Reducing the effects of scattered photons in X-ray projection imaging.

Abstract:

:An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-frequency content are utilized.

journal_name

IEEE Trans Med Imaging

authors

Fahimi H,Macovski A

doi

10.1109/42.20362

subject

Has Abstract

pub_date

1989-01-01 00:00:00

pages

56-63

issue

1

eissn

0278-0062

issn

1558-254X

journal_volume

8

pub_type

杂志文章
  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Unified bundling and registration of brain white matter fibers.

    abstract::Magnetic resonance diffusion tensor imaging is being widely used to reconstruct brain white matter fiber tracts. To characterize structural properties of the tracts, reconstructed fibers are often grouped into bundles that correspond to coherent anatomic structures. For further group analysis of fiber bundles, it is d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016337

    authors: Xu Q,Anderson AW,Gore JC,Ding Z

    更新日期:2009-09-01 00:00:00

  • A method for modeling noise in medical images.

    abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.832656

    authors: Gravel P,Beaudoin G,De Guise JA

    更新日期:2004-10-01 00:00:00

  • Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

    abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2040624

    authors: Angelone LM,Ahveninen J,Belliveau JW,Bonmassar G

    更新日期:2010-04-01 00:00:00

  • Imaging the distribution of magnetic nanoparticles with ultrasound.

    abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895476

    authors: Norton SJ,Vo-Dinh T

    更新日期:2007-05-01 00:00:00

  • Multi-dimensional tumor detection in automated whole breast ultrasound using topographic watershed.

    abstract::Automated whole breast ultrasound (ABUS) is becoming a popular screening modality for whole breast examination. Compared to conventional handheld ultrasound, ABUS achieves operator-independent and is feasible for mass screening. However, reviewing hundreds of slices in an ABUS image volume is time-consuming. A compute...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2315206

    authors: Lo CM,Chen RT,Chang YC,Yang YW,Hung MJ,Huang CS,Chang RF

    更新日期:2014-07-01 00:00:00

  • Lumen segmentation and motion estimation in B-mode and contrast-enhanced ultrasound images of the carotid artery in patients with atherosclerotic plaque.

    abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2372784

    authors: Carvalho DD,Akkus Z,van den Oord SC,Schinkel AF,van der Steen AF,Niessen WJ,Bosch JG,Klein S

    更新日期:2015-04-01 00:00:00

  • Image guided personalization of reaction-diffusion type tumor growth models using modified anisotropic eikonal equations.

    abstract::Reaction-diffusion based tumor growth models have been widely used in the literature for modeling the growth of brain gliomas. Lately, recent models have started integrating medical images in their formulation. Including different tissue types, geometry of the brain and the directions of white matter fiber tracts impr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2026413

    authors: Konukoglu E,Clatz O,Menze BH,Stieltjes B,Weber MA,Mandonnet E,Delingette H,Ayache N

    更新日期:2010-01-01 00:00:00

  • Corrections to "Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity".

    abstract::In the above paper [1], there are typos in Algorithm 1 table. The correct version of Algorithm 1 is given below. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1109/TMI.2018.2849798

    authors: Gong K,Cheng-Liao J,Wang G,Chen KT,Catana C,Qi J

    更新日期:2018-08-01 00:00:00

  • Super Wide-Field Photoacoustic Microscopy of Animals and Humans In Vivo.

    abstract::Acoustic-resolution photoacoustic micro-scopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (~1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biolog...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2938518

    authors: Baik JW,Kim JY,Cho S,Choi S,Kim J,Kim C

    更新日期:2020-04-01 00:00:00

  • Optimizing rod window width in positron emission tomography.

    abstract::A technique determines the optimal window width for orbiting rod transmission studies in positron emission tomography (PET). Windowing reduces noise in orbiting rod transmission studies. Lines-of-response (LOR) which intersect the rods generate primarily true coincidence events. LOR which pass far from the rods genera...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.387708

    authors: Jones WF,Digby WM,Luk WK,Casey ME,Byars LG

    更新日期:1995-01-01 00:00:00

  • A "twisting and bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images.

    abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918326

    authors: Nanayakkara ND,Chiu B,Samani A,Spence JD,Samarabandu J,Fenster A

    更新日期:2008-10-01 00:00:00

  • A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.

    abstract::This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898271

    authors: Lin Y,Schmidtlein CR,Li Q,Li S,Xu Y

    更新日期:2019-09-01 00:00:00

  • Novel EIS postprocessing algorithm for breast cancer diagnosis.

    abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.800605

    authors: Glickman YA,Filo O,Nachaliel U,Lenington S,Amin-Spector S,Ginor R

    更新日期:2002-06-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • A Tensor B-Spline Approach for Solving the Diffusion PDE With Application to Optical Diffusion Tomography.

    abstract::Optical Diffusion Tomography (ODT) is a modern non-invasive medical imaging modality which requires mathematical modelling of near-infrared light propagation in tissue. Solving the ODT forward problem equation accurately and efficiently is crucial. Typically, the forward problem is represented by a Diffusion PDE and i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2641500

    authors: Shulga D,Morozov O,Hunziker P

    更新日期:2017-04-01 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Quantitative echocardiographic image texture: normal contraction-related variability.

    abstract::Myocardial tissue characterization using ultrasound is a growing area of investigation which attempts to evaluate the structure of the myocardium by analysis of ultrasound signals. Our laboratory has been exploring the use of texture analysis for the determination of myocardial tissue properties from two-dimensional e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307721

    authors: Collins SM,Skorton DJ,Prasad NV,Olshansky B,Bean JA

    更新日期:1985-01-01 00:00:00

  • Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis.

    abstract::The quantitative analysis of magnetic resonance imaging (MRI) data has become increasingly important in both research and clinical studies aiming at human brain development, function, and pathology. Inevitably, the role of quantitative image analysis in the evaluation of drug therapy will increase, driven in part by r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806283

    authors: Zijdenbos AP,Forghani R,Evans AC

    更新日期:2002-10-01 00:00:00

  • Augmented Likelihood Image Reconstruction.

    abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2459764

    authors: Stille M,Kleine M,Hägele J,Barkhausen J,Buzug TM

    更新日期:2016-01-01 00:00:00

  • Medusa: a scalable MR console using USB.

    abstract::Magnetic resonance imaging (MRI) pulse sequence consoles typically employ closed proprietary hardware, software, and interfaces, making difficult any adaptation for innovative experimental technology. Yet MRI systems research is trending to higher channel count receivers, transmitters, gradient/shims, and unique inter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2169681

    authors: Stang PP,Conolly SM,Santos JM,Pauly JM,Scott GC

    更新日期:2012-02-01 00:00:00

  • Video-Rate Ring-Array Ultrasound and Photoacoustic Tomography.

    abstract::Ultrasonography and photoacoustic tomography provide complementary contrasts in preclinical studies, disease diagnoses, and imaging-guided interventional procedures. Here, we present a video-rate (20 Hz) dual-modality ultrasound and photoacoustic tomographic platform that has a high resolution, rich contrasts, deep pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3017815

    authors: Zhang Y,Wang L

    更新日期:2020-12-01 00:00:00

  • Simultaneous Estimation of Corneal Topography, Pachymetry, and Curvature.

    abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2836304

    authors: Nasrin F,Iyer RV,Mathews SM

    更新日期:2018-11-01 00:00:00

  • Frequency-domain optical tomographic imaging of arthritic finger joints.

    abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2135374

    authors: Hielscher AH,Kim HK,Montejo LD,Blaschke S,Netz UJ,Zwaka PA,Illing G,Muller GA,Beuthan J

    更新日期:2011-10-01 00:00:00

  • Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications.

    abstract::Mobile C-arm is an essential tool in everyday trauma and orthopedics surgery. Minimally invasive solutions, based on X-ray imaging and coregistered external navigation created a lot of interest within the surgical community and started to replace the traditional open surgery for many procedures. These solutions usuall...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2021947

    authors: Navab N,Heining SM,Traub J

    更新日期:2010-07-01 00:00:00

  • A high resolution PET for animal studies.

    abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.192694

    authors: Watanabe M,Uchida H,Okada H,Shimizu K,Satoh N,Yoshikawa E,Ohmura T,Yamashita T,Tanaka E

    更新日期:1992-01-01 00:00:00

  • Stratified Decision Forests for Accurate Anatomical Landmark Localization in Cardiac Images.

    abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2597270

    authors: Oktay O,Bai W,Guerrero R,Rajchl M,de Marvao A,O'Regan DP,Cook SA,Heinrich MP,Glocker B,Rueckert D

    更新日期:2017-01-01 00:00:00

  • Robust parameter estimation of intensity distributions for brain magnetic resonance images.

    abstract::This paper presents two new methods for robust parameter estimation of mixtures in the context of magnetic resonance (MR) data segmentation. The head is constituted of different types of tissue that can be modeled by a finite mixture of multivariate Gaussian distributions. Our goal is to estimate accurately the statis...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.700730

    authors: Schroeter P,Vesin JM,Langenberger T,Meuli R

    更新日期:1998-04-01 00:00:00