Abstract:
:A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic methods in conjunction with advanced machine learning techniques. Specifically, a kernel-based metric named maximum mean discrepancy (MMD), a technique for learning from imbalanced data based on random undersampling, and supervised learning were investigated with response-monitoring data from LABC patients. The CAT system was tested on 56 patients using statistical significance tests and leave-one-subject-out classification techniques. Textural features using state-of-the-art local binary patterns (LBP), and gray-scale intensity features were extracted from the spectral parametric maps in the proposed CAT system. The system indicated significant differences in changes between the responding and non-responding patient populations as well as high accuracy, sensitivity, and specificity in discriminating between the two patient groups early after the start of treatment, i.e., on weeks 1 and 4 of several months of treatment. The proposed CAT system achieved an accuracy of 85%, 87%, and 90% on weeks 1, 4 and 8, respectively. The sensitivity and specificity of developed CAT system for the same times was 85%, 95%, 90% and 85%, 85%, 91%, respectively. The proposed CAT system thus establishes a noninvasive framework for monitoring cancer treatment response in tumors using clinical ultrasound imaging in conjunction with machine learning techniques. Such a framework can potentially facilitate the detection of refractory responses in patients to treatment early on during a course of therapy to enable possibly switching to more efficacious treatments.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJdoi
10.1109/TMI.2015.2495246subject
Has Abstractpub_date
2016-03-01 00:00:00pages
778-90issue
3eissn
0278-0062issn
1558-254Xjournal_volume
35pub_type
杂志文章abstract::Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on inte...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.871545
更新日期:2006-04-01 00:00:00
abstract::A software system, CTIP, written in Fortran is discussed which remaps the computerized tomography (CT) image gray level so that both the lung and heart regions are clearly visible with a "natural anatomical appearance." The system is adaptive to image statistics derived from the gray-level histogram of the entire imag...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307736
更新日期:1986-01-01 00:00:00
abstract::Image textures in computed tomography colonography (CTC) have great potential for differentiating non-neoplastic from neoplastic polyps and thus can advance the current CTC detection-only paradigm to a new level with diagnostic capability. However, image textures are frequently compromised, particularly in low-dose CT...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2518958
更新日期:2016-06-01 00:00:00
abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2337321
更新日期:2014-12-01 00:00:00
abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126914
更新日期:1992-01-01 00:00:00
abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.887834
更新日期:2000-09-01 00:00:00
abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.79481
更新日期:1991-01-01 00:00:00
abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2003.816959
更新日期:2003-09-01 00:00:00
abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870257
更新日期:2000-05-01 00:00:00
abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2040624
更新日期:2010-04-01 00:00:00
abstract::A fully automated, unsupervised lobe segmentation algorithm is presented based on a probabilistic segmentation of the fissures and the simultaneous construction of a populationmodel of the fissures. A two-class probabilistic segmentation segments the lung into candidate fissure voxels and the surrounding parenchyma. T...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2688377
更新日期:2017-08-01 00:00:00
abstract::The point spread function (PSF) of a ring PET tomograph is known to be spatially variant and difficult to obtain because it must be reconstructed from projections. A mathematical model was developed to simulate the data acquisition from a point source and to reconstruct the PSF, taking into account weighting functions...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.158942
更新日期:1992-01-01 00:00:00
abstract::Spectral computed tomography (CT) provides information on material characterization and quantification because of its ability to separate different basis materials. Dual-energy (DE) CT provides two sets of measurements at two different source energies. In principle, two materials can be accurately decomposed from DECT...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2320284
更新日期:2014-08-01 00:00:00
abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.843179
更新日期:2005-03-01 00:00:00
abstract::Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of unders...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2870714
更新日期:2019-03-01 00:00:00
abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.108589
更新日期:1991-01-01 00:00:00
abstract::Coronary heart disease is a common cause of death despite being preventable. To treat the underlying plaque deposits in the arterial walls, intravascular optical coherence tomography can be used by experts to detect and characterize the lesions. In clinical routine, hundreds of images are acquired for each patient, wh...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2865659
更新日期:2019-02-01 00:00:00
abstract::Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.921482
更新日期:2001-04-01 00:00:00
abstract::Acoustic-resolution photoacoustic micro-scopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (~1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biolog...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2938518
更新日期:2020-04-01 00:00:00
abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.812251
更新日期:2003-05-01 00:00:00
abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307836
更新日期:1987-01-01 00:00:00
abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.803104
更新日期:2002-08-01 00:00:00
abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791488
更新日期:2018-07-01 00:00:00
abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2236349
更新日期:2013-04-01 00:00:00
abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.796281
更新日期:1999-08-01 00:00:00
abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2461533
更新日期:2016-01-01 00:00:00
abstract::Image acquisition techniques often suffer from low signal-to-noise ratio (SNR) and/or contrast-to-noise ratio (CNR). Although many acquisition techniques are available to minimize these, post acquisition filtering is a major off-line image processing technique commonly used to improve the SNR and CNR. A major drawback...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.963817
更新日期:2001-11-01 00:00:00
abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.927356
更新日期:2009-01-01 00:00:00
abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2322815
更新日期:2014-09-01 00:00:00
abstract::A minimalist numerical model of white matter is presented, the objective of which is to help provide a biological basis for improved diffusion tensor imaging (DTI) analysis. Water diffuses, relaxes, and exchanges in three compartments-intracellular, extracellular, and myelin sheath. Exchange between compartments is de...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.906787
更新日期:2007-11-01 00:00:00