Attention to Lesion: Lesion-Aware Convolutional Neural Network for Retinal Optical Coherence Tomography Image Classification.

Abstract:

:Automatic and accurate classification of retinal optical coherence tomography (OCT) images is essential to assist ophthalmologist in the diagnosis and grading of macular diseases. Clinically, ophthalmologists usually diagnose macular diseases according to the structures of macular lesions, whose morphologies, size, and numbers are important criteria. In this paper, we propose a novel lesion-aware convolutional neural network (LACNN) method for retinal OCT image classification, in which retinal lesions within OCT images are utilized to guide the CNN to achieve more accurate classification. The LACNN simulates the ophthalmologists' diagnosis that focuses on local lesion-related regions when analyzing the OCT image. Specifically, we first design a lesion detection network to generate a soft attention map from the whole OCT image. The attention map is then incorporated into a classification network to weight the contributions of local convolutional representations. Guided by the lesion attention map, the classification network can utilize the information from local lesion-related regions to further accelerate the network training process and improve the OCT classification. Our experimental results on two clinically acquired OCT datasets demonstrate the effectiveness and efficiency of the proposed LACNN method for retinal OCT image classification.

journal_name

IEEE Trans Med Imaging

authors

Fang L,Wang C,Li S,Rabbani H,Chen X,Liu Z

doi

10.1109/TMI.2019.2898414

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

1959-1970

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

38

pub_type

杂志文章
  • Toward Intra-Operative Prostate Photoacoustic Imaging: Configuration Evaluation and Implementation Using the da Vinci Research Kit.

    abstract::We compare different possible scanning geometries for prostate photoacoustic tomography (PAT) while considering a realistic reconstruction scenario in which the limited view of the prostate and the directivity effect of the transducer are considered. Simulations and experiments confirm that an intra-operative configur...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2855166

    authors: Moradi H,Tang S,Salcudean SE

    更新日期:2019-01-01 00:00:00

  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • Detecting film-screen artifacts in mammography using a model-based approach.

    abstract::Microcalcifications can be one of the earliest signs of breast cancer. Unfortunately, their appearance in mammograms can be mimicked by dust and dirt entering the imaging process and this has been shown previously to lead to false positives. We use a model of the imaging process and, in particular, the blurring functi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.811313

    authors: Highnam R,Brady M,English R

    更新日期:1999-10-01 00:00:00

  • Difference-Frequency Ultrasound Imaging With Non-Linear Contrast.

    abstract::Conventional ultrasound imaging is based on the scattering of sound from inhomogeneities in the density and the speed of sound and is often used in medicine to resolve pathologic compared to normal tissue. Here we demonstrate a difference-frequency ultrasound (dfUS) imaging method that is based on the interaction of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2957280

    authors: Li Y,Polyak D,Johnson E,Yecies D,Shevidi S,de la Zerda A,Gephart MH,Chu S

    更新日期:2020-05-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • Time delay for arrival of MR contrast agent in collateral-dependent myocardium.

    abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.827969

    authors: Jerosch-Herold M,Hu X,Murthy NS,Seethamraju RT

    更新日期:2004-07-01 00:00:00

  • Metrics for Assessing the Similarity of Microwave Breast Imaging Scans of Healthy Volunteers.

    abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2806878

    authors: Lavoie BR,Bourqui J,Fear EC,Okoniewski M

    更新日期:2018-08-01 00:00:00

  • A system for real-time XMR guided cardiovascular intervention.

    abstract::The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.856731

    authors: Rhode KS,Sermesant M,Brogan D,Hegde S,Hipwell J,Lambiase P,Rosenthal E,Bucknall C,Qureshi SA,Gill JS,Razavi R,Hill DL

    更新日期:2005-11-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00

  • A geometric method for automatic extraction of sulcal fundi.

    abstract::Sulcal fundi are 3-D curves that lie in the depths of the cerebral cortex and, in addition to their intrinsic value in brain research, are often used as landmarks for downstream computations in brain imaging. In this paper, we present a geometric algorithm that automatically extracts the sulcal fundi from magnetic res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.886810

    authors: Kao CY,Hofer M,Sapiro G,Stem J,Rehm K,Rottenberg DA

    更新日期:2007-04-01 00:00:00

  • MRI-compatible device for examining brain activation related to stepping.

    abstract::Repetitive and alternating lower limb movements are a specific component of human gait. Due to technical challenges, the neural mechanisms underlying such movements have not been previously studied with functional magnetic resonance imaging. In this study, we present a novel treadmill device employed to investigate th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2301493

    authors: Martinez M,Villagra F,Loayza F,Vidorreta M,Arrondo G,Luis E,Diaz J,Echeverria M,Fernandez-Seara MA,Pastor MA

    更新日期:2014-05-01 00:00:00

  • Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

    abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015079

    authors: Zeraatkar N,Kalluri KS,Auer B,Konik A,Fromme TJ,Furenlid LR,Kuo PH,King MA

    更新日期:2020-12-01 00:00:00

  • Exact radon rebinning algorithm for the long object problem in helical cone-beam CT.

    abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870247

    authors: Schaller S,Sauer F,Tam KC,Lauritsch G,Flohr T

    更新日期:2000-05-01 00:00:00

  • Semiautomated border tracking of cine echocardiographic ventnrcular images.

    abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307836

    authors: Adam D,Hareuveni O,Sideman S

    更新日期:1987-01-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • Topology-based kernels with application to inference problems in Alzheimer's disease.

    abstract::Alzheimer's disease (AD) research has recently witnessed a great deal of activity focused on developing new statistical learning tools for automated inference using imaging data. The workhorse for many of these techniques is the support vector machine (SVM) framework (or more generally kernel-based methods). Most of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2147327

    authors: Pachauri D,Hinrichs C,Chung MK,Johnson SC,Singh V

    更新日期:2011-10-01 00:00:00

  • Pubic arch detection in transrectal ultrasound guided prostate cancer therapy.

    abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736032

    authors: Pathak SD,Grimm PD,Chalana V,Kim Y

    更新日期:1998-10-01 00:00:00

  • Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

    abstract::Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.801171

    authors: Xu Y,Xu M,Wang LV

    更新日期:2002-07-01 00:00:00

  • Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator.

    abstract::While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699672

    authors: Tremblay-Darveau C,Bar-Zion A,Williams R,Sheeran PS,Milot L,Loupas T,Adam D,Bruce M,Burns PN

    更新日期:2017-09-01 00:00:00

  • Optimizing rod window width in positron emission tomography.

    abstract::A technique determines the optimal window width for orbiting rod transmission studies in positron emission tomography (PET). Windowing reduces noise in orbiting rod transmission studies. Lines-of-response (LOR) which intersect the rods generate primarily true coincidence events. LOR which pass far from the rods genera...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.387708

    authors: Jones WF,Digby WM,Luk WK,Casey ME,Byars LG

    更新日期:1995-01-01 00:00:00

  • A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

    abstract::A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.668698

    authors: Sled JG,Zijdenbos AP,Evans AC

    更新日期:1998-02-01 00:00:00

  • Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

    abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899328

    authors: Fang Z,Chen Y,Liu M,Xiang L,Zhang Q,Wang Q,Lin W,Shen D

    更新日期:2019-10-01 00:00:00

  • Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring.

    abstract::Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used as the input to a simpl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2532122

    authors: Kallenberg M,Petersen K,Nielsen M,Ng AY,Pengfei Diao,Igel C,Vachon CM,Holland K,Winkel RR,Karssemeijer N,Lillholm M

    更新日期:2016-05-01 00:00:00

  • The n-PI-method for helical cone-beam CT.

    abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.887834

    authors: Proksa R,Köhler T,Grass M,Timmer J

    更新日期:2000-09-01 00:00:00

  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • A method for modeling noise in medical images.

    abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.832656

    authors: Gravel P,Beaudoin G,De Guise JA

    更新日期:2004-10-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00