Spatially adaptive mixture modeling for analysis of FMRI time series.

Abstract:

:Within-subject analysis in fMRI essentially addresses two problems, the detection of brain regions eliciting evoked activity and the estimation of the underlying dynamics. In Makni et aL, 2005 and Makni et aL, 2008, a detection-estimation framework has been proposed to tackle these problems jointly, since they are connected to one another. In the Bayesian formalism, detection is achieved by modeling activating and nonactivating voxels through independent mixture models (IMM) within each region while hemodynamic response estimation is performed at a regional scale in a nonparametric way. Instead of IMMs, in this paper we take advantage of spatial mixture models (SMM) for their nonlinear spatial regularizing properties. The proposed method is unsupervised and spatially adaptive in the sense that the amount of spatial correlation is automatically tuned from the data and this setting automatically varies across brain regions. In addition, the level of regularization is specific to each experimental condition since both the signal-to-noise ratio and the activation pattern may vary across stimulus types in a given brain region. These aspects require the precise estimation of multiple partition functions of underlying Ising fields. This is addressed efficiently using first path sampling for a small subset of fields and then using a recently developed fast extrapolation technique for the large remaining set. Simulation results emphasize that detection relying on supervised SMM outperforms its IMM counterpart and that unsupervised spatial mixture models achieve similar results without any hand-tuning of the correlation parameter. On real datasets, the gain is illustrated in a localizer fMRI experiment: brain activations appear more spatially resolved using SMM in comparison with classical general linear model (GLM)-based approaches, while estimating a specific parcel-based HRF shape. Our approach therefore validates the treatment of unsmoothed fMRI data without fixed GLM definition at the subject level and makes also the classical strategy of spatial Gaussian filtering deprecated.

journal_name

IEEE Trans Med Imaging

authors

Vincent T,Risser L,Ciuciu P

doi

10.1109/TMI.2010.2042064

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

1059-74

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

29

pub_type

杂志文章
  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • Technique for reduction of truncation artifact in chemical shift images.

    abstract::The authors describe a technique to reduce truncation artifacts in chemical shift images taken for in vivo magnetic resonance spectroscopy by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the bound...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97578

    authors: Hu X,Stillman AE

    更新日期:1991-01-01 00:00:00

  • A method for modeling noise in medical images.

    abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.832656

    authors: Gravel P,Beaudoin G,De Guise JA

    更新日期:2004-10-01 00:00:00

  • Ultrasound imaging and identification of microcalcification clusters by correlation of scatter from multiple angles.

    abstract::Various types of malignant and benign breast tumors are associated with clusters of calcifications with grain sizes 0.1 to a few mm spread out over volumes of a few cc. A series of phantoms containing calcium carbonate grains embedded in a gelatin mixture were made and the ultrasound scattering patterns were measured ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307668

    authors: Perez-Mendez V,Wiedenbeck P,Davis P,Tzeng CJ

    更新日期:1984-01-01 00:00:00

  • Border detection on digitized skin tumor images.

    abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.896789

    authors: Zhang Z,Stoecker WV,Moss RH

    更新日期:2000-11-01 00:00:00

  • Parametric estimate of intensity inhomogeneities applied to MRI.

    abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.845174

    authors: Styner M,Brechbühler C,Székely G,Gerig G

    更新日期:2000-03-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • Endoscopic video manifolds for targeted optical biopsy.

    abstract::Gastro-intestinal (GI) endoscopy is a widely used clinical procedure for screening and surveillance of digestive tract diseases ranging from Barrett's Oesophagus to oesophageal cancer. Current surveillance protocol consists of periodic endoscopic examinations performed in 3-4 month intervals including expert's visual ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2174252

    authors: Atasoy S,Mateus D,Meining A,Yang GZ,Navab N

    更新日期:2012-03-01 00:00:00

  • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.

    abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.817785

    authors: Kostis WJ,Reeves AP,Yankelevitz DF,Henschke CI

    更新日期:2003-10-01 00:00:00

  • Multiscale AM-FM methods for diabetic retinopathy lesion detection.

    abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2037146

    authors: Agurto C,Murray V,Barriga E,Murillo S,Pattichis M,Davis H,Russell S,Abramoff M,Soliz P

    更新日期:2010-02-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Splat feature classification with application to retinal hemorrhage detection in fundus images.

    abstract::A novel splat feature classification method is presented with application to retinal hemorrhage detection in fundus images. Reliable detection of retinal hemorrhages is important in the development of automated screening systems which can be translated into practice. Under our supervised approach, retinal color images...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2227119

    authors: Tang L,Niemeijer M,Reinhardt JM,Garvin MK,Abràmoff MD

    更新日期:2013-02-01 00:00:00

  • Exact radon rebinning algorithm for the long object problem in helical cone-beam CT.

    abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870247

    authors: Schaller S,Sauer F,Tam KC,Lauritsch G,Flohr T

    更新日期:2000-05-01 00:00:00

  • A generative model for image segmentation based on label fusion.

    abstract::We propose a nonparametric, probabilistic model for the automatic segmentation of medical images, given a training set of images and corresponding label maps. The resulting inference algorithms rely on pairwise registrations between the test image and individual training images. The training labels are then transferre...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2050897

    authors: Sabuncu MR,Yeo BT,Van Leemput K,Fischl B,Golland P

    更新日期:2010-10-01 00:00:00

  • A backprojection filtering algorithm for a spatially varying focal length collimator.

    abstract::Fan-beam collimators are used in single photon emission computed tomography to improve the sensitivity for imaging of small organs. The disadvantage of fan-beam collimation is the truncation of projection data surrounding the organ of interest or, in those cases of imaging large patients, of the organ itself producing...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.310886

    authors: Zeng GL,Gullberg GT

    更新日期:1994-01-01 00:00:00

  • In vivo impedance imaging with total variation regularization.

    abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2022540

    authors: Borsic A,Graham BM,Adler A,Lionheart WR

    更新日期:2010-01-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • A Predictive Model of Vertebral Trabecular Anisotropy From Ex Vivo Micro-CT.

    abstract::Spine-related disorders are amongst the most frequently encountered problems in clinical medicine. For several applications such as 1) to improve the assessment of the strength of the spine, as well as 2) to optimize the personalization of spinal interventions, image-based biomechanical modeling of the vertebrae is ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2387114

    authors: Lekadir K,Hoogendoorn C,Hazrati-Marangalou J,Taylor Z,Noble C,van Rietbergen B,Frangi AF

    更新日期:2015-08-01 00:00:00

  • Multi-scale tubular structure detection in ultrasound imaging.

    abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2340912

    authors: Hennersperger C,Baust M,Waelkens P,Karamalis A,Ahmadi SA,Navab N

    更新日期:2015-01-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • In Vivo Measurement of Brain Tissue Response After Irradiation: Comparison of T2 Relaxation, Apparent Diffusion Coefficient, and Electrical Conductivity.

    abstract::Radiation therapy (RT) has been widely used as a powerful treatment tool to address cancerous tissues because of its ability to control cell growth. Its ionizing radiation damages the DNA of cancerous tissues, leading to cell death. Medical imaging, however, still has limitations regarding the reliability of its asses...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2913766

    authors: Park JA,Kang KJ,Ko IO,Lee KC,Choi BK,Katoch N,Kim JW,Kim HJ,Kwon OI,Woo EJ

    更新日期:2019-12-01 00:00:00

  • Robust Energy Calibration Technique for Photon Counting Spectral Detectors.

    abstract::This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic X-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time-d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2875932

    authors: Vespucci S,Park CS,Torrico R,Das M

    更新日期:2019-04-01 00:00:00

  • A comprehensive cardiac motion estimation framework using both untagged and 3-D tagged MR images based on nonrigid registration.

    abstract::In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion wi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2188104

    authors: Shi W,Zhuang X,Wang H,Duckett S,Luong DV,Tobon-Gomez C,Tung K,Edwards PJ,Rhode KS,Razavi RS,Ourselin S,Rueckert D

    更新日期:2012-06-01 00:00:00

  • A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is a promising tool in the evaluation of tumor physiology. From rapidly acquired images and a model for contrast agent pharmacokinetics, physiological parameters are derived. One pharmacokinetic model, the tissue homogeneity model, enables estimation of both b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016212

    authors: Garpebring A,Ostlund N,Karlsson M

    更新日期:2009-09-01 00:00:00

  • A geometry-driven optical flow warping for spatial normalization of cortical surfaces.

    abstract::Spatial normalization is frequently used to map data to a standard coordinate system by removing intersubject morphological differences, thereby allowing for group analysis to be carried out. The work presented in this paper is motivated by the need for an automated cortical surface normalization technique that will a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.925080

    authors: Tosun D,Prince JL

    更新日期:2008-12-01 00:00:00

  • Automated characterization of breast lesions imaged with an ultrafast DCE-MR protocol.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2281984

    authors: Platel B,Mus R,Welte T,Karssemeijer N,Mann R

    更新日期:2014-02-01 00:00:00

  • REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

    abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2059709

    authors: Lee J,Labat C,Jain AK,Song DY,Burdette EC,Fichtinger G,Prince JL

    更新日期:2011-01-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00