Abstract:
:The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstruction (REDMAPS) that uses multiple X-ray fluoroscopy images obtained from different poses is proposed. The seed reconstruction problem is formulated as a combinatorial optimization problem, and REDMAPS finds a solution in a clinically acceptable amount of time using dimensionality reduction to create a smaller space of possible solutions. Dimensionality reduction is possible since the optimal solution has approximately zero cost when the poses of the acquired images are known to be within a small error. REDMAPS is also formulated to address the "hidden seed problem" in which seeds overlap on one or more observed images. REDMAPS uses a pruning algorithm to avoid unnecessary computation of cost metrics and the reduced problem is solved using linear programming. REDMAPS was first evaluated and its parameters tuned using simulations. It was then validated using five phantom and 21 patient datasets. REDMAPS was successful in reconstructing the seeds with an overall seed matching rate above 99% and a reconstruction error below 1 mm in less than 5 s.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Lee J,Labat C,Jain AK,Song DY,Burdette EC,Fichtinger G,Prince JLdoi
10.1109/TMI.2010.2059709subject
Has Abstractpub_date
2011-01-01 00:00:00pages
38-51issue
1eissn
0278-0062issn
1558-254Xjournal_volume
30pub_type
杂志文章abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2230018
更新日期:2013-02-01 00:00:00
abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.959302
更新日期:2001-10-01 00:00:00
abstract::Gastro-intestinal (GI) endoscopy is a widely used clinical procedure for screening and surveillance of digestive tract diseases ranging from Barrett's Oesophagus to oesophageal cancer. Current surveillance protocol consists of periodic endoscopic examinations performed in 3-4 month intervals including expert's visual ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2174252
更新日期:2012-03-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is a promising tool in the evaluation of tumor physiology. From rapidly acquired images and a model for contrast agent pharmacokinetics, physiological parameters are derived. One pharmacokinetic model, the tissue homogeneity model, enables estimation of both b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2016212
更新日期:2009-09-01 00:00:00
abstract::In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion wi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2188104
更新日期:2012-06-01 00:00:00
abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2448556
更新日期:2015-12-01 00:00:00
abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2372784
更新日期:2015-04-01 00:00:00
abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2326041
更新日期:2014-10-01 00:00:00
abstract::Hand-bone analysis with image processing techniques using a digital radiograph can be used to assess skeletal age. The analysis consists of two steps: phalangeal and carpal bone analysis. The carpal bone analysis is discussed. First, the carpal bone region of interest (CROI) is defined using a standard thresholding te...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.222665
更新日期:1993-01-01 00:00:00
abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.736056
更新日期:1998-10-01 00:00:00
abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3031913
更新日期:2020-10-19 00:00:00
abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.905106
更新日期:2008-03-01 00:00:00
abstract::The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.363096
更新日期:1994-01-01 00:00:00
abstract::The three-dimensional cardiac electrical imaging (3DCEI) technique was previously developed to estimate the initiation site(s) of cardiac activation and activation sequence from the noninvasively measured body surface potential maps (BSPMs). The aim of this study was to develop and evaluate the capability of 3DCEI in ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2202914
更新日期:2012-09-01 00:00:00
abstract::An automatic method has been developed for segmentation of abdominal computed tomography (CT) images for virtual colonoscopy obtained after a bowel preparation of a low-residue diet with ingested contrast solutions to enhance the image intensities of residual colonic materials. Removal of the enhanced materials was pe...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.897814
更新日期:2000-12-01 00:00:00
abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2037146
更新日期:2010-02-01 00:00:00
abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2029097
更新日期:2010-01-01 00:00:00
abstract::The Bayesian ideal observer provides an absolute upper bound for diagnostic performance of an imaging system and hence should be used for the assessment of image quality whenever possible. However, computation of ideal-observer performance in clinical tasks is difficult since the probability density functions of the d...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2008967
更新日期:2009-05-01 00:00:00
abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2806878
更新日期:2018-08-01 00:00:00
abstract::High-resolution X-ray computed tomography (CT) imaging is routinely used for clinical pulmonary applications. Since lung function varies regionally and because pulmonary disease is usually not uniformly distributed in the lungs, it is useful to study the lungs on a lobe-by-lobe basis. Thus, it is important to segment ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.859209
更新日期:2006-01-01 00:00:00
abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3015079
更新日期:2020-12-01 00:00:00
abstract::Advances in the area of digital chest radiography have resulted in the acquisition of high-quality images of the human chest. With these advances, there arises a genuine need for image processing algorithms specific to the chest, in order to fully exploit this digital technology. We have implemented the well-known tec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307791
更新日期:1987-01-01 00:00:00
abstract::A method is introduced to compensate for missing projection data that can result from gas between detectors or from malfunctioning detectors. This method uses constraints in the Fourier domain to estimate the missing data, thus completing the data set so that the filtered backprojection algorithm can be used to recons...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.3925
更新日期:1988-01-01 00:00:00
abstract::A two-stage adaptive vector quantization scheme for radiographic image sequence coding is introduced. Each frame in the sequence is first decomposed into a set of vectors, corresponding to nonoverlapping spatially contiguous block of pixels. A codebook is generated using a training set of vectors drawn from the sequen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.3938
更新日期:1988-01-01 00:00:00
abstract::In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.712126
更新日期:1998-06-01 00:00:00
abstract::The authors describe a technique to reduce truncation artifacts in chemical shift images taken for in vivo magnetic resonance spectroscopy by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the bound...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97578
更新日期:1991-01-01 00:00:00
abstract::Although Blood Oxygenation Level Dependent (BOLD) functional MRI (fMRI) is widely used to examine brain function in adults, the need for general anesthesia limits its practical utility in infants and small children. Functional Near-Infrared Spectroscopy - Diffuse Optical Tomography (fNIRS-DOT) imaging promises to be a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2990823
更新日期:2020-11-01 00:00:00
abstract::An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are dev...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192684
更新日期:1992-01-01 00:00:00
abstract::The purpose of this study is to develop and test a new computerized model for predicting near-term breast cancer risk based on quantitative assessment of bilateral mammographic image feature variations in a series of negative full-field digital mammography (FFDM) images. The retrospective dataset included series of fo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2527619
更新日期:2016-07-01 00:00:00
abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.370412
更新日期:1995-01-01 00:00:00