Out-of-plane motion compensation in multislice spin-echo MRI.

Abstract:

:In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet been completely analyzed due to its more complex nature. Out-of-plane motion introduces blurring along the slice-selection direction in addition to motion artifacts. Here, the authors present a model to represent the effect of out-of-plane motion on multislice MR data. The inversion of this model not only results in the correction of the artifacts due to out-of-plane motion, but also reduces blurring in the slice-selection direction, yielding higher resolution images. Because of the shift-varying nature of the authors' model, they propose to use a nonlinear postprocessing method, projection onto convex sets (POCS), for its inversion, provided that the motion kernel and the slice-selection profile are known. The proposed method has been tested on simulated data and then applied to actual MR data to demonstrate the feasibility of the technique in real imaging situations.

journal_name

IEEE Trans Med Imaging

authors

Riek JK,Tekalp AM,Smith WE,Kwok E

doi

10.1109/42.414611

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

464-70

issue

3

eissn

0278-0062

issn

1558-254X

journal_volume

14

pub_type

杂志文章
  • A Single Scatter Model for X-ray CT Energy Spectrum Estimation and Polychromatic Reconstruction.

    abstract::To improve the quantitative accuracy of linear attenuation coefficients measured by computed tomography (CT), we used a single scatter model to estimate the Compton scatter distribution and then a polychromatic image reconstruction algorithm, namely the iterative maximum-likelihood polychromatic algorithm for CT (IMPA...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395438

    authors: Lee JS,Chen JC

    更新日期:2015-06-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • The detection and quantification of retinopathy using digital angiograms.

    abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363106

    authors: Zhou L,Rzeszotarski MS,Singerman LJ,Chokreff JM

    更新日期:1994-01-01 00:00:00

  • Automatic segmentation of scaling in 2-D psoriasis skin images.

    abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2236349

    authors: Lu J,Kazmierczak E,Manton JH,Sinclair R

    更新日期:2013-04-01 00:00:00

  • Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

    abstract::We propose a new method for the joint design of k-space trajectory and RF pulse in 3D small-tip tailored excitation. Designing time-varying RF and gradient waveforms for a desired 3D target excitation pattern in MRI poses a non-linear, non-convex, constrained optimization problem with relatively large problem size tha...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2478880

    authors: Hao S,Fessler JA,Noll DC,Nielsen JF

    更新日期:2016-02-01 00:00:00

  • Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation.

    abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899910

    authors: Wang S,Yu L,Yang X,Fu CW,Heng PA

    更新日期:2019-11-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Bayesian approach for a robust speed-of-sound reconstruction using pulse-echo ultrasound.

    abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3029286

    authors: Stahli PS,Frenz M,Jaeger M

    更新日期:2020-10-07 00:00:00

  • Patlak image estimation from dual time-point list-mode PET data.

    abstract::We investigate using dual time-point PET data to perform Patlak modeling. This approach can be used for whole body dynamic PET studies in which we compute voxel-wise estimates of Patlak parameters using two frames of data for each bed position. Our approach directly uses list-mode arrival times for each event to estim...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2298868

    authors: Zhu W,Li Q,Bai B,Conti PS,Leahy RM

    更新日期:2014-04-01 00:00:00

  • Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

    abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2547988

    authors: Jiaen Liu,Van de Moortele PF,Xiaotong Zhang,Yicun Wang,Bin He

    更新日期:2016-09-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function.

    abstract::Ultrasonic imaging is the noninvasive clinical imaging modality of choice for diagnosing heart disease. At present, two-dimensional ultrasonic grayscale images provide a relatively cheap, fast, bedside method to study the morphology of the heart. Several methods have been proposed to assess myocardial function. These ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.804440

    authors: D'hooge J,Bijnens B,Thoen J,Van de Werf F,Sutherland GR,Suetens P

    更新日期:2002-09-01 00:00:00

  • The effect of image distortion on 3-D reconstruction of coronary bypass grafts from angiographic views.

    abstract::Three-dimensional (3-D) reconstructions of coronary bypass grafts performed from X-ray angiographic images may become increasingly important for the investigation of damaging mechanical stresses imposed to these vessels by the cyclic movement of the heart. Contrary to what we had experienced with coronary arteries, ap...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.875203

    authors: Dorsaz PA,Dorsaz L,Doriot PA

    更新日期:2000-07-01 00:00:00

  • Estimating the Accuracy Level Among Individual Detections in Clustered Microcalcifications.

    abstract::Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2654799

    authors: Sainz de Cea MV,Nishikawa RM,Yang Y

    更新日期:2017-05-01 00:00:00

  • Gray-scale skeletonization of small vessels in magnetic resonance angiography.

    abstract::Interpretation of magnetic resonance angiography (MRA) is problematic due to complexities of vascular shape and to artifacts such as the partial volume effect. We present new methods to assist in the interpretation of MRA. These include methods for detection of vessel paths and for determination of branching patterns ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,评审

    doi:10.1109/42.870662

    authors: Yim PJ,Choyke PL,Summers RM

    更新日期:2000-06-01 00:00:00

  • Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

    abstract::When more than two elemental materials are present in a given object, material quantification may not be robust and accurate when the routine two-material decomposition scheme in current dual energy CT imaging is employed. In this work, we present an innovative scheme to accomplish accurate three-material decompositio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990347

    authors: Ji X,Zhang R,Li K,Chen GH

    更新日期:2020-11-01 00:00:00

  • The n-PI-method for helical cone-beam CT.

    abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.887834

    authors: Proksa R,Köhler T,Grass M,Timmer J

    更新日期:2000-09-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data.

    abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870257

    authors: Obi T,Matej S,Lewitt RM,Herman GT

    更新日期:2000-05-01 00:00:00

  • Spherical harmonics microwave algorithm for shape and location reconstruction of breast cancer tumor.

    abstract::A reconstruction algorithm to simultaneously estimate the shape and location of three-dimensional breast cancer tumor is presented and its utility is analyzed. The approach is based on a spherical harmonic decomposition to capture the shape of the tumor. We combine a gradient descent optimization method with a direct ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.881377

    authors: El-Shenawee M,Miller EL

    更新日期:2006-10-01 00:00:00

  • High-Permittivity Pad Design for Dielectric Shimming in Magnetic Resonance Imaging Using Projection-Based Model Reduction and a Nonlinear Optimization Scheme.

    abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791179

    authors: van Gemert JHF,Brink WM,Webb AG,Remis RF

    更新日期:2018-04-01 00:00:00

  • Segmentation of the optic disc, macula and vascular arch in fundus photographs.

    abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.885336

    authors: Niemeijer M,Abràmoff MD,van Ginneken B

    更新日期:2007-01-01 00:00:00

  • Unsupervised Myocardial Segmentation for Cardiac BOLD.

    abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2726112

    authors: Oksuz I,Mukhopadhyay A,Dharmakumar R,Tsaftaris SA

    更新日期:2017-11-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Hybrid feature-based diffeomorphic registration for tumor tracking in 2-D liver ultrasound images.

    abstract::Real-time ultrasound image acquisition is a pivotal resource in the medical community, in spite of its limited image quality. This poses challenges to image registration methods, particularly to those driven by intensity values. We address these difficulties in a novel diffeomorphic registration technique for tumor tr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2262055

    authors: Cifor A,Risser L,Chung D,Anderson EM,Schnabel JA

    更新日期:2013-09-01 00:00:00

  • Comments on "A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions".

    abstract::In this paper, discrepancies and reference inaccuracies in the paper (Grana et al., 2003) are pointed out. Specifically, it is demonstrated that the definitions of "lesion gradient" and "skin lesion gradient," widely used in a number of medical papers on computer analysis of pigmented skin lesions, are unambiguous, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/tmi.2006.884205

    authors: Burroni M,Alparone L,Argenti F

    更新日期:2006-12-01 00:00:00

  • Progressive coding and transmission of digital diagnostic pictures.

    abstract::In radiology, as a result of the increased utilization of digital imaging modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI), over a third of the images produced in a typical radiology department are currently in digital form, and this percentage is steadily increasing. Image compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307750

    authors: Elnahas SE,Tzou KH,Cox JR,Hill RL,Jost R

    更新日期:1986-01-01 00:00:00

  • Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.

    abstract::Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2343936

    authors: Neumann D,Grbic S,John M,Navab N,Hornegger J,Ionasec R

    更新日期:2015-01-01 00:00:00

  • Low-field 3-DFT MRI: conceptual, analytical, and experimental aspects.

    abstract::Three-dimensional Fourier transform (3-DFT) magnetic resonance imaging (MRI) offers advantages in terms of signal-to-noise (S/N) per unit of time for the case where a large number of slices is desired. This advantage is enhanced when the relaxation time, T(1 ), is short. Because time limitations in 3-DFT imaging force...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97588

    authors: Kramer DM,Kaufman L,Rothschild P,Hale J,Wummer J,Hake KK

    更新日期:1991-01-01 00:00:00