Abstract:
:The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of a diagnosis aid system for resolving potential ambiguities associated with intensity-based feature extractors. On CT images, near-perpendicular cross sections of bronchi normally appear as elliptical rings and this paper presents a novel technique for their recognition. The proposed method, the edge-radius-symmetry (ERS) transform, is based on the analysis of the distribution of edges in local polar coordinates. Pixels are ranked according to local edge (E) strength, radial (R), uniformity and local symmetry (S). A discrete implementation of the technique is provided which reduces the computational cost of the ERS transform by using a geometric approximation of the intensity patterns. The identification of the adjacent pulmonary vessels with template matching then allows for the automated measurement of bronchial dilatation and bronchial wall thickening. Computationally, the method compares favorably with other methods such as the Hough transform. Noise-sensitivity of the technique was evaluated on a set of synthetic images and nine patients under investigation for suspected airways disease. Agreement for the automated scoring of the presence and severity of bronchial abnormalities was demonstrated to be comparable to that of an experienced radiologist (kappa statistics kappa > 0.5 ).
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Chabat F,Hu XP,Hansell DM,Yang GZdoi
10.1109/42.952731subject
Has Abstractpub_date
2001-09-01 00:00:00pages
942-52issue
9eissn
0278-0062issn
1558-254Xjournal_volume
20pub_type
杂志文章abstract::In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2254719
更新日期:2013-06-01 00:00:00
abstract::This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.781017
更新日期:1999-06-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2019957
更新日期:2009-10-01 00:00:00
abstract::We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (F...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2948258
更新日期:2020-05-01 00:00:00
abstract::The accuracy of in vivo dopamine D2 receptor quantification by positron emission tomography (PET) was determined for several models by means of singular-value decomposition, and some of the model assumptions were reviewed. These include steady-state, transient, double injection, and equilibrium approaches. All four mo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.7783
更新日期:1988-01-01 00:00:00
abstract::A method for measuring the spatial concentration of specific categories of vessels in a vascular network consisting of vessels of several diameters, lengths, and orientations is demonstrated. It is shown that a combination of the mathematical morphology operation, opening, with a linear rotating structuring element (R...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.241865
更新日期:1993-01-01 00:00:00
abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2395257
更新日期:2015-06-01 00:00:00
abstract::Repetitive and alternating lower limb movements are a specific component of human gait. Due to technical challenges, the neural mechanisms underlying such movements have not been previously studied with functional magnetic resonance imaging. In this study, we present a novel treadmill device employed to investigate th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2301493
更新日期:2014-05-01 00:00:00
abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.822821
更新日期:2004-02-01 00:00:00
abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2193896
更新日期:2012-08-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2281984
更新日期:2014-02-01 00:00:00
abstract::Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on inte...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.871545
更新日期:2006-04-01 00:00:00
abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2473168
更新日期:2016-01-01 00:00:00
abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307836
更新日期:1987-01-01 00:00:00
abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.276141
更新日期:1994-01-01 00:00:00
abstract::Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this wo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2529500
更新日期:2016-08-01 00:00:00
abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2252361
更新日期:2013-08-01 00:00:00
abstract::Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/tmi.2002.800606
更新日期:2002-06-01 00:00:00
abstract::Image textures in computed tomography colonography (CTC) have great potential for differentiating non-neoplastic from neoplastic polyps and thus can advance the current CTC detection-only paradigm to a new level with diagnostic capability. However, image textures are frequently compromised, particularly in low-dose CT...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2518958
更新日期:2016-06-01 00:00:00
abstract::The multi-channel nature of digital histopathological images presents an opportunity to exploit the correlated color channel information for better image modeling. Inspired by recent work in sparsity for single channel image classification, we propose a new simultaneous sparsity model for multi-channel histopathologic...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2306173
更新日期:2014-05-01 00:00:00
abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192694
更新日期:1992-01-01 00:00:00
abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2958943
更新日期:2020-06-01 00:00:00
abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2808699
更新日期:2018-08-01 00:00:00
abstract::Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1) -regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.923698
更新日期:2008-01-01 00:00:00
abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2450831
更新日期:2015-12-01 00:00:00
abstract::The study presented in this paper tests the hypothesis that the combination of a global similarity transformation and local free-form deformations can be used for the accurate segmentation of internal structures in MR images of the brain. To quantitatively evaluate our approach, the entire brain, the cerebellum, and t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.811271
更新日期:1999-10-01 00:00:00
abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2288521
更新日期:2014-02-01 00:00:00
abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2759661
更新日期:2018-01-01 00:00:00
abstract::When more than two elemental materials are present in a given object, material quantification may not be robust and accurate when the routine two-material decomposition scheme in current dual energy CT imaging is employed. In this work, we present an innovative scheme to accomplish accurate three-material decompositio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2990347
更新日期:2020-11-01 00:00:00
abstract::While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2699672
更新日期:2017-09-01 00:00:00