Frequency-domain optical tomographic imaging of arthritic finger joints.

Abstract:

:We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificities of 0.85 and higher can be achieved in detecting RA. This is accomplished by deriving multiple optical parameters from the optical tomographic images and combining them for the statistical analysis. Parameters derived from the scattering coefficient perform slightly better than absorption derived parameters. Furthermore we found that data obtained at 600 MHz leads to better classification results than data obtained at 0 or 300 MHz.

journal_name

IEEE Trans Med Imaging

authors

Hielscher AH,Kim HK,Montejo LD,Blaschke S,Netz UJ,Zwaka PA,Illing G,Muller GA,Beuthan J

doi

10.1109/TMI.2011.2135374

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

1725-36

issue

10

eissn

0278-0062

issn

1558-254X

journal_volume

30

pub_type

杂志文章
  • Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

    abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2203316

    authors: Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

    更新日期:2012-08-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00

  • Characteristic quantities of microvascular structures in CLSM volume datasets.

    abstract::A method for fully automated morphological and topological quantification of microvascular structures in confocal laser scanning microscopy (CLSM) volume datasets is presented. Several characteristic morphological and topological quantities are calculated in a series of image-processing steps and can be used to compar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900379

    authors: Winter K,Metz LH,Kuska JP,Frerich B

    更新日期:2007-08-01 00:00:00

  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • Optimizing rod window width in positron emission tomography.

    abstract::A technique determines the optimal window width for orbiting rod transmission studies in positron emission tomography (PET). Windowing reduces noise in orbiting rod transmission studies. Lines-of-response (LOR) which intersect the rods generate primarily true coincidence events. LOR which pass far from the rods genera...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.387708

    authors: Jones WF,Digby WM,Luk WK,Casey ME,Byars LG

    更新日期:1995-01-01 00:00:00

  • A fast iterated conditional modes algorithm for water-fat decomposition in MRI.

    abstract::Decomposition of water and fat in magnetic resonance imaging (MRI) is important for biomedical research and clinical applications. In this paper, we propose a two-phased approach for the three-point water-fat decomposition problem. Our contribution consists of two components: 1) a background-masked Markov random field...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2125980

    authors: Huang F,Narayan S,Wilson D,Johnson D,Zhang GQ

    更新日期:2011-08-01 00:00:00

  • Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints.

    abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2225152

    authors: Dufour PA,Ceklic L,Abdillahi H,Schröder S,De Dzanet S,Wolf-Schnurrbusch U,Kowal J

    更新日期:2013-03-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • Denoising functional MR images: a comparison of wavelet denoising and Gaussian smoothing.

    abstract::We present a general wavelet-based denoising scheme for functional magnetic resonance imaging (fMRI) data and compare it to Gaussian smoothing, the traditional denoising method used in fMRI analysis. One-dimensional WaveLab thresholding routines were adapted to two-dimensional (2-D) images, and applied to 2-D wavelet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824234

    authors: Wink AM,Roerdink JB

    更新日期:2004-03-01 00:00:00

  • Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2473168

    authors: Guan S,Gray HA,Keynejad F,Pandy MG

    更新日期:2016-01-01 00:00:00

  • Deformable Slice-to-Volume Registration for Motion Correction of Fetal Body and Placenta MRI.

    abstract::In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2974844

    authors: Uus A,Zhang T,Jackson LH,Roberts TA,Rutherford MA,Hajnal JV,Deprez M

    更新日期:2020-09-01 00:00:00

  • Image guided personalization of reaction-diffusion type tumor growth models using modified anisotropic eikonal equations.

    abstract::Reaction-diffusion based tumor growth models have been widely used in the literature for modeling the growth of brain gliomas. Lately, recent models have started integrating medical images in their formulation. Including different tissue types, geometry of the brain and the directions of white matter fiber tracts impr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2026413

    authors: Konukoglu E,Clatz O,Menze BH,Stieltjes B,Weber MA,Mandonnet E,Delingette H,Ayache N

    更新日期:2010-01-01 00:00:00

  • Multi-dimensional tumor detection in automated whole breast ultrasound using topographic watershed.

    abstract::Automated whole breast ultrasound (ABUS) is becoming a popular screening modality for whole breast examination. Compared to conventional handheld ultrasound, ABUS achieves operator-independent and is feasible for mass screening. However, reviewing hundreds of slices in an ABUS image volume is time-consuming. A compute...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2315206

    authors: Lo CM,Chen RT,Chang YC,Yang YW,Hung MJ,Huang CS,Chang RF

    更新日期:2014-07-01 00:00:00

  • Robust Unmixing of Dynamic Sequences Using Regions of Interest.

    abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2759661

    authors: Filippi M,Desvignes M,Moisan E

    更新日期:2018-01-01 00:00:00

  • Detecting Cardiovascular Disease from Mammograms With Deep Learning.

    abstract::Coronary artery disease is a major cause of death in women. Breast arterial calcifications (BACs), detected inmammograms, can be useful riskmarkers associated with the disease. We investigate the feasibility of automated and accurate detection ofBACsinmammograms for risk assessment of coronary artery disease. We devel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2655486

    authors: Wang J,Ding H,Bidgoli FA,Zhou B,Iribarren C,Molloi S,Baldi P

    更新日期:2017-05-01 00:00:00

  • Dynamic PET reconstruction using wavelet regularization with adapted basis functions.

    abstract::Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1) -regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.923698

    authors: Verhaeghe J,Van de Ville D,Khalidov I,D'Asseler Y,Lemahieu I,Unser M

    更新日期:2008-01-01 00:00:00

  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Choice of initial conditions in the ML reconstruction of fan-beam transmission with truncated projection data.

    abstract::We investigate the effects of initial conditions in the iterative maximum-likelihood (ML) reconstruction of fan-beam transmission projection data with truncation. In an iterative ML reconstruction, the estimate of the transmission reconstructed image in the previous iteration is multiplied by some factors to obtain th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.611352

    authors: Pan TS,Tsui BM,Byrne CL

    更新日期:1997-08-01 00:00:00

  • Automated Chest X-Ray Screening: Can Lung Region Symmetry Help Detect Pulmonary Abnormalities?

    abstract::Our primary motivator is the need for screening HIV+ populations in resource-constrained regions for exposure to Tuberculosis, using posteroanterior chest radiographs (CXRs). The proposed method is motivated by the observation that radiological examinations routinely conduct bilateral comparisons of the lung field. In...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2775636

    authors: Santosh KC,Antani S

    更新日期:2018-05-01 00:00:00

  • Time delay for arrival of MR contrast agent in collateral-dependent myocardium.

    abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.827969

    authors: Jerosch-Herold M,Hu X,Murthy NS,Seethamraju RT

    更新日期:2004-07-01 00:00:00

  • Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).

    abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171192

    authors: Değirmenci E,Eyüboğlu BM

    更新日期:2012-03-01 00:00:00

  • Clustered components analysis for functional MRI.

    abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819922

    authors: Chen S,Bouman CA,Lowe MJ

    更新日期:2004-01-01 00:00:00

  • A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

    abstract::When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108599

    authors: Noll DC,Meyer CH,Pauly JM,Nishimura DG,Macovski A

    更新日期:1991-01-01 00:00:00

  • Unsupervised Domain Adaptation from Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks.

    abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052972

    authors: Koehler S,Hussain T,Blair Z,Huffaker T,Ritzmann F,Tandon A,Pickardt T,Sarikouch S,Sarikouch S,Latus H,Greil G,Wolf I,Engelhardt S

    更新日期:2021-01-20 00:00:00

  • Reducing the effects of scattered photons in X-ray projection imaging.

    abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.20362

    authors: Fahimi H,Macovski A

    更新日期:1989-01-01 00:00:00

  • Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing.

    abstract::It is known that when the maximum likelihood estimator (MLE) algorithm passes a certain point, it produces images that begin to deteriorate. We propose a quantitative criterion with a simple probabilistic interpretation that allows the user to stop the algorithm just before this effect begins. The MLE algorithm search...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307849

    authors: Veklerov E,Llacer J

    更新日期:1987-01-01 00:00:00

  • Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.

    abstract::Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of unders...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2870714

    authors: Elliott MR,Kim D,Molony DS,Morris L,Samady H,Joshi S,Timmins LH

    更新日期:2019-03-01 00:00:00