Abstract:
:A method is described which enables unambiguous retrieval of sign information in a set of magnetic resonance magnitude images of the inversion recovery type. The proposed method starts from the observation that the inversion recovery curve S is a monotonically increasing function of the inversion time TI, and comes down to finding the zero-crossing time TI0 of this curve for each pixel within the image. Absolute Value(S)and S are then related by S(TI) = -Absolute Value(S(TI)) for TI =/< TI(0) and S(TI) = + Absolute Value(S(TI)) for TI =/> TI0. The method, which does not require additional knowledge with respect to any of the NMR parameters involved, is shown to be effective when at least four inversion recovery images with different inversion times of a particular object slice are available. The efficacy of sign retrieval is demonstrated by imaging experiments on phantoms and human subjects. The validity of the polarity restoration method is established by viewing its results against the results of conventional methods, i.e., NMR spectroscopy.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Bakker CG,De Graaf CN,Van Dijk Pdoi
10.1109/TMI.1984.4307681subject
Has Abstractpub_date
1984-01-01 00:00:00pages
197-202issue
4eissn
0278-0062issn
1558-254Xjournal_volume
3pub_type
杂志文章abstract::This paper describes a multimodality framework for computer-aided myocardial viability assessment based on neuro-fuzzy techniques. The proposed approach distinguishes two main levels: the modality-independent inference level and the modality-dependent application level. This two-level distinction releases the hard con...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.974925
更新日期:2001-12-01 00:00:00
abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.414621
更新日期:1995-01-01 00:00:00
abstract::Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator v...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.746626
更新日期:1998-12-01 00:00:00
abstract::Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displa...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2405579
更新日期:2015-07-01 00:00:00
abstract::We propose a novel dynamic image reconstruction method from PET listmode data that could be particularly suited to tracking single or small numbers of cells. In contrast to conventional PET reconstruction our method combines the information from all detected events not only to reconstruct the dynamic evolution of the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2953773
更新日期:2020-05-01 00:00:00
abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.24861
更新日期:1989-01-01 00:00:00
abstract::An algorithm is developed that detects well-localized, unfragmented, thin edges in medical images based on optimization of edge configurations using a genetic algorithm (GA). Several enhancements were added to improve the performance of the algorithm over a traditional GA. The edge map is split into connected subregio...
journal_title:IEEE transactions on medical imaging
pub_type: 信件
doi:10.1109/42.712136
更新日期:1998-06-01 00:00:00
abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2061862
更新日期:2011-01-01 00:00:00
abstract::Intrinsic or data-driven respiratory and cardiac motion detection often track the center-of-mass (COM) change in PET data to derive a motion gating signal. The effectiveness of this method depends on the contrast of the moving target to the relatively stationary background. The stationary background leads to a reduced...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2423976
更新日期:2015-10-01 00:00:00
abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2459764
更新日期:2016-01-01 00:00:00
abstract::Robust and fast 3D tracking of deformable objects, such as heart, is a challenging task because of the relatively low image contrast and speed requirement. Many existing 2D algorithms might not be directly applied on the 3D tracking problem. The 3D tracking performance is limited due to dramatically increased data siz...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2158440
更新日期:2011-11-01 00:00:00
abstract::While medical imaging typically provides massive amounts of data, the extraction of relevant information for predictive diagnosis remains a difficult challenge. Functional magnetic resonance imaging (fMRI) data, that provide an indirect measure of task-related or spontaneous neuronal activity, are classically analyzed...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2113378
更新日期:2011-07-01 00:00:00
abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870257
更新日期:2000-05-01 00:00:00
abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2029097
更新日期:2010-01-01 00:00:00
abstract::A method is introduced to compensate for missing projection data that can result from gas between detectors or from malfunctioning detectors. This method uses constraints in the Fourier domain to estimate the missing data, thus completing the data set so that the filtered backprojection algorithm can be used to recons...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.3925
更新日期:1988-01-01 00:00:00
abstract::Three-dimensional Fourier transform (3-DFT) magnetic resonance imaging (MRI) offers advantages in terms of signal-to-noise (S/N) per unit of time for the case where a large number of slices is desired. This advantage is enhanced when the relaxation time, T(1 ), is short. Because time limitations in 3-DFT imaging force...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97588
更新日期:1991-01-01 00:00:00
abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791179
更新日期:2018-04-01 00:00:00
abstract::We propose a novel adaptive approach based on the Reproducing Kernel Particle Method (RKPM) to extract the cortical surfaces of the brain from three-dimensional (3-D) magnetic resonance images (MRIs). To formulate the discrete equations of the deformable model, a flexible particle shape function is employed in the Gal...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.873614
更新日期:2006-06-01 00:00:00
abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2002.806405
更新日期:2002-12-01 00:00:00
abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2895779
更新日期:2019-06-01 00:00:00
abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3036032
更新日期:2020-11-05 00:00:00
abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.880677
更新日期:2006-10-01 00:00:00
abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899328
更新日期:2019-10-01 00:00:00
abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1983.4307617
更新日期:1983-01-01 00:00:00
abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2461533
更新日期:2016-01-01 00:00:00
abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2004.831221
更新日期:2004-08-01 00:00:00
abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2578939
更新日期:2016-12-01 00:00:00
abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2034515
更新日期:2010-03-01 00:00:00
abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2473168
更新日期:2016-01-01 00:00:00
abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2495246
更新日期:2016-03-01 00:00:00