Abstract:
:A fully automated approach to segmentation of the left and right cardiac ventricles from magnetic resonance (MR) images is reported. A novel multistage hybrid appearance model methodology is presented in which a hybrid active shape model/active appearance model (AAM) stage helps avoid local minima of the matching function. This yields an overall more favorable matching result. An automated initialization method is introduced making the approach fully automated. Our method was trained in a set of 102 MR images and tested in a separate set of 60 images. In all testing cases, the matching resulted in a visually plausible and accurate mapping of the model to the image data. Average signed border positioning errors did not exceed 0.3 mm in any of the three determined contours-left-ventricular (LV) epicardium, LV and right-ventricular (RV) endocardium. The area measurements derived from the three contours correlated well with the independent standard (r = 0.96, 0.96, 0.90), with slopes and intercepts of the regression lines close to one and zero, respectively. Testing the reproducibility of the method demonstrated an unbiased performance with small range of error as assessed via Bland-Altman statistic. In direct border positioning error comparison, the multistage method significantly outperformed the conventional AAM (p < 0.001). The developed method promises to facilitate fully automated quantitative analysis of LV and RV morphology and function in clinical setting.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Mitchell SC,Lelieveldt BP,van der Geest RJ,Bosch HG,Reiber JH,Sonka Mdoi
10.1109/42.925294subject
Has Abstractpub_date
2001-05-01 00:00:00pages
415-23issue
5eissn
0278-0062issn
1558-254Xjournal_volume
20pub_type
杂志文章abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2448556
更新日期:2015-12-01 00:00:00
abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.20362
更新日期:1989-01-01 00:00:00
abstract::Coronary artery disease is a major cause of death in women. Breast arterial calcifications (BACs), detected inmammograms, can be useful riskmarkers associated with the disease. We investigate the feasibility of automated and accurate detection ofBACsinmammograms for risk assessment of coronary artery disease. We devel...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2655486
更新日期:2017-05-01 00:00:00
abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3035253
更新日期:2020-11-02 00:00:00
abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.906423
更新日期:2001-01-01 00:00:00
abstract::In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2974844
更新日期:2020-09-01 00:00:00
abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.896789
更新日期:2000-11-01 00:00:00
abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.14520
更新日期:1988-01-01 00:00:00
abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2135374
更新日期:2011-10-01 00:00:00
abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2007.901984
更新日期:2007-12-01 00:00:00
abstract::A two-stage adaptive vector quantization scheme for radiographic image sequence coding is introduced. Each frame in the sequence is first decomposed into a set of vectors, corresponding to nonoverlapping spatially contiguous block of pixels. A codebook is generated using a training set of vectors drawn from the sequen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.3938
更新日期:1988-01-01 00:00:00
abstract::In this paper, we present a two-stage algorithm for mammogram registration, the geometrical alignment of mammogram sequences. The rationale behind this paper stems from the intrinsic difficulties in comparing mammogram sequences. Mammogram comparison is a valuable tool in national breast screening programs as well as ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.848374
更新日期:2005-06-01 00:00:00
abstract::The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.952731
更新日期:2001-09-01 00:00:00
abstract::This paper presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be in...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.809057
更新日期:2003-04-01 00:00:00
abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2597270
更新日期:2017-01-01 00:00:00
abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.746636
更新日期:1998-12-01 00:00:00
abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.938237
更新日期:2001-08-01 00:00:00
abstract::The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) al...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.538946
更新日期:1996-01-01 00:00:00
abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2771504
更新日期:2018-02-01 00:00:00
abstract::The Newton-Raphson (N-R) with two different regularization methods: the Levenberg-Marquardt (N-R-LM) and the Hachtel's Augmented Matrix (N-R-HAM), were used to reconstruct images of conductivity changes in a cylindrical medium by Induced Current Electrical Impedance Tomography (ic-EIT). Experimental data were obtained...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.491419
更新日期:1996-01-01 00:00:00
abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141650
更新日期:1992-01-01 00:00:00
abstract::We investigate using dual time-point PET data to perform Patlak modeling. This approach can be used for whole body dynamic PET studies in which we compute voxel-wise estimates of Patlak parameters using two frames of data for each bed position. Our approach directly uses list-mode arrival times for each event to estim...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2298868
更新日期:2014-04-01 00:00:00
abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2008959
更新日期:2009-07-01 00:00:00
abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2914370
更新日期:2020-01-01 00:00:00
abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.883453
更新日期:2006-11-01 00:00:00
abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.819293
更新日期:2003-11-01 00:00:00
abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.836876
更新日期:2005-01-01 00:00:00
abstract::Diffuse Optical Tomography commonly neglects or assumes as insignificant the presence of optically clear regions in biological tissues, estimating their contribution as a small perturbation to light transport. The inaccuracy introduced by this practice is examined in detail in the context of a complete, based on reali...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2646518
更新日期:2017-05-01 00:00:00
abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307763
更新日期:1986-01-01 00:00:00
abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.895476
更新日期:2007-05-01 00:00:00