Isotopic analogues as internal standards for quantitative analyses of drugs and metabolites by GC-MS--nonlinear calibration approaches.

Abstract:

:In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contribution (contribution of the IS to the intensity of the ion designated for the analyte and vice versa) on the linearity of the calibration data are examined. Nonlinear approaches that may address this problem are also studied. Two ion pairs (one with least and one with significant cross-contribution) from each of the following analyte/IS pairs are used as the exemplar systems for this study: butalbital/13C4-butalbital, butalbital/2H5-butalbital, secobarbital/13C4-secobarbital, and secobarbital/2H5-secobarbital. Analyte/IS ion intensity ratios of a series of standard solutions are correlated with the analyte/IS concentration ratios using one-point, multiple-point (unweighted and weighted) linear, and hyperbolic functions. The one-point calibration approach produces excellent calibration results in treating data derived from ion pairs with no significant cross contribution. In cases where significant cross-contribution exists, results derived from the one-point approach show, as expected, significant deviations at both ends of the concentration range. With the cross-contribution phenomenon accounted for, the hyperbolic calibration model is clearly more effective in fitting calibration data at both the lower and higher analyte concentration ends, thus significantly lowering the detection limit and extending the calibration range to a higher level. However, the calibration range cannot be extended indefinitely. At the low concentration end, noise-to-signal ratio and the cross-contribution of the IS to the intensity of the ion designated for the analyte, however insignificant, will incrementally reduce the quality of the observed ion intensity and intensity ratio data. At the high concentration end, detection saturation and the cross-contribution of the analyte to the intensity of the ion designated for the IS, however insignificant, will incrementally decrease the "slope" of the calibration curve. Thus, acceptable sensitivity (increase in analyte/IS ion-pair intensity ratio per unit increase in analyte concentration) of the calibration curve will become the limiting factor.

journal_name

J Anal Toxicol

authors

Whiting TC,Liu RH,Chang WT,Bodapati MR

doi

10.1093/jat/25.3.179

keywords:

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

179-89

issue

3

eissn

0146-4760

issn

1945-2403

journal_volume

25

pub_type

杂志文章
  • Cannabinoid concentrations in spot serum samples 24-48 hours after discontinuation of cannabis smoking.

    abstract::A blood concentration of tetrahydrocannabinol (THC) in the low nanograms-per-milliliter range is often claimed to result from drug use more than 24-48 h previously. The present investigation determined concentrations of cannabinoids in blood collected at least 24 h from smoking in an in-patient setting. During samplin...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/32.2.160

    authors: Skopp G,Pötsch L

    更新日期:2008-03-01 00:00:00

  • A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    abstract::A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.1.36

    authors: Ishii A,Seno H,Suzuki O,Hattori H,Kumazawa T

    更新日期:1997-01-01 00:00:00

  • Direct determination of ethyl glucuronide and ethyl sulfate in postmortem urine specimens using hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry.

    abstract::This work was aimed at developing and validating a hydrophilic interaction chromatography (HILIC)-electrospray ionization (ESI)-ion trap-tandem mass spectrometric method for identification and quantification of ethyl glucuronide (ETG) and ethyl sulfate (ETS) as ethanol biomarkers and at employing this method for analy...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/34.5.261

    authors: Al-Asmari AI,Anderson RA,Appelblad P

    更新日期:2010-06-01 00:00:00

  • Stability and Degradation Pathways of Different Psychoactive Drugs in Neat and in Buffered Oral Fluid.

    abstract::Sampling and drug stability in oral fluid (OF) are crucial factors when interpreting forensic toxicological analysis, mainly because samples may not be analyzed immediately after collection, potentially altering drug concentrations. Therefore, the stability of some common drugs of abuse (morphine, codeine, 6-monoacety...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkz114

    authors: Marchei E,Malaca S,Graziano S,Gottardi M,Pichini S,Busardò FP

    更新日期:2020-07-31 00:00:00

  • Quantitative analysis of benzene by selected ion monitoring/gas chromatography/mass spectrometry.

    abstract::A selected ion monitoring gas chromatographic/mass spectrometric method for the quantitative determination of benzene in air, breath, and blood was developed utilizing a headspace assay with benzene-d3 as an internal standard. Limits of detection for 2 ng/mL in blood and 0.1 ppb in a 5-L sample of air or breath were a...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/10.6.225

    authors: Gruenke LD,Craig JC,Wester RC,Maibach HI

    更新日期:1986-11-01 00:00:00

  • Specific determination of cyanide in blood by headspace gas chromatography.

    abstract::An improved method has been developed for the quantitative determination of cyanide in human blood by headspace gas chromatography with electron-capture detection. In this novel method, cyanide was detected after conversion of hydrogen cyanide into cyanogen chloride by a reaction with chloramine T. The advantage of th...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/18.4.205

    authors: Odoul M,Fouillet B,Nouri B,Chambon R,Chambon P

    更新日期:1994-07-01 00:00:00

  • An HPLC method for the quantitation of quinidine and its metabolites in plasma: an application to a quinidine-phenytoin drug interaction study.

    abstract::A rapid and simple method is described for the separation of quinidine (Q), its metabolites 3-hydroxyquinidine (30HQ) and 2'oxoquinidinone (QD) as well as the quinidine salt contaminant, dihydroquinidine (DHQ) in plasma by high pressure liquid chromatography (HPLC). A silica column was used with methanol: 1 N ammonium...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/6.3.153

    authors: Pershing LK,Peat MA,Finkle BS

    更新日期:1982-05-01 00:00:00

  • Evaluation of potential lactate/lactate dehydrogenase interference with an enzymatic alcohol analysis.

    abstract::The Connecticut Department of Public Safety laboratory recently addressed a legal challenge to a hospital alcohol dehydrogenase (ADH)-based serum ethanol determination based on the suggestion of interference by lactate dehydrogenase (LDH)-catalyzed oxidation of lactate. Both ADH- and LDH-oxidations require NAD(+) (pre...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/33.8.561

    authors: Powers RH,Dean DE

    更新日期:2009-10-01 00:00:00

  • Detection Time of Oxazepam and Zopiclone in Urine and Oral Fluid after Experimental Oral Dosing.

    abstract::Data from previous experimental studies on the detection time of oxazepam and zopiclone in biological matrices are limited. The aim of this study was to examine the detection time in urine and oral fluid after single oral doses of oxazepam and zopiclone. Ten healthy volunteers received 25 mg of oxazepam in the evening...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bky083

    authors: Bruun LD,Kjeldstadli K,Temte V,Birdal M,Bachs L,Langødegård M,Strand DH,Gaare KI,Øiestad E,Høiseth G

    更新日期:2019-06-01 00:00:00

  • Validation of blood and liver oxymorphone analysis using LC-MS-MS: concentrations in 30 fatal overdoses.

    abstract::A sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitation of oxymorphone (OM) in human whole blood and liver. Sample preparation was done by solid-phase extraction, using deuterated OM as the internal standard. Separation was achieved using a Waters Aquity UPLC ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkt077

    authors: Crum ED,Bailey KM,Richards-Waugh LL,Clay DJ,Gebhardt MA,Kraner JC

    更新日期:2013-10-01 00:00:00

  • Determination of naltrexone and 6-beta-naltrexol in plasma by solid-phase extraction and gas chromatography-negative ion chemical ionization-mass spectrometry.

    abstract::Solid-phase extraction (SPE) and a one-step derivatization are combined with gas chromatography-negative ion chemical ionization-mass spectrometry to simplify a previously reported method for the determination of naltrexone and its metabolite, 6-beta-naltrexol, in human plasma. Deuterated isotopomers of naltrexone and...

    journal_title:Journal of analytical toxicology

    pub_type: 临床试验,杂志文章

    doi:10.1093/jat/21.4.252

    authors: Huang W,Moody DE,Foltz RL,Walsh SL

    更新日期:1997-07-01 00:00:00

  • Determination of arsenic in fish by hydride generation atomic absorption spectrometry.

    abstract::A method utilizing microwave dissolution in a closed Teflon bomb followed by hydride generation atomic absorption spectrometry has been used for the routine analysis of arsenic in fish species from the coast of the province of Granada, Spain. The technique was evaluated for decomposing biological standard reference ma...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/16.3.169

    authors: Navarro M,López H,López MC,Sánchez M

    更新日期:1992-05-01 00:00:00

  • Trazodone overdose: report of two cases.

    abstract::Two cases of overdose due to ingestion of trazodone are described. In one case, blood collected several hours following ingestion of an estimated 4 or more grams contained a trazodone concentration of 25.7 mg/L. Recovery was uneventful. The second case did not survive and death was attributed to the ingestion of multi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/8.2.91

    authors: Root I,Ohlson GB

    更新日期:1984-03-01 00:00:00

  • Measurement of carbamazepine and its main biotransformation products in plasma by HPLC.

    abstract::We present a method that permits the simultaneous analysis of carbamazepine (CBZ) and its major biotransformation products, carbamazepine-10,11-epoxide (CBZ-E) and carbamazepine-10,11-dihydroxide (CBZ-diOH), in plasma samples. The method consists of plasma extraction in alkaline medium with NaCl added using chloroform...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/16.2.88

    authors: Bonato PS,Lanchote VL,de Carvalho D,Achê P

    更新日期:1992-03-01 00:00:00

  • Resorcylic Acid Lactones in Urine Samples of Croatian Farm Animals.

    abstract::Metabolic transformation of zearalenone (ZEA), a mycotoxin which can contaminate both food and feed, results in the formation of five metabolites, one of them being zeranol (α-ZAL), which can be abused in farm animals as a growth promoter. To the best of our knowledge, there is no analytical method that can distinguis...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bky069

    authors: Vulić A,Lešić T,Kudumija N,Mikuš T,Pleadin J

    更新日期:2019-03-01 00:00:00

  • The stability of ethanol in human whole blood controls: an interlaboratory evaluation.

    abstract::Sterile whole human blood control materials were commercially prepared in batches containing anticoagulants and preservatives and approximately 90, 150, and 230 mg/dL ethanol with and without 0.3% (w/v) sodium azide. Aliquots in sealed vials were stored by the manufacturer at 2-8 degrees C until shipped monthly to thr...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.6.486

    authors: Dubowski KM,Gadsden RH Sr,Poklis A

    更新日期:1997-10-01 00:00:00

  • Tabulation of alcohol content of beer and malt beverages.

    abstract::We present data from the analysis of the alcohol content of 391 beers and malt beverages available for sale in the State of Washington. The beverages were tested by gas chromatography for their alcohol content. Considerable variability in the alcoholic strength was found, even within the same class. Overall, the range...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/24.3.202

    authors: Case GA,Distefano S,Logan BK

    更新日期:2000-04-01 00:00:00

  • Acute Methiopropamine Intoxication After "Synthacaine" Consumption.

    abstract::Use of methiopropamine (MPA), a synthetic metamfetamine analog, has been detected since 2011 in Europe, but there is limited information on its acute toxicity. A 30-year-old man was admitted to the emergency department in a confused state, with paranoid delusion, auditory and visual hallucinatory experiences, and inco...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkw073

    authors: Daveluy A,Castaing N,Cherifi H,Richeval C,Humbert L,Faure I,Labadie M,Allorge D,Haramburu F,Molimard M,Titier K

    更新日期:2016-11-01 00:00:00

  • Quantitation of barbiturates by a modification of the EMIT-tox serum barbiturate assay.

    abstract::A modification of the Syva EMIT-tox Serum Barbiturate Assay was developed to provide a rapid and practical method for quantitating serum barbiturates. Standard curves for eight selected barbiturates were run using specific sets of standards for each. Correlation coefficients, slopes, and y-intercepts for the curves of...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/7.6.257

    authors: Watson AT,Manno JE,Manno BR

    更新日期:1983-11-01 00:00:00

  • The Lethal Cutting: An Unexpected Cause of Death.

    abstract::Cocaine is among the illicit substances most frequently implicated in deaths related to the use of drugs of abuse both worldwide and in Italy. Cutting agents involved in the adulterations of this substance are many and the process of lacing can take place at various stages of the production of the drug. In this Report...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkab006

    authors: Di Candia D,Boracchi M,Muccino E,Gentile G,Zoja R

    更新日期:2021-01-08 00:00:00

  • Duragesic transdermal patch: postmortem tissue distribution of fentanyl in 25 cases.

    abstract::Fentanyl is a potent, short-acting narcotic analgesic widely used as a surgical anesthetic and for the control of pain when administered in the form of a transdermal patch. The success of the patch can be attributed to fentanyl's low molecular weight and its highly lipophilic nature, which enables it to be readily abs...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/24.7.627

    authors: Anderson DT,Muto JJ

    更新日期:2000-10-01 00:00:00

  • Postmortem morphine concentrations following use of a continuous infusion pump.

    abstract::We report a case involving unusually high postmortem morphine concentrations in a 44-year-old male with end-stage pancreatic cancer. He was receiving morphine for pain control via a single subclavian intravenous catheter. Allegations of foul play were made by family members at the time of death, so a full autopsy was ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/28.6.529

    authors: Kerrigan S,Honey D,Baker G

    更新日期:2004-09-01 00:00:00

  • Determination of phenol and pentachlorophenol in plasma and urine samples by gas liquid chromatography.

    abstract::Gas chromatographic methods have been developed using a Supelco 1240-DA column for the determination of pentachlorophenol (PCP) in plasma and urine samples, and phenol in urine samples. These methods required no derivatization. Electron capture detection has been used for PCP determination, while flame ionization dete...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/6.6.297

    authors: Rick DL,Licht CF,McCarty LP

    更新日期:1982-11-01 00:00:00

  • A comparison of ethanolamine and potassium hydroxide as quantitative trapping agents for radiolabeled CO2 in metabolism studies.

    abstract::The efficiency of ethanolamine and potassium hydroxide (KOH) as trapping agents for CO2 was determined using a flow of 500 mL/min through CO2 absorption towers containing trapping solutions. Radiolabeled 14CO2 was produced by acidification of suspensions containing Ba14CO3. Both 100% ethanolamine and 5M ethanolamine i...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/10.1.24

    authors: Medinsky MA

    更新日期:1986-01-01 00:00:00

  • Gas chromatographic determination of urinary o-cresol for the monitoring of toluene exposure.

    abstract::A sensitive and reproducible gas chromatographic procedure for the quantitative determination of urinary o-cresol is described. The first step involves acid hydrolysis (2N HCl, 100 degrees C, 10 min), which yields unconjugated o-cresol. After extraction (methylene chloride, pH 2), the organic layer is concentrated by ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/20.5.309

    authors: Truchon G,Tardif R,Brodeur J

    更新日期:1996-09-01 00:00:00

  • Simultaneous determination of eight anticoagulant rodenticides in blood serum and liver.

    abstract::A liquid chromatographic method was developed for the analysis of indandione and 4-hydroxycoumarin anticoagulant rodenticides in blood serum and liver. The method enabled the measurement of serum and liver concentrations of eight anticoagulant rodenticides: brodifacoum, bromadiolone, chlorophacinone, coumafuryl, couma...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/17.1.56

    authors: Chalermchaikit T,Felice LJ,Murphy MJ

    更新日期:1993-01-01 00:00:00

  • Identification of diuron and four of its metabolites in human postmortem plasma and urine by LC/MS with a moving-belt interface.

    abstract::Unknown compounds that were not amenable to GC/MS were found during routine benzodiazepine HPLC screening in a postmortem case. The apparent thermolability made the application of liquid chromatography with mass spectrometry mandatory. The moving-belt interface was used because of its value for identification based on...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/13.1.8

    authors: Verheij ER,van der Greef J,La Vos GF,van der Pol W,Niessen WM

    更新日期:1989-01-01 00:00:00

  • Determination of SCN--in vegetables by gas chromatography in relation to endemic goiter.

    abstract::The quantity of thiocyanate ion in vegetables has been determined due to its relationship with endemic goiter. The technique is based on the use of gas chromatography with electron capture detection (ECD), which provides good sensitivities. ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/12.6.307

    authors: Olea Serrano MR,Ruiz Lopez MD,Justica Palomares H

    更新日期:1988-11-01 00:00:00

  • Cobas Mira S endpoint enzymatic assay for plasma formate.

    abstract::In methanol intoxication, increased levels of the metabolite formate are associated with metabolic acidosis and an increased risk for ocular and neurological dysfunction. A simple method for plasma formate measurement by adaptation of a manual enzymatic assay to a Cobas Mira S analyzer is presented. Six microliters of...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/25.2.77

    authors: Blomme B,Lheureux P,Gerlo E,Maes V

    更新日期:2001-03-01 00:00:00

  • The analysis of cocaine and benzoylecgonine in meconium.

    abstract::We describe an assay for measuring cocaine and benzoylecgonine in meconium of infants born to mothers suspected of using cocaine during their pregnancy. The assay involves the use of fluorescence polarization immunoassay (FPIA) to screen for benzoylecgonine in a methanolic extract of the meconium. The FPIA is sensitiv...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/16.4.261

    authors: Clark GD,Rosenzweig IB,Raisys V,Callahan CM,Grant TM,Streissguth AP

    更新日期:1992-07-01 00:00:00