A proposed taxonomy for nailfold capillaries based on their morphology.

Abstract:

:Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous work. We propose a taxonomy for nailfold capillaries that cover six descriptive classes: cuticulis, open, tortuous, crossed, bushy, and bizarre. The first three are parametric in that they may be distinguished by the ratio of capillary length to width and by the curvature of the capillary limbs. The last three are characterized by their topology; a crossed capillary has a closed area that is not connected to the image background. Bushy and bizarre capillaries have atypical shapes that are characterized by the convex hull of their skeleton. These descriptive classes may be modified according to anomalies in width and length. The second aim is to automate the classification of capillaries by encapsulating the taxonomy in an algorithm; our computer program rivals the most experienced clinicians in classifying capillaries consistently with an overall agreement of 85% with the clinicians' majority view. This was particularly valuable in classifying borderline shapes objectively and consistently.

journal_name

IEEE Trans Med Imaging

authors

Jones BF,Oral M,Morris CW,Ring EF

doi

10.1109/42.921482

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

333-41

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

20

pub_type

杂志文章
  • Novel EIS postprocessing algorithm for breast cancer diagnosis.

    abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.800605

    authors: Glickman YA,Filo O,Nachaliel U,Lenington S,Amin-Spector S,Ginor R

    更新日期:2002-06-01 00:00:00

  • Framework for Photon Counting Quantitative Material Decomposition.

    abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2914370

    authors: Juntunen MAK,Inkinen SI,Ketola JH,Kotiaho A,Kauppinen M,Winkler A,Nieminen MT

    更新日期:2020-01-01 00:00:00

  • Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.

    abstract::The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2142188

    authors: Roessl E,Brendel B,Engel KJ,Schlomka JP,Thran A,Proksa R

    更新日期:2011-09-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].

    abstract::An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.75611

    authors: Pauly J,Le Roux P,Nishimura D,Macovski A

    更新日期:1991-01-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • Magnetic resonance angiography.

    abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307763

    authors: Nishimura DG,Macovski A,Pauly JM

    更新日期:1986-01-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator.

    abstract::While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699672

    authors: Tremblay-Darveau C,Bar-Zion A,Williams R,Sheeran PS,Milot L,Loupas T,Adam D,Bruce M,Burns PN

    更新日期:2017-09-01 00:00:00

  • Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions.

    abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2559538

    authors: Haegele J,Panagiotopoulos N,Cremers S,Rahmer J,Franke J,Duschka RL,Vaalma S,Heidenreich M,Borgert J,Borm P,Barkhausen J,Vogt FM

    更新日期:2016-10-01 00:00:00

  • Objective Detection of Eloquent Axonal Pathways to Minimize Postoperative Deficits in Pediatric Epilepsy Surgery using Diffusion Tractography and Convolutional Neural Networks.

    abstract::Convolutional neural networks (CNNs) have recently been used in biomedical imaging applications with great success. In this paper, we investigated the classi?cation performance of CNN models on diffusion weighted imaging (DWI) streamlines de?ned by functional MRI (fMRI) and electrical stimulation mapping (ESM). To lea...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2902073

    authors: Xu H,Dong M,Lee MH,OrHara N,Asano E,Jeong JW

    更新日期:2019-02-27 00:00:00

  • Low-Rank Atlas Image Analyses in the Presence of Pathologies.

    abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2448556

    authors: Liu X,Niethammer M,Kwitt R,Singh N,McCormick M,Aylward S

    更新日期:2015-12-01 00:00:00

  • Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

    abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2593900

    authors: Allan G,Nouranian S,Tsang T,Seitel A,Mirian M,Jue J,Hawley D,Fleming S,Gin K,Swift J,Rohling R,Abolmaesumi P

    更新日期:2017-01-01 00:00:00

  • Spatiotemporal forward solution of the EEG and MEG using network modeling.

    abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.1009385

    authors: Jirsa VK,Jantzen KJ,Fuchs A,Kelso JA

    更新日期:2002-05-01 00:00:00

  • Choice of initial conditions in the ML reconstruction of fan-beam transmission with truncated projection data.

    abstract::We investigate the effects of initial conditions in the iterative maximum-likelihood (ML) reconstruction of fan-beam transmission projection data with truncation. In an iterative ML reconstruction, the estimate of the transmission reconstructed image in the previous iteration is multiplied by some factors to obtain th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.611352

    authors: Pan TS,Tsui BM,Byrne CL

    更新日期:1997-08-01 00:00:00

  • Spatially adaptive mixture modeling for analysis of FMRI time series.

    abstract::Within-subject analysis in fMRI essentially addresses two problems, the detection of brain regions eliciting evoked activity and the estimation of the underlying dynamics. In Makni et aL, 2005 and Makni et aL, 2008, a detection-estimation framework has been proposed to tackle these problems jointly, since they are con...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2042064

    authors: Vincent T,Risser L,Ciuciu P

    更新日期:2010-04-01 00:00:00

  • Nonrigid motion modeling of the liver from 3-D undersampled self-gated golden-radial phase encoded MRI.

    abstract::Magnetic resonance imaging (MRI) has been commonly used for guiding and planning image guided interventions since it provides excellent soft tissue visualization of anatomy and allows motion modeling to predict the position of target tissues during the procedure. However, MRI-based motion modeling remains challenging ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2181997

    authors: Buerger C,Clough RE,King AP,Schaeffter T,Prieto C

    更新日期:2012-03-01 00:00:00

  • Three-dimensional PET emission scan registration and transmission scan synthesis.

    abstract::The duration of a positron emission tomography (PET) imaging scan can be reduced if the transmission scan of one patient which is used for emission correction can be synthesized by using the reference transmission scan of another patient. In this paper, we propose a new intersubjects PET emission scan registration met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640744

    authors: Huang CL,Chang WT,Wu LC,Wang JK

    更新日期:1997-10-01 00:00:00

  • Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    abstract::Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699973

    authors: Wang X,Seetohul V,Chen R,Zhang Z,Qian M,Shi Z,Yang G,Mu P,Wang C,Huang Z,Zhou Q,Zheng H,Cochran S,Qiu W

    更新日期:2017-09-01 00:00:00

  • Prediction based collaborative trackers (PCT): a robust and accurate approach toward 3D medical object tracking.

    abstract::Robust and fast 3D tracking of deformable objects, such as heart, is a challenging task because of the relatively low image contrast and speed requirement. Many existing 2D algorithms might not be directly applied on the 3D tracking problem. The 3D tracking performance is limited due to dramatically increased data siz...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2158440

    authors: Yang L,Georgescu B,Zheng Y,Wang Y,Meer P,Comaniciu D

    更新日期:2011-11-01 00:00:00

  • Classification of malignant and benign masses based on hybrid ART2LDA approach.

    abstract::A new type of classifier combining an unsupervised and a supervised model was designed and applied to classification of malignant and benign masses on mammograms. The unsupervised model was based on an adaptive resonance theory (ART2) network which clustered the masses into a number of separate classes. The classes we...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.819327

    authors: Hadjiiski L,Sahiner B,Chan HP,Petrick N,Helvie M

    更新日期:1999-12-01 00:00:00

  • ERS transform for the automated detection of bronchial abnormalities on CT of the lungs.

    abstract::The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.952731

    authors: Chabat F,Hu XP,Hansell DM,Yang GZ

    更新日期:2001-09-01 00:00:00

  • Tracking multiple particles in fluorescence time-lapse microscopy images via probabilistic data association.

    abstract::Tracking subcellular structures as well as viral structures displayed as 'particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2359541

    authors: Godinez WJ,Rohr K

    更新日期:2015-02-01 00:00:00

  • Self-Supervised Ultrasound to MRI Fetal Brain Image Synthesis.

    abstract::Fetal brain magnetic resonance imaging (MRI) offers exquisite images of the developing brain but is not suitable for second-trimester anomaly screening, for which ultrasound (US) is employed. Although expert sonographers are adept at reading US images, MR images which closely resemble anatomical images are much easier...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3018560

    authors: Jiao J,Namburete AIL,Papageorghiou AT,Noble JA

    更新日期:2020-12-01 00:00:00

  • Shortest path refinement for motion estimation from tagged MR images.

    abstract::Magnetic resonance tagging makes it possible to measure the motion of tissues such as muscles in the heart and tongue. The harmonic phase (HARP) method largely automates the process of tracking points within tagged MR images, permitting many motion properties to be computed. However, HARP tracking can yield erroneous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2045509

    authors: Liu X,Prince JL

    更新日期:2010-08-01 00:00:00

  • A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

    abstract::The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) al...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538946

    authors: Browne J,de Pierro AB

    更新日期:1996-01-01 00:00:00

  • DetexNet: Accurately Diagnosing Frequent and Challenging Pediatric Malignant Tumors.

    abstract::The most frequent extracranial solid tumors of childhood, named peripheral neuroblastic tumors (pNTs), are very challenging to diagnose due to their diversified categories and varying forms. Auxiliary diagnosis methods of such pediatric malignant cancers are highly needed to provide pathologists assistance and reduce ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3027547

    authors: Liu Y,Yin M,Sun S

    更新日期:2021-01-01 00:00:00

  • Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.

    abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2880092

    authors: Alawad M,Wang L

    更新日期:2019-05-01 00:00:00

  • A geometric method for automatic extraction of sulcal fundi.

    abstract::Sulcal fundi are 3-D curves that lie in the depths of the cerebral cortex and, in addition to their intrinsic value in brain research, are often used as landmarks for downstream computations in brain imaging. In this paper, we present a geometric algorithm that automatically extracts the sulcal fundi from magnetic res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.886810

    authors: Kao CY,Hofer M,Sapiro G,Stem J,Rehm K,Rottenberg DA

    更新日期:2007-04-01 00:00:00