Abstract:
:In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the system a 7-slice imaging capability. The gantry head tilts up to +/-90 degrees , and is capable of moving up and down by 30 cm. These positioning capabilities allow flexibility and great ease of use in subject positioning. A gantry entrance size of 22 cm in diameter allows studies ranging from rats and mice to primates such as Rhesus and squirrel monkeys. The physical performance of the system has been evaluated.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Watanabe M,Uchida H,Okada H,Shimizu K,Satoh N,Yoshikawa E,Ohmura T,Yamashita T,Tanaka Edoi
10.1109/42.192694subject
Has Abstractpub_date
1992-01-01 00:00:00pages
577-80issue
4eissn
0278-0062issn
1558-254Xjournal_volume
11pub_type
杂志文章abstract::We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2178254
更新日期:2012-03-01 00:00:00
abstract::A software system, CTIP, written in Fortran is discussed which remaps the computerized tomography (CT) image gray level so that both the lung and heart regions are clearly visible with a "natural anatomical appearance." The system is adaptive to image statistics derived from the gray-level histogram of the entire imag...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307736
更新日期:1986-01-01 00:00:00
abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2895779
更新日期:2019-06-01 00:00:00
abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2008959
更新日期:2009-07-01 00:00:00
abstract::In this paper, we investigate the automatic detection of white and brown adipose tissues using Positron Emission Tomography/Computed Tomography (PET/CT) scans, and develop methods for the quantification of these tissues at the whole-body and body-region levels. We propose a patient-specific automatic adiposity analysi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2636188
更新日期:2017-03-01 00:00:00
abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2212203
更新日期:2012-10-01 00:00:00
abstract::To improve the quantitative accuracy of linear attenuation coefficients measured by computed tomography (CT), we used a single scatter model to estimate the Compton scatter distribution and then a polychromatic image reconstruction algorithm, namely the iterative maximum-likelihood polychromatic algorithm for CT (IMPA...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2395438
更新日期:2015-06-01 00:00:00
abstract::In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2254719
更新日期:2013-06-01 00:00:00
abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.108589
更新日期:1991-01-01 00:00:00
abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2332571
更新日期:2014-11-01 00:00:00
abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2493241
更新日期:2016-03-01 00:00:00
abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.822821
更新日期:2004-02-01 00:00:00
abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3022693
更新日期:2021-01-01 00:00:00
abstract::Various types of malignant and benign breast tumors are associated with clusters of calcifications with grain sizes 0.1 to a few mm spread out over volumes of a few cc. A series of phantoms containing calcium carbonate grains embedded in a gelatin mixture were made and the ultrasound scattering patterns were measured ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1984.4307668
更新日期:1984-01-01 00:00:00
abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1983.4307617
更新日期:1983-01-01 00:00:00
abstract::Generalized matrix inverses are used to estimate source activity distributions from single photon emission computed tomography (SPECT) projection measurements. Image reconstructions for a numerical simulation and a clinical brain study are examined. The photon flux from the source region and photon detection by the ga...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141640
更新日期:1992-01-01 00:00:00
abstract::Mobile C-arm is an essential tool in everyday trauma and orthopedics surgery. Minimally invasive solutions, based on X-ray imaging and coregistered external navigation created a lot of interest within the surgical community and started to replace the traditional open surgery for many procedures. These solutions usuall...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2021947
更新日期:2010-07-01 00:00:00
abstract::In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.414611
更新日期:1995-01-01 00:00:00
abstract::We present a new approach to anisotropic diffusion based on a multidirectional diffusion flux. The diffusion flux is decomposed in an orthogonal basis, effectively enabling enhancement of contours as well as diffusion along the contours. To this end, we have selected a three-dimensional basis that depicts the directio...
journal_title:IEEE transactions on medical imaging
pub_type: 信件
doi:10.1109/TMI.2002.806403
更新日期:2002-11-01 00:00:00
abstract::Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques ar...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2004819
更新日期:2008-11-01 00:00:00
abstract::Convolutional Neural Networks (CNNs) have achieved overwhelming success in learning-related problems for 2D/3D images in the Euclidean space. However, unlike in the Euclidean space, the shapes of many structures in medical imaging have an inherent spherical topology in a manifold space, e.g., the convoluted brain cort...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2021.3050072
更新日期:2021-01-08 00:00:00
abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2406575
更新日期:2015-07-01 00:00:00
abstract::Magnetic resonance (MR) tagging has been shown to be a useful technique for noninvasively measuring the deformation of an in vivo heart. An important step in analyzing tagged images is the identification of tag lines in each image of a cine sequence. Most existing tag identification algorithms require user defined myo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.768842
更新日期:1999-04-01 00:00:00
abstract::Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2171497
更新日期:2012-02-01 00:00:00
abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.232261
更新日期:1993-01-01 00:00:00
abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.938237
更新日期:2001-08-01 00:00:00
abstract::The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sl...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.856731
更新日期:2005-11-01 00:00:00
abstract::A method is described which enables unambiguous retrieval of sign information in a set of magnetic resonance magnitude images of the inversion recovery type. The proposed method starts from the observation that the inversion recovery curve S is a monotonically increasing function of the inversion time TI, and comes do...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1984.4307681
更新日期:1984-01-01 00:00:00
abstract::Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satisfactory reconstruct...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2964853
更新日期:2020-06-01 00:00:00
abstract::Real-time ultrasound image acquisition is a pivotal resource in the medical community, in spite of its limited image quality. This poses challenges to image registration methods, particularly to those driven by intensity values. We address these difficulties in a novel diffeomorphic registration technique for tumor tr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2262055
更新日期:2013-09-01 00:00:00