Metrics for Assessing the Similarity of Microwave Breast Imaging Scans of Healthy Volunteers.

Abstract:

:Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address this issue, we compare the effectiveness of six different measures of image similarity for quantifying the similarity (or difference) between two microwave radar images. The structural similarity index has become the de facto standard for image comparison, but we propose that useful information can be acquired from a measure known as the Modified Hausdorff Distance. We apply each measure to image pairs from sequential scans of both phantoms and volunteers. We find that rather than using a single value to quantify the image similarity, by computing a number of values that are designed to capture different image aspects, we can better assess the ways in which the images differ.

journal_name

IEEE Trans Med Imaging

authors

Lavoie BR,Bourqui J,Fear EC,Okoniewski M

doi

10.1109/TMI.2018.2806878

subject

Has Abstract

pub_date

2018-08-01 00:00:00

pages

1788-1798

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

37

pub_type

杂志文章
  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches.

    abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2894349

    authors: Hussein S,Kandel P,Bolan CW,Wallace MB,Bagci U

    更新日期:2019-08-01 00:00:00

  • Border detection on digitized skin tumor images.

    abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.896789

    authors: Zhang Z,Stoecker WV,Moss RH

    更新日期:2000-11-01 00:00:00

  • Augmented Likelihood Image Reconstruction.

    abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2459764

    authors: Stille M,Kleine M,Hägele J,Barkhausen J,Buzug TM

    更新日期:2016-01-01 00:00:00

  • Robust Empirical Bayesian Reconstruction of Distributed Sources for Electromagnetic Brain Imaging.

    abstract::Electromagnetic brain imaging is the reconstruction of brain activity from non-invasive recordings of the magnetic fields and electric potentials. An enduring challenge in this imaging modality is estimating the number, location, and time course of sources, especially for the reconstruction of distributed brain source...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2932290

    authors: Cai C,Diwakar M,Chen D,Sekihara K,Nagarajan SS

    更新日期:2020-03-01 00:00:00

  • Iterative image reconstruction using inverse fourier rebinning for fully 3-D PET.

    abstract::We describe a fast forward and back projector pair based on inverse Fourier rebinning for use in iterative image reconstruction for fully three-dimensional (3-D) positron emission tomography (PET). The projector pair is used as part of a factored system matrix that takes into account detector-pair response by using sh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:

    authors: Cho S,Li Q,Ahn S,Bai B,Leahy RM

    更新日期:2007-03-01 00:00:00

  • High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation.

    abstract::High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging w...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2523346

    authors: Poree J,Posada D,Hodzic A,Tournoux F,Cloutier G,Garcia D

    更新日期:2016-07-01 00:00:00

  • Amplified Flow Imaging (aFlow): A Novel MRI-Based Tool to Unravel the Coupled Dynamics Between the Human Brain and Cerebrovasculature.

    abstract::With each heartbeat, periodic variations in arterial blood pressure are transmitted along the vasculature, resulting in localized deformations of the arterial wall and its surrounding tissue. Quantification of such motions may help understand various cerebrovascular conditions, yet it has proven technically challengin...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3012932

    authors: Abderezaei J,Martinez J,Terem I,Fabris G,Pionteck A,Yang Y,Holdsworth SJ,Nael K,Kurt M

    更新日期:2020-12-01 00:00:00

  • Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy.

    abstract::Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We prese...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2609888

    authors: Fischer P,Pohl T,Faranesh A,Maier A,Hornegger J

    更新日期:2017-04-01 00:00:00

  • Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

    abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899328

    authors: Fang Z,Chen Y,Liu M,Xiang L,Zhang Q,Wang Q,Lin W,Shen D

    更新日期:2019-10-01 00:00:00

  • Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography.

    abstract::This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Fel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.876147

    authors: Schäfer D,Borgert J,Rasche V,Grass M

    更新日期:2006-07-01 00:00:00

  • The detection and quantification of retinopathy using digital angiograms.

    abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363106

    authors: Zhou L,Rzeszotarski MS,Singerman LJ,Chokreff JM

    更新日期:1994-01-01 00:00:00

  • Improvement of Chest Region CT Images through Automated Gray-Level Remapping.

    abstract::A software system, CTIP, written in Fortran is discussed which remaps the computerized tomography (CT) image gray level so that both the lung and heart regions are clearly visible with a "natural anatomical appearance." The system is adaptive to image statistics derived from the gray-level histogram of the entire imag...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307736

    authors: Davis G,Wallenslager ST

    更新日期:1986-01-01 00:00:00

  • A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications.

    abstract::A capacitive impedance metasurface combined with a transceiver coil to improve the radio frequency magnetic field for 1.5T magnetic resonance imaging applications is presented. The novel transceiver provides localized enhancement in magnetic flux density when compared to a transceiver coil alone by incorporating an el...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2942194

    authors: Issa I,Ford KL,Rao M,Wild JM

    更新日期:2020-04-01 00:00:00

  • Repeatability of linear and nonlinear elastic modulus maps from repeat scans in the breast.

    abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3036032

    authors: Gendin DI,Nayak R,Wang Y,Bayat M,Fazzio RT,Oberai AA,Hall TJ,Barbone PE,Alizad A,Fatemi M

    更新日期:2020-11-05 00:00:00

  • The fuzzy Hough transform-feature extraction in medical images.

    abstract::Identification of anatomical features is a necessary step for medical image analysis. Automatic methods for feature identification using conventional pattern recognition techniques typically classify an object as a member of a predefined class of objects, but do not attempt to recover the exact or approximate shape of...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293916

    authors: Philip KP,Dove EL,McPherson DD,Gotteiner NL,Stanford W,Chandran KB

    更新日期:1994-01-01 00:00:00

  • Discriminative segmentation-based evaluation through shape dissimilarity.

    abstract::Segmentation-based scores play an important role in the evaluation of computational tools in medical image analysis. These scores evaluate the quality of various tasks, such as image registration and segmentation, by measuring the similarity between two binary label maps. Commonly these measurements blend two aspects ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2216281

    authors: Konukoglu E,Glocker B,Ye DH,Criminisi A,Pohl KM

    更新日期:2012-12-01 00:00:00

  • Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images.

    abstract::A fully automated approach to segmentation of the left and right cardiac ventricles from magnetic resonance (MR) images is reported. A novel multistage hybrid appearance model methodology is presented in which a hybrid active shape model/active appearance model (AAM) stage helps avoid local minima of the matching func...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.925294

    authors: Mitchell SC,Lelieveldt BP,van der Geest RJ,Bosch HG,Reiber JH,Sonka M

    更新日期:2001-05-01 00:00:00

  • Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

    abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2917026

    authors: Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

    更新日期:2019-12-01 00:00:00

  • Wound status evaluation using color image processing.

    abstract::An accurate diagnosis of burns and pressure ulcers in the early stages can be made by computerized image processing. This study describes a critical assessment of potential methodologies for noninvasive wound evaluation using a color imaging system. We also developed a method for quantifying histological readings and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.552057

    authors: Hansen GL,Sparrow EM,Kokate JY,Leland KJ,Iaizzo PA

    更新日期:1997-02-01 00:00:00

  • MITT: Medical Image Tracking Toolbox.

    abstract::Over the years, medical image tracking has gained considerable attention from both medical and research communities due to its widespread utility in a multitude of clinical applications, from functional assessment during diagnosis and therapy planning to structure tracking or image fusion during image-guided intervent...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2840820

    authors: Queiros S,Morais P,Barbosa D,Fonseca JC,Vilaca JL,D'Hooge J

    更新日期:2018-11-01 00:00:00

  • Pubic arch detection in transrectal ultrasound guided prostate cancer therapy.

    abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736032

    authors: Pathak SD,Grimm PD,Chalana V,Kim Y

    更新日期:1998-10-01 00:00:00

  • Association Between Changes in Mammographic Image Features and Risk for Near-Term Breast Cancer Development.

    abstract::The purpose of this study is to develop and test a new computerized model for predicting near-term breast cancer risk based on quantitative assessment of bilateral mammographic image feature variations in a series of negative full-field digital mammography (FFDM) images. The retrospective dataset included series of fo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2527619

    authors: Tan M,Zheng B,Leader JK,Gur D

    更新日期:2016-07-01 00:00:00

  • Tracking pylorus in ultrasonic image sequences with edge-based optical flow.

    abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2183884

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen Y

    更新日期:2012-03-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.

    abstract::The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2142188

    authors: Roessl E,Brendel B,Engel KJ,Schlomka JP,Thran A,Proksa R

    更新日期:2011-09-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00

  • Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints.

    abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2225152

    authors: Dufour PA,Ceklic L,Abdillahi H,Schröder S,De Dzanet S,Wolf-Schnurrbusch U,Kowal J

    更新日期:2013-03-01 00:00:00

  • Wavelet analysis for brain-function imaging.

    abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414621

    authors: Carmona RA,Hwang WL,Frostig RD

    更新日期:1995-01-01 00:00:00