Spatio-temporal fMRI analysis using Markov random fields.

Abstract:

:Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of the data. In this paper, we first discuss the widely used methods based on a statistical parameter map (SPM) analysis exposing the different shortcomings of this approach when considering high-resolution data. First, the often used Gaussian filtering results in a blurring effect and in delocalization of the activated area. Secondly, the SPM approach only considers false alarms due to noise but not rejections of activated voxels. We propose to embed the fMRI analysis problem into a Bayesian framework consisting of two steps: i) data restoration and ii) data analysis. We, therefore, propose two Markov random fields (MRF's) to solve these two problems. Results on three protocols (visual, motor and word recognition) are shown for two SPM approaches and compared with the proposed MRF approach.

journal_name

IEEE Trans Med Imaging

authors

Descombes X,Kruggel F,von Cramon DY

doi

10.1109/42.746636

subject

Has Abstract

pub_date

1998-12-01 00:00:00

pages

1028-39

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

17

pub_type

杂志文章
  • Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

    abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015079

    authors: Zeraatkar N,Kalluri KS,Auer B,Konik A,Fromme TJ,Furenlid LR,Kuo PH,King MA

    更新日期:2020-12-01 00:00:00

  • Endoscopic video manifolds for targeted optical biopsy.

    abstract::Gastro-intestinal (GI) endoscopy is a widely used clinical procedure for screening and surveillance of digestive tract diseases ranging from Barrett's Oesophagus to oesophageal cancer. Current surveillance protocol consists of periodic endoscopic examinations performed in 3-4 month intervals including expert's visual ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2174252

    authors: Atasoy S,Mateus D,Meining A,Yang GZ,Navab N

    更新日期:2012-03-01 00:00:00

  • Unsupervised Myocardial Segmentation for Cardiac BOLD.

    abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2726112

    authors: Oksuz I,Mukhopadhyay A,Dharmakumar R,Tsaftaris SA

    更新日期:2017-11-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00

  • Breast tissue density quantification via digitized mammograms.

    abstract::Studies reported in the literature indicate that breast cancer risk is associated with mammographic densities. An objective, repeatable, and a quantitative measure of risk derived from mammographic densities will be of considerable use in recommending alternative screening paradigms and/or preventive measures. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938247

    authors: Saha PK,Udupa JK,Conant EF,Chakraborty DP,Sullivan D

    更新日期:2001-08-01 00:00:00

  • Dynamic Cell Imaging in PET With Optimal Transport Regularization.

    abstract::We propose a novel dynamic image reconstruction method from PET listmode data that could be particularly suited to tracking single or small numbers of cells. In contrast to conventional PET reconstruction our method combines the information from all detected events not only to reconstruct the dynamic evolution of the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953773

    authors: Schmitzer B,Schafers KP,Wirth B

    更新日期:2020-05-01 00:00:00

  • Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.

    abstract::Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of unders...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2870714

    authors: Elliott MR,Kim D,Molony DS,Morris L,Samady H,Joshi S,Timmins LH

    更新日期:2019-03-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Time delay for arrival of MR contrast agent in collateral-dependent myocardium.

    abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.827969

    authors: Jerosch-Herold M,Hu X,Murthy NS,Seethamraju RT

    更新日期:2004-07-01 00:00:00

  • A Signal Acquisition Setup for Ultrashort Echo Time Imaging Operating in Parallel on Unmodified Clinical MRI Scanners Achieving an Acquisition Delay of [Formula: see text].

    abstract::Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultras...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2924057

    authors: Eder M,Horneff A,Paul J,Storm A,Wunderlich A,Hell E,Ulrici J,Anders J,Rasche V

    更新日期:2020-01-01 00:00:00

  • Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).

    abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171192

    authors: Değirmenci E,Eyüboğlu BM

    更新日期:2012-03-01 00:00:00

  • Regularized field map estimation in MRI.

    abstract::In fast magnetic resonance (MR) imaging with long readout times, such as echo-planar imaging (EPI) and spiral scans, it is important to correct for the effects of field inhomogeneity to reduce image distortion and blurring. Such corrections require an accurate field map, a map of the off-resonance frequency at each vo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.923956

    authors: Funai AK,Fessler JA,Yeo DT,Olafsson VT,Noll DC

    更新日期:2008-10-01 00:00:00

  • Parametric estimate of intensity inhomogeneities applied to MRI.

    abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.845174

    authors: Styner M,Brechbühler C,Székely G,Gerig G

    更新日期:2000-03-01 00:00:00

  • Spatio-Temporal Tensor Decomposition of a Polyaffine Motion Model for a Better Analysis of Pathological Left Ventricular Dynamics.

    abstract::Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2405579

    authors: McLeod K,Sermesant M,Beerbaum P,Pennec X

    更新日期:2015-07-01 00:00:00

  • Patlak image estimation from dual time-point list-mode PET data.

    abstract::We investigate using dual time-point PET data to perform Patlak modeling. This approach can be used for whole body dynamic PET studies in which we compute voxel-wise estimates of Patlak parameters using two frames of data for each bed position. Our approach directly uses list-mode arrival times for each event to estim...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2298868

    authors: Zhu W,Li Q,Bai B,Conti PS,Leahy RM

    更新日期:2014-04-01 00:00:00

  • Interactions Between Large-Scale Functional Brain Networks are Captured by Sparse Coupled HMMs.

    abstract::Functional magnetic resonance imaging (fMRI) provides a window on the human brain at work. Spontaneous brain activity measured during resting-state has already provided many insights into brain function. In particular, recent interest in dynamic interactions between brain regions has increased the need for more advanc...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2755369

    authors: Bolton TAW,Tarun A,Sterpenich V,Schwartz S,Van De Ville D

    更新日期:2018-01-01 00:00:00

  • An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

    abstract::Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, tempora...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2960720

    authors: Li Y,Garrett JW,Li K,Strother C,Chen GH

    更新日期:2020-06-01 00:00:00

  • Automatic construction of 3D-ASM intensity models by simulating image acquisition: application to myocardial gated SPECT studies.

    abstract::Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004819

    authors: Tobon-Gomez C,Butakoff C,Aguade S,Sukno F,Moragas G,Frangi AF

    更新日期:2008-11-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Twenty new digital brain phantoms for creation of validation image data bases.

    abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.883453

    authors: Aubert-Broche B,Griffin M,Pike GB,Evans AC,Collins DL

    更新日期:2006-11-01 00:00:00

  • Classification of disease subgroup and correlation with disease severity using magnetic resonance imaging whole-brain histograms: application to magnetization transfer ratios and multiple sclerosis.

    abstract::This paper presents a new approach to characterize subtle diffuse changes in multiple sclerosis (MS) using histograms derived from magnetization transfer ratio (MTR) images. Two major parts dominate our histogram analysis; 1) Classification of MTR histograms into control and MS subgroups; 2) Correlation with current d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.1000256

    authors: Dehmeshki J,Barker GJ,Tofts PS

    更新日期:2002-04-01 00:00:00

  • A novel approach to extract colon lumen from CT images for virtual colonoscopy.

    abstract::An automatic method has been developed for segmentation of abdominal computed tomography (CT) images for virtual colonoscopy obtained after a bowel preparation of a low-residue diet with ingested contrast solutions to enhance the image intensities of residual colonic materials. Removal of the enhanced materials was pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.897814

    authors: Chen D,Liang Z,Wax MR,Li L,Li B,Kaufman AE

    更新日期:2000-12-01 00:00:00

  • Elevation direction deconvolution in three-dimensional ultrasound imaging.

    abstract::One-dimensional (1-D) linear transducer arrays can be used for three-dimensional (3-D) ultrasound image acquisition. However, the relatively low spatial resolution of these arrays in the elevation direction results in blurry 3-D images. Here, the authors introduce an elevation direction deconvolution (EDD) method that...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.500148

    authors: Wang X,Ritchie CJ,Kim Y

    更新日期:1996-01-01 00:00:00

  • Estimation of Strain Elastography from Ultrasound Radio-Frequency Data by Utilizing Analytic Gradient of the Similarity Metric.

    abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2685522

    authors: Omidyeganeh M,Xiao Y,Ahmad MO,Rivaz H

    更新日期:2017-06-01 00:00:00

  • Assessment of perfusion by dynamic contrast-enhanced imaging using a deconvolution approach based on regression and singular value decomposition.

    abstract::The assessment of tissue perfusion by dynamic contrast-enhanced (DCE) imaging involves a deconvolution process. For analysis of DCE imaging data, we implemented a regression approach to select appropriate regularization parameters for deconvolution using the standard and generalized singular value decomposition method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.837355

    authors: Koh TS,Wu XY,Cheong LH,Lim CC

    更新日期:2004-12-01 00:00:00

  • Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

    abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232251

    authors: Caorsi S,Gragnani GL,Pastorino M

    更新日期:1993-01-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Keypoint Transfer for Fast Whole-Body Segmentation.

    abstract::We introduce an approach for image segmentation based on sparse correspondences between keypoints in testing and training images. Keypoints represent automatically identified distinctive image locations, where each keypoint correspondence suggests a transformation between images. We use these correspondences to transf...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2851194

    authors: Wachinger C,Toews M,Langs G,Wells W,Golland P

    更新日期:2020-02-01 00:00:00

  • Compressive Deconvolution in Medical Ultrasound Imaging.

    abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2493241

    authors: Chen Z,Basarab A,Kouamé D