A high resolution PET for animal studies.

Abstract:

:In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the system a 7-slice imaging capability. The gantry head tilts up to +/-90 degrees , and is capable of moving up and down by 30 cm. These positioning capabilities allow flexibility and great ease of use in subject positioning. A gantry entrance size of 22 cm in diameter allows studies ranging from rats and mice to primates such as Rhesus and squirrel monkeys. The physical performance of the system has been evaluated.

journal_name

IEEE Trans Med Imaging

authors

Watanabe M,Uchida H,Okada H,Shimizu K,Satoh N,Yoshikawa E,Ohmura T,Yamashita T,Tanaka E

doi

10.1109/42.192694

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

577-80

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

11

pub_type

杂志文章
  • Use of needle track detection to quantify the displacement of stranded seeds following prostate brachytherapy.

    abstract::We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2178254

    authors: Lobo JR,Moradi M,Chng N,Dehghan E,Morris WJ,Fichtinger G,Salcudean SE

    更新日期:2012-03-01 00:00:00

  • Improvement of Chest Region CT Images through Automated Gray-Level Remapping.

    abstract::A software system, CTIP, written in Fortran is discussed which remaps the computerized tomography (CT) image gray level so that both the lung and heart regions are clearly visible with a "natural anatomical appearance." The system is adaptive to image statistics derived from the gray-level histogram of the entire imag...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307736

    authors: Davis G,Wallenslager ST

    更新日期:1986-01-01 00:00:00

  • Monitoring Acute Stroke Progression: Multi-Parametric OCT Imaging of Cortical Perfusion, Flow, and Tissue Scattering in a Mouse Model of Permanent Focal Ischemia.

    abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2895779

    authors: Choi WJ,Li Y,Wang RK

    更新日期:2019-06-01 00:00:00

  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • Automatic Segmentation and Quantification of White and Brown Adipose Tissues from PET/CT Scans.

    abstract::In this paper, we investigate the automatic detection of white and brown adipose tissues using Positron Emission Tomography/Computed Tomography (PET/CT) scans, and develop methods for the quantification of these tissues at the whole-body and body-region levels. We propose a patient-specific automatic adiposity analysi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2636188

    authors: Hussein S,Green A,Watane A,Reiter D,Chen X,Papadakis GZ,Wood B,Cypess A,Osman M,Bagci U

    更新日期:2017-03-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • A Single Scatter Model for X-ray CT Energy Spectrum Estimation and Polychromatic Reconstruction.

    abstract::To improve the quantitative accuracy of linear attenuation coefficients measured by computed tomography (CT), we used a single scatter model to estimate the Compton scatter distribution and then a polychromatic image reconstruction algorithm, namely the iterative maximum-likelihood polychromatic algorithm for CT (IMPA...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395438

    authors: Lee JS,Chen JC

    更新日期:2015-06-01 00:00:00

  • Burn depth analysis using multidimensional scaling applied to psychophysical experiment data.

    abstract::In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2254719

    authors: Acha B,Serrano C,Fondón I,Gómez-Cía T

    更新日期:2013-06-01 00:00:00

  • An improved algorithm for 2-D translational motion artifact correction.

    abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108589

    authors: Medley M,Yan H,Rosenfeld D

    更新日期:1991-01-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Compressive Deconvolution in Medical Ultrasound Imaging.

    abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2493241

    authors: Chen Z,Basarab A,Kouamé D

    更新日期:2016-03-01 00:00:00

  • Probabilistic independent component analysis for functional magnetic resonance imaging.

    abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.822821

    authors: Beckmann CF,Smith SM

    更新日期:2004-02-01 00:00:00

  • Learning Geodesic Active Contours for Embedding Object Global Information in Segmentation CNNs.

    abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022693

    authors: Ma J,He J,Yang X

    更新日期:2021-01-01 00:00:00

  • Ultrasound imaging and identification of microcalcification clusters by correlation of scatter from multiple angles.

    abstract::Various types of malignant and benign breast tumors are associated with clusters of calcifications with grain sizes 0.1 to a few mm spread out over volumes of a few cc. A series of phantoms containing calcium carbonate grains embedded in a gelatin mixture were made and the ultrasound scattering patterns were measured ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307668

    authors: Perez-Mendez V,Wiedenbeck P,Davis P,Tzeng CJ

    更新日期:1984-01-01 00:00:00

  • Digital processing for improvement of ultrasonic abdominal images.

    abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1983.4307617

    authors: Liu CN,Fatemi M,Waag RC

    更新日期:1983-01-01 00:00:00

  • Reconstruction of SPECT images using generalized matrix inverses.

    abstract::Generalized matrix inverses are used to estimate source activity distributions from single photon emission computed tomography (SPECT) projection measurements. Image reconstructions for a numerical simulation and a clinical brain study are examined. The photon flux from the source region and photon detection by the ga...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.141640

    authors: Smith MF,Floyd CR,Jaszczak RJ,Coleman RE

    更新日期:1992-01-01 00:00:00

  • Camera augmented mobile C-arm (CAMC): calibration, accuracy study, and clinical applications.

    abstract::Mobile C-arm is an essential tool in everyday trauma and orthopedics surgery. Minimally invasive solutions, based on X-ray imaging and coregistered external navigation created a lot of interest within the surgical community and started to replace the traditional open surgery for many procedures. These solutions usuall...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2021947

    authors: Navab N,Heining SM,Traub J

    更新日期:2010-07-01 00:00:00

  • Out-of-plane motion compensation in multislice spin-echo MRI.

    abstract::In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414611

    authors: Riek JK,Tekalp AM,Smith WE,Kwok E

    更新日期:1995-01-01 00:00:00

  • Flux-based anisotropic diffusion applied to enhancement of 3-D angiogram.

    abstract::We present a new approach to anisotropic diffusion based on a multidirectional diffusion flux. The diffusion flux is decomposed in an orthogonal basis, effectively enabling enhancement of contours as well as diffusion along the contours. To this end, we have selected a three-dimensional basis that depicts the directio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.806403

    authors: Krissian K

    更新日期:2002-11-01 00:00:00

  • Automatic construction of 3D-ASM intensity models by simulating image acquisition: application to myocardial gated SPECT studies.

    abstract::Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004819

    authors: Tobon-Gomez C,Butakoff C,Aguade S,Sukno F,Moragas G,Frangi AF

    更新日期:2008-11-01 00:00:00

  • Spherical Deformable U-Net: Application to Cortical Surface Parcellation and Development Prediction.

    abstract::Convolutional Neural Networks (CNNs) have achieved overwhelming success in learning-related problems for 2D/3D images in the Euclidean space. However, unlike in the Euclidean space, the shapes of many structures in medical imaging have an inherent spherical topology in a manifold space, e.g., the convoluted brain cort...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3050072

    authors: Zhao F,Wu Z,Wang L,Lin W,Gilmore JH,Xia S,Shen D,Li G

    更新日期:2021-01-08 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Estimation and detection of myocardial tags in MR image without user-defined myocardial contours.

    abstract::Magnetic resonance (MR) tagging has been shown to be a useful technique for noninvasively measuring the deformation of an in vivo heart. An important step in analyzing tagged images is the identification of tag lines in each image of a cine sequence. Most existing tag identification algorithms require user defined myo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.768842

    authors: Denney TS Jr

    更新日期:1999-04-01 00:00:00

  • Fully automated attenuation measurement and motion correction in FLIP image sequences.

    abstract::Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171497

    authors: van de Giessen M,van der Laan A,Hendriks EA,Vidorreta M,Reiber JH,Jost CR,Tanke HJ,Lelieveldt BP

    更新日期:2012-02-01 00:00:00

  • Digital flashing tomosynthesis: a promising technique for angiocardiographic screening.

    abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232261

    authors: Stiel GM,Stiel LG,Klotz E,Nienaber CA

    更新日期:1993-01-01 00:00:00

  • Automated segmentation of multiple sclerosis lesions by model outlier detection.

    abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938237

    authors: Van Leemput K,Maes F,Vandermeulen D,Colchester A,Suetens P

    更新日期:2001-08-01 00:00:00

  • A system for real-time XMR guided cardiovascular intervention.

    abstract::The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.856731

    authors: Rhode KS,Sermesant M,Brogan D,Hegde S,Hipwell J,Lambiase P,Rosenthal E,Bucknall C,Qureshi SA,Gill JS,Razavi R,Hill DL

    更新日期:2005-11-01 00:00:00

  • Restoration of signal polarity in a set of inversion recovery NMR images.

    abstract::A method is described which enables unambiguous retrieval of sign information in a set of magnetic resonance magnitude images of the inversion recovery type. The proposed method starts from the observation that the inversion recovery curve S is a monotonically increasing function of the inversion time TI, and comes do...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307681

    authors: Bakker CG,De Graaf CN,Van Dijk P

    更新日期:1984-01-01 00:00:00

  • NIR-II/NIR-I Fluorescence Molecular Tomography of Heterogeneous Mice Based on Gaussian Weighted Neighborhood Fused Lasso Method.

    abstract::Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satisfactory reconstruct...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2964853

    authors: Cai M,Zhang Z,Shi X,Hu Z,Tian J

    更新日期:2020-06-01 00:00:00

  • Hybrid feature-based diffeomorphic registration for tumor tracking in 2-D liver ultrasound images.

    abstract::Real-time ultrasound image acquisition is a pivotal resource in the medical community, in spite of its limited image quality. This poses challenges to image registration methods, particularly to those driven by intensity values. We address these difficulties in a novel diffeomorphic registration technique for tumor tr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2262055

    authors: Cifor A,Risser L,Chung D,Anderson EM,Schnabel JA

    更新日期:2013-09-01 00:00:00