Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

Abstract:

:Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-XLCT. In this paper, a 4D temporal-spatial reconstruction method based on principal component analysis (PCA) in the projection space is proposed for dynamic CB-XLCT. First, projections of angles in each 3D frame are compressed to reduce the noises initially. Then a temporal PCA is performed on the projection data to decorrelate the 4D problem into separate 3D problems in the PCA domain. In the PCA domain, the difference between dynamic behaviors of multiple targets can be reflected by the first several principal components which can be further used for fast and improved reconstruction by a restarted Tikhonov regularization method. At last, by discarding the principal components mainly reflecting noise, the concentration series of targets are recovered from the first few reconstruction results with a mask as the constraint. The numerical simulation and phantom experiment demonstrate that the proposed method can resolve multiple targets and recover the dynamic distributions with high computation efficiency. The proposed method provides new feasibility for imaging dynamic bio-distributions of probes in vivo.

journal_name

IEEE Trans Med Imaging

authors

Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

doi

10.1109/TMI.2019.2917026

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

2891-2902

issue

12

eissn

0278-0062

issn

1558-254X

journal_volume

38

pub_type

杂志文章
  • MITT: Medical Image Tracking Toolbox.

    abstract::Over the years, medical image tracking has gained considerable attention from both medical and research communities due to its widespread utility in a multitude of clinical applications, from functional assessment during diagnosis and therapy planning to structure tracking or image fusion during image-guided intervent...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2840820

    authors: Queiros S,Morais P,Barbosa D,Fonseca JC,Vilaca JL,D'Hooge J

    更新日期:2018-11-01 00:00:00

  • A proof of the spherical homeomorphism conjecture for surfaces.

    abstract::The human cerebral cortex is topologically equivalent to a sphere when it is viewed as closed at the brain stem. Due to noise and/or resolution issues, magnetic resonance imaging may see "handles" that need to be eliminated to reflect the true spherical topology. Shattuck and Leahy present an algorithm to correct such...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/TMI.2002.806590

    authors: Abrams L,Fishkind DE,Priebe CE

    更新日期:2002-12-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Dynamic Atlas-Based Segmentation and Quantification of Neuromelanin-Rich Brainstem Structures in Parkinson Disease.

    abstract::We present a dynamic atlas composed of neuromelanin-enhanced magnetic resonance brain images of 40 healthy subjects. The performance of this atlas is evaluated on the fully automated segmentation of two paired neuromelanin-rich brainstem healthy structures: the substantia nigra pars compacta and the locus coeruleus. W...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2872852

    authors: Ariz M,Abad RC,Castellanos G,Martinez M,Munoz-Barrutia A,Fernandez-Seara MA,Pastor P,Pastor MA,Ortiz-de-Solorzano C

    更新日期:2019-03-01 00:00:00

  • An estimator for functional data with application to MRI.

    abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.906423

    authors: Godtliebsen F,Chu CK,Sørbye SH,Torheim G

    更新日期:2001-01-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • Framework for Photon Counting Quantitative Material Decomposition.

    abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2914370

    authors: Juntunen MAK,Inkinen SI,Ketola JH,Kotiaho A,Kauppinen M,Winkler A,Nieminen MT

    更新日期:2020-01-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • Multiobjective genetic optimization of diagnostic classifiers with implications for generating receiver operating characteristic curves.

    abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.796281

    authors: Kupinski MA,Anastasio MA

    更新日期:1999-08-01 00:00:00

  • DetexNet: Accurately Diagnosing Frequent and Challenging Pediatric Malignant Tumors.

    abstract::The most frequent extracranial solid tumors of childhood, named peripheral neuroblastic tumors (pNTs), are very challenging to diagnose due to their diversified categories and varying forms. Auxiliary diagnosis methods of such pediatric malignant cancers are highly needed to provide pathologists assistance and reduce ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3027547

    authors: Liu Y,Yin M,Sun S

    更新日期:2021-01-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • Reconstruction and quantification of the carotid artery bifurcation from 3-D ultrasound images.

    abstract::Three-dimensional (3-D) ultrasound is a relatively new technique, which is well suited to imaging superficial blood vessels, and potentially provides a useful, noninvasive method for generating anatomically realistic 3-D models of the peripheral vasculature. Such models are essential for accurate simulation of blood f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/tmi.2004.825601

    authors: Barratt DC,Ariff BB,Humphries KN,Thom SA,Hughes AD

    更新日期:2004-05-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography.

    abstract::This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Fel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.876147

    authors: Schäfer D,Borgert J,Rasche V,Grass M

    更新日期:2006-07-01 00:00:00

  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • Multislice radio-frequency current density imaging.

    abstract::Radio-frequency current density imaging (RF-CDI) is an imaging technique that noninvasively measures current density distribution at the Larmor frequency utilizing magnetic resonance imaging (MRI). Previously implemented RF-CDI techniques were only able to image a single slice transverse to the static magnetic field B...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2012161

    authors: Wang D,DeMonte TP,Ma W,Joy ML,Nachman AI

    更新日期:2009-07-01 00:00:00

  • Estimation and detection of myocardial tags in MR image without user-defined myocardial contours.

    abstract::Magnetic resonance (MR) tagging has been shown to be a useful technique for noninvasively measuring the deformation of an in vivo heart. An important step in analyzing tagged images is the identification of tag lines in each image of a cine sequence. Most existing tag identification algorithms require user defined myo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.768842

    authors: Denney TS Jr

    更新日期:1999-04-01 00:00:00

  • Reconstruction from Sparsely Sampled Data by ART with Interpolated Rays.

    abstract::After a brief discussion of the algebraic reconstruction techniques (ART), we introduce the attenuation problem in positron emission tomography (PET). We anticipate that a generalization of ART, the so-called cyclic subgradient projection (CSP) method, may be useful for solving this problem. This, however, has not bee...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1982.4307567

    authors: Kouris K,Tuy H,Lent A,Herman GT,Lewitt RM

    更新日期:1982-01-01 00:00:00

  • MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): application to fetal, neonatal, and adult brain studies.

    abstract::Motion degrades magnetic resonance (MR) images and prevents acquisition of self-consistent and high-quality volume images. A novel methodology, Snapshot magnetic resonance imaging (MRI) with Volume Reconstruction (SVR) has been developed for imaging moving subjects at high resolution and high signal-to-noise ratio (SN...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895456

    authors: Jiang S,Xue H,Glover A,Rutherford M,Rueckert D,Hajnal JV

    更新日期:2007-07-01 00:00:00

  • Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

    abstract::In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kais...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97598

    authors: Jackson JI,Meyer CH,Nishimura DG,Macovski A

    更新日期:1991-01-01 00:00:00

  • Accelerated Parameter Mapping of Multiple-Echo Gradient-Echo Data Using Model-Based Iterative Reconstruction.

    abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2771504

    authors: Zimmermann M,Abbas Z,Dzieciol K,Shah NJ

    更新日期:2018-02-01 00:00:00

  • MRF-based deformable registration and ventilation estimation of lung CT.

    abstract::Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2246577

    authors: Heinrich MP,Jenkinson M,Brady M,Schnabel JA

    更新日期:2013-07-01 00:00:00

  • Quantitative echocardiographic image texture: normal contraction-related variability.

    abstract::Myocardial tissue characterization using ultrasound is a growing area of investigation which attempts to evaluate the structure of the myocardium by analysis of ultrasound signals. Our laboratory has been exploring the use of texture analysis for the determination of myocardial tissue properties from two-dimensional e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307721

    authors: Collins SM,Skorton DJ,Prasad NV,Olshansky B,Bean JA

    更新日期:1985-01-01 00:00:00

  • Mixture model analysis of DNA microarray images.

    abstract::In this paper, we propose a new methodology for analysis of microarray images. First, a new gridding algorithm is proposed for determining the individual spots and their borders. Then, a Gaussian mixture model (GMM) approach is presented for the analysis of the individual spot images. The main advantages of the propos...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2005.848358

    authors: Blekas K,Galatsanos NP,Likas A,Lagaris IE

    更新日期:2005-07-01 00:00:00

  • Characteristic quantities of microvascular structures in CLSM volume datasets.

    abstract::A method for fully automated morphological and topological quantification of microvascular structures in confocal laser scanning microscopy (CLSM) volume datasets is presented. Several characteristic morphological and topological quantities are calculated in a series of image-processing steps and can be used to compar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900379

    authors: Winter K,Metz LH,Kuska JP,Frerich B

    更新日期:2007-08-01 00:00:00

  • A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

    abstract::A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.668698

    authors: Sled JG,Zijdenbos AP,Evans AC

    更新日期:1998-02-01 00:00:00

  • In situ characterization of the degradation of PLGA microspheres in hyaluronic acid hydrogels by optical coherence tomography.

    abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.927356

    authors: Patterson J,Stayton PS,Li X

    更新日期:2009-01-01 00:00:00

  • Fully automated attenuation measurement and motion correction in FLIP image sequences.

    abstract::Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171497

    authors: van de Giessen M,van der Laan A,Hendriks EA,Vidorreta M,Reiber JH,Jost CR,Tanke HJ,Lelieveldt BP

    更新日期:2012-02-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00