Abstract:
:The purpose of this study is to develop and test a new computerized model for predicting near-term breast cancer risk based on quantitative assessment of bilateral mammographic image feature variations in a series of negative full-field digital mammography (FFDM) images. The retrospective dataset included series of four sequential FFDM examinations of 335 women. The last examination in each series ("current") and the three most recent "prior" examinations were obtained. All "prior" examinations were interpreted as negative during the original clinical image reading, while in the "current" examinations 159 cancers were detected and pathologically verified and 176 cases remained cancer-free. From each image, we initially computed 158 mammographic density, structural similarity, and texture based image features. The absolute subtraction value between the left and right breasts was selected to represent each feature. We then built three support vector machine (SVM) based risk models, which were trained and tested using a leave-one-case-out based cross-validation method. The actual features used in each SVM model were selected using a nested stepwise regression analysis method. The computed areas under receiver operating characteristic curves monotonically increased from 0.666±0.029 to 0.730±0.027 as the time-lag between the "prior" (3 to 1) and "current" examinations decreases. The maximum adjusted odds ratios were 5.63, 7.43, and 11.1 for the three "prior" (3 to 1) sets of examinations, respectively. This study demonstrated a positive association between the risk scores generated by a bilateral mammographic feature difference based risk model and an increasing trend of the near-term risk for having mammography-detected breast cancer.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Tan M,Zheng B,Leader JK,Gur Ddoi
10.1109/TMI.2016.2527619subject
Has Abstractpub_date
2016-07-01 00:00:00pages
1719-28issue
7eissn
0278-0062issn
1558-254Xjournal_volume
35pub_type
杂志文章abstract::We consider 3-D brain structures as continuous parameterized surfaces and present a metric for their comparisons that is invariant to the way they are parameterized. Past comparisons of such surfaces involve either volume deformations or nonrigid matching under fixed parameterizations of surfaces. We propose a new mat...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2099130
更新日期:2011-03-01 00:00:00
abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126904
更新日期:1992-01-01 00:00:00
abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141650
更新日期:1992-01-01 00:00:00
abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2340912
更新日期:2015-01-01 00:00:00
abstract::Microcalcifications can be one of the earliest signs of breast cancer. Unfortunately, their appearance in mammograms can be mimicked by dust and dirt entering the imaging process and this has been shown previously to lead to false positives. We use a model of the imaging process and, in particular, the blurring functi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.811313
更新日期:1999-10-01 00:00:00
abstract::A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.476107
更新日期:1995-01-01 00:00:00
abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192694
更新日期:1992-01-01 00:00:00
abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2225152
更新日期:2013-03-01 00:00:00
abstract::The feasibility of ultrasonic Nakagami imaging to evaluate thermal lesions by high-intensity focused ultrasound and microwave ablation was explored in ex vivo and in vivo liver models. Dynamic changes of the ultrasonic Nakagami parameter in thermal lesions were calculated, and ultrasonic B-mode and Nakagami images wer...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2829934
更新日期:2018-07-01 00:00:00
abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.251116
更新日期:1993-01-01 00:00:00
abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2135374
更新日期:2011-10-01 00:00:00
abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2771504
更新日期:2018-02-01 00:00:00
abstract::Conventional Doppler ultrasound is useful for visualizing fast blood flow in large resolvable vessels. However, frame rate and tissue clutter caused by movement of the patient or sonographer make visualizing slow flow with ultrasound difficult. Patient and sonographer motion causes spectral broadening of the clutter s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2714901
更新日期:2017-09-01 00:00:00
abstract::The Newton-Raphson (N-R) with two different regularization methods: the Levenberg-Marquardt (N-R-LM) and the Hachtel's Augmented Matrix (N-R-HAM), were used to reconstruct images of conductivity changes in a cylindrical medium by Induced Current Electrical Impedance Tomography (ic-EIT). Experimental data were obtained...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.491419
更新日期:1996-01-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2281984
更新日期:2014-02-01 00:00:00
abstract::A novel splat feature classification method is presented with application to retinal hemorrhage detection in fundus images. Reliable detection of retinal hemorrhages is important in the development of automated screening systems which can be translated into practice. Under our supervised approach, retinal color images...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2227119
更新日期:2013-02-01 00:00:00
abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2372784
更新日期:2015-04-01 00:00:00
abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.883453
更新日期:2006-11-01 00:00:00
abstract::A fully automated, unsupervised lobe segmentation algorithm is presented based on a probabilistic segmentation of the fissures and the simultaneous construction of a populationmodel of the fissures. A two-class probabilistic segmentation segments the lung into candidate fissure voxels and the surrounding parenchyma. T...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2688377
更新日期:2017-08-01 00:00:00
abstract::The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2142188
更新日期:2011-09-01 00:00:00
abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2466082
更新日期:2016-01-01 00:00:00
abstract::Biomedical applications such as cell tracking and angiography require the detection of low concentrations of superparamagnetic iron oxide nanoparticles (SPIOs) for imaging purposes. Magnetic particle imaging (MPI) is a new technology which enables the quantitative and time-resolved localization of SPIO distributions. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2501462
更新日期:2016-03-01 00:00:00
abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.918326
更新日期:2008-10-01 00:00:00
abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2450831
更新日期:2015-12-01 00:00:00
abstract::The reconstruction of MR quantitative susceptibility mapping (QSM) from local phase measurements is an ill posed inverse problem and different regularization strategies incorporating a priori information extracted from magnitude and phase images have been proposed. However, the anatomy observed in magnitude and phase ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2544958
更新日期:2016-09-01 00:00:00
abstract::The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations bas...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2410342
更新日期:2015-09-01 00:00:00
abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.41493
更新日期:1989-01-01 00:00:00
abstract::With its single cell sensitivity over volumes as large as or larger than a mouse, cryo-imaging enables imaging of stem cell biodistribution, homing, engraftment, and molecular mechanisms. We developed and evaluated a highly automated software tool to detect fluorescently labeled stem cells within very large ( ∼ 200 GB...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2497285
更新日期:2016-03-01 00:00:00
abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2459764
更新日期:2016-01-01 00:00:00
abstract::In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kais...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97598
更新日期:1991-01-01 00:00:00