Abstract:
:Stroke survivors are more prone to developing cognitive impairment and dementia. Dementia detection is a challenge for supporting personalized healthcare. This study analyzes the electroencephalogram (EEG) background activity of 5 vascular dementia (VaD) patients, 15 stroke-related patients with mild cognitive impairment (MCI), and 15 control healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the discrimination of VaD, stroke-related MCI patients, and control subjects using fuzzy neighborhood preserving analysis with QR-decomposition (FNPAQR); second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. Nineteen channels were recorded and analyzed using the independent component analysis and wavelet analysis (ICA-WT) denoising technique. Using ANOVA, linear spectral power including relative powers (RP) and power ratio were calculated to test whether the EEG dominant frequencies were slowed down in VaD and stroke-related MCI patients. Non-linear features including permutation entropy (PerEn) and fractal dimension (FD) were used to test the degree of irregularity and complexity, which was significantly lower in patients with VaD and stroke-related MCI than that in control subjects (ANOVA; p ˂ 0.05). This study is the first to use fuzzy neighborhood preserving analysis with QR-decomposition (FNPAQR) dimensionality reduction technique with EEG background activity of dementia patients. The impairment of post-stroke patients was detected using support vector machine (SVM) and k-nearest neighbors (kNN) classifiers. A comparative study has been performed to check the effectiveness of using FNPAQR dimensionality reduction technique with the SVM and kNN classifiers. FNPAQR with SVM and kNN obtained 91.48 and 89.63% accuracy, respectively, whereas without using the FNPAQR exhibited 70 and 67.78% accuracy for SVM and kNN, respectively, in classifying VaD, stroke-related MCI, and control patients, respectively. Therefore, EEG could be a reliable index for inspecting concise markers that are sensitive to VaD and stroke-related MCI patients compared to control healthy subjects.
journal_name
Med Biol Eng Computjournal_title
Medical & biological engineering & computingauthors
Al-Qazzaz NK,Ali SHBM,Ahmad SA,Islam MS,Escudero Jdoi
10.1007/s11517-017-1734-7subject
Has Abstractpub_date
2018-01-01 00:00:00pages
137-157issue
1eissn
0140-0118issn
1741-0444pii
10.1007/s11517-017-1734-7journal_volume
56pub_type
杂志文章abstract::A hypothetical neuromusculoskeletal model is developed to simulate human normal walking and its modulated behaviors. A small set of neural periodic patterns drive spinal muscle synergies which in turn lead to specific pattern of muscle activation and supraspinal feedback systems maintain postural balance during walkin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0277-8
更新日期:2008-02-01 00:00:00
abstract::We introduce a novel method for an automatic classification of subjects to those with or without neuromuscular disorders. This method is based on multiscale entropy of recorded surface electromyograms (sEMGs) and support vector classification. The method was evaluated on a single-channel experimental sEMGs recorded fr...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-010-0629-7
更新日期:2010-08-01 00:00:00
abstract::It is clinically well-established that minimally invasive subcutaneous continuous glucose monitoring (CGM) sensors can significantly improve diabetes treatment. However, CGM readings are still not as reliable as those provided by standard fingerprick blood glucose (BG) meters. In addition to unavoidable random measure...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1226-y
更新日期:2015-12-01 00:00:00
abstract::A process is described for the fabrication of silicon-based microelectrodes for neurophysiology using bonded and etched-back silicon-on-insulator (BESOI) wafers. The probe shapes are defined without high levels of boron doping in the silicon; this is considered as a step towards producing probes with active electronic...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02344773
更新日期:2000-03-01 00:00:00
abstract::The recording of sounds over the orbit of the eye has been found to be useful in the detection of intracranial aneurysms. A hydrophone for auscultation over the eye has been developed and is tested under controlled conditions. The tests consist of measurement over the eyes in three healthy volunteers at rest, during v...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02523031
更新日期:1995-03-01 00:00:00
abstract::Quantitative sensory testing (QST) can provide useful information about the underlying mechanisms involved in chronic pain. However, currently available devices typically employed suffer from operator-dependent effects, or are too cumbersome for routine clinical care. This paper presents the design and initial validat...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-013-1033-x
更新日期:2013-06-01 00:00:00
abstract::The first in vivo evaluation of a pO2 sensor constructed with a novel copolymer is described. The performance of the sensor is assessed under dynamic conditions in vitro and in vivo. This sensor is more stable and reliable than the control sensor with a heparin-treated polyethylene membrane. ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02511245
更新日期:1996-07-01 00:00:00
abstract::Biological variation in branching patterns is likely to affect perfusion of tissue. To assess the fundamental consequences of branching characteristics, 50 stochastic asymmetrical coronary trees and one non-stochastic symmetrical branching tree were generated. In the stochastic trees, area growth, A, at branching poin...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-006-0139-9
更新日期:2007-01-01 00:00:00
abstract::Magnetoenterography (MENG) is a new, non-invasive technique that measures gastrointestinal magnetic signals near the body surface. This study was undertaken to evaluate the temporal and spatial characteristics of the magnetic signals generated by gastric and duodenal slow wave activity. The gastrointestinal magnetic f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02513347
更新日期:1999-09-01 00:00:00
abstract::Neurofilaments are organised into parallel bundles in axons through crossbridges formed by lateral projections of neurofilament subunits. Pure neurofilaments form gels in vitro, consisting of interconnected parallel arrays of filaments regulated by the phosphorylation level of neurofilament subunits. Neurofilament-ass...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522486
更新日期:1998-05-01 00:00:00
abstract::The present study describes a new methodological approach which allows the separate analysis and quantitative determination of the viscous and elastic components of human hair using a computerised experimental system. In a first series of experiments subsequent to the estimation of the cross-sectional surface area of ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446198
更新日期:1992-01-01 00:00:00
abstract::While matrix remodeling plays a key role in vascular physiology and pathology, the underlying mechanisms have remained incompletely understood. We studied the remodeling of collagen matrices by individual vascular smooth muscle cells (SMCs), clusters and monolayers. In addition, we focused on the contribution of trans...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-0916-6
更新日期:2012-07-01 00:00:00
abstract::Successful identification of gastric slow waves in canine gastric electrical activity (GEA) data was achieved using a statistical data-processing procedure based on the multiple linear regression (MLR) curve fitting technique. Both distal and proximal waveforms were identified, first by construction of separate orthon...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345076
更新日期:2002-07-01 00:00:00
abstract::In the PREVENIR-5 study, artificial neural networks (NN) were applied to a large sample of patients with recent first acute coronary syndrome (ACS) to identify determinants of persistence of evidence-based cardiovascular medications (EBCM: antithrombotic + beta-blocker + statin + angiotensin converting enzyme inhibito...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0785-4
更新日期:2011-08-01 00:00:00
abstract::Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficu...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02345957
更新日期:2005-03-01 00:00:00
abstract::The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocyt...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-009-0552-y
更新日期:2010-01-01 00:00:00
abstract::In total hip arthroplasty, determining the impingement free range of motion requirement is a complex task. This is because in the native hip, motion is restricted by both impingement as well as soft tissue restraint. The aim of this study is to determine a range of motion benchmark which can identify motions which are...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-012-1016-3
更新日期:2013-04-01 00:00:00
abstract::A rapid-access but limited vocabulary communication aid for the non-vocal and speech impaired is useful in some well defined situations. The design and construction of such a device is described. Three distinct situations have been identified where an aid is essential and an initial evaluation has shown the Pocket Spe...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441487
更新日期:1989-05-01 00:00:00
abstract::Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel inte...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-011-0741-3
更新日期:2011-04-01 00:00:00
abstract::A system, to collect, analyse and display biological data, is developed using IBM PC AT compatibles (PCs) or CED1401/1609 devices networked to a VAX environment. It can be operated in three separate modes: using the CED/IEEE/VAX network; using the PC/Ethernet/VAX network; as a standalone PC. The original system compri...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446881
更新日期:1993-01-01 00:00:00
abstract::When the microvascular blood perfusion in human skin is measured by photoplethysmography (PPG), infra-red light (800-960 nm) is normally used as the light source. The PPG signal, which consists of a pulsatile (AC) and a slowly fluctuating (DC) component, was studied at different optical wavelengths utilising optical f...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02446295
更新日期:1991-01-01 00:00:00
abstract::Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibil...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-01995-y
更新日期:2019-08-01 00:00:00
abstract::Left ventricular assist devices (LVAD) emerges as an effective clinical device providing life-saving support to heart patients. The design of blood pump of an LVAD involves incredible accuracy and thorough understanding of hemodynamics to mimic the functionality of a healthy ventricle. This work studies hemodynamics a...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-019-02097-5
更新日期:2020-02-01 00:00:00
abstract::The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMG(MIC)) and an accelerometer (MMG(ACC)) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3...
journal_title:Medical & biological engineering & computing
pub_type: 临床试验,杂志文章
doi:10.1007/s11517-006-0036-2
更新日期:2006-04-01 00:00:00
abstract::When the rib cage and abdomen are compressed during cardiopulmonary resuscitation (CPR), the effect on intrathoracic pressure, and therefore on haemodynamics, cannot be quantitatively predicted without a physiologically based mathematical model of chest wall dynamics. Using such a model, we compared model simulations ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02441676
更新日期:1990-01-01 00:00:00
abstract::Very few computer models of the spine integrate vertebral growth plates to investigate their mechanical behavior and potential impacts on bone growth. An approach was developed to generate a finite element (FE) model of the lumbar spine and their connective tissues including the growth plate, which allowed a personali...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0220-z
更新日期:2007-10-01 00:00:00
abstract::Left ventricular assist device (LVAD) support unloads left ventricular (LV) pressure and volume and decreases wall stress. This study investigated the effect of systematic LVAD unloading on the 3-dimensional myocardial wall stress by employing finite element models containing layered fiber structure, active contractil...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-014-1205-3
更新日期:2014-12-01 00:00:00
abstract::A computational model of the fluid dynamics of intraventricular flow was used to investigate the importance of the effects of flow disturbances existing within the left ventricle (LV) at the onset of diastole on a diastolic flow field. The simulation started with a quiescent flow state; it continued for a number of ca...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02350992
更新日期:2004-07-01 00:00:00
abstract::The role of alveolar macrophages in the process of the human lung clearance is summarised. Three patterns of alveolar macrophage (AM) displacement on the surface of alveolus are distinguished depending on the loading of the surface with insoluble deposits, i.e. directional, directional with small stochastic noise and ...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/BF02522517
更新日期:1995-07-01 00:00:00
abstract::The surface electroenterogram (EEnG) is a non-invasive method of studying myoelectrical bowel activity. However, surface EEnG recordings are contaminated by cardiac activity, respiratory and motion artifacts, and other sources of interference. The aim of this work is to remove the respiration artifact and the very low...
journal_title:Medical & biological engineering & computing
pub_type: 杂志文章
doi:10.1007/s11517-007-0189-7
更新日期:2007-06-01 00:00:00