

    authors: Heikhmakhtiar AK,Lee CH,Song KS,Lim KM

    更新日期:2020-05-01 00:00:00

  • Using a numerical method to precisely evaluate the alpha angle in a hip image.

    abstract::The alpha angle is a parameter extensively used to assess for cam-type femoroacetabular impingement (FAI) in a 2D image of the hip. As this angle requires estimation of the axis of the femoral neck, the drawing of this axis often results in measurement errors due to subjective judgment, influencing inter-rater and int...

    journal_title:Medical & biological engineering & computing

    pub_type: 杂志文章

    doi:10.1007/s11517-019-01973-4

    authors: Lai CL,Chi WM,Ho YJ,Lin CC,Lin HC,Kuo CL,Chen JH

    更新日期:2019-07-01 00:00:00