Classifying mammographic lesions using computerized image analysis.

Abstract:

:The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer system. An interactive segmentation procedure identified the tumor boundary using a thresholding technique which successfully segmented 57% of the lesions. Several features were chosen based on the gross and fine shape describing properties of the tumor boundaries as seen on the radiographs. Patient age was included as a significant feature in determining whether the tumor was a cyst, fibroadenoma, or cancer and was the only patient history information available for this study. The concept of a radial length measure provided a basis from which 6 of the 7 shape describing features were chosen, the seventh being tumor circularity. The feature selection process was accomplished using linear discriminant analysis and a Euclidean distance metric determined group membership. The effectiveness of the classification scheme was tested using both the apparent and the leaving-one-out test methods. The best results using the apparent test method resulted in correctly classifying 82% of the tumors segmented using the entire feature space and the highest classification rate using the leaving-one-out test method was 69% using a subset of the feature space. The results using only the shape descriptors, and excluding patient age resulted in correctly classifying 72% using the entire feature space (except age), and 51% using a subset of the feature space.

journal_name

IEEE Trans Med Imaging

authors

Kilday J,Palmieri F,Fox MD

doi

10.1109/42.251116

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

664-9

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

12

pub_type

杂志文章
  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application].

    abstract::A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476107

    authors: Pan X,Metz CE

    更新日期:1995-01-01 00:00:00

  • Assessment of perfusion by dynamic contrast-enhanced imaging using a deconvolution approach based on regression and singular value decomposition.

    abstract::The assessment of tissue perfusion by dynamic contrast-enhanced (DCE) imaging involves a deconvolution process. For analysis of DCE imaging data, we implemented a regression approach to select appropriate regularization parameters for deconvolution using the standard and generalized singular value decomposition method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.837355

    authors: Koh TS,Wu XY,Cheong LH,Lim CC

    更新日期:2004-12-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Automatic construction of parts+geometry models for initializing groupwise registration.

    abstract::Groupwise nonrigid image registration is a powerful tool to automatically establish correspondences across sets of images. Such correspondences are widely used for constructing statistical models of shape and appearance. As existing techniques usually treat registration as an optimization problem, a good initializatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2169077

    authors: Zhang P,Cootes TF

    更新日期:2012-02-01 00:00:00

  • A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution.

    abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.816960

    authors: Nuyts J,Fessler JA

    更新日期:2003-09-01 00:00:00

  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • Narrowband magnetic particle imaging.

    abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2013849

    authors: Goodwill PW,Scott GC,Stang PP,Conolly SM

    更新日期:2009-08-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00

  • Determination of optimal angiographic viewing angles: basic principles and evaluation study.

    abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276141

    authors: Dumay AM,Reiber JC,Gerbrands JJ

    更新日期:1994-01-01 00:00:00

  • EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes.

    abstract::Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoenceph...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958699

    authors: Zheng L,Liao P,Luo S,Sheng J,Teng P,Luan G,Gao JH

    更新日期:2020-06-01 00:00:00

  • An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography.

    abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2911482

    authors: Schultze B,Censor Y,Karbasi P,Schubert KE,Schulte RW

    更新日期:2020-02-01 00:00:00

  • Quantitative Susceptibility Mapping Using Structural Feature Based Collaborative Reconstruction (SFCR) in the Human Brain.

    abstract::The reconstruction of MR quantitative susceptibility mapping (QSM) from local phase measurements is an ill posed inverse problem and different regularization strategies incorporating a priori information extracted from magnitude and phase images have been proposed. However, the anatomy observed in magnitude and phase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2544958

    authors: Bao L,Li X,Cai C,Chen Z,van Zijl PC

    更新日期:2016-09-01 00:00:00

  • Vessel surface reconstruction with a tubular deformable model.

    abstract::Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiograp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974935

    authors: Yim PJ,Cebral JJ,Mullick R,Marcos HB,Choyke PL

    更新日期:2001-12-01 00:00:00

  • Clustered components analysis for functional MRI.

    abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819922

    authors: Chen S,Bouman CA,Lowe MJ

    更新日期:2004-01-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • Measurement of mean and variance of velocity fields within each voxel by NMR imaging.

    abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14520

    authors: Xiang QS,Nalcioglu O

    更新日期:1988-01-01 00:00:00

  • Robust parameter estimation of intensity distributions for brain magnetic resonance images.

    abstract::This paper presents two new methods for robust parameter estimation of mixtures in the context of magnetic resonance (MR) data segmentation. The head is constituted of different types of tissue that can be modeled by a finite mixture of multivariate Gaussian distributions. Our goal is to estimate accurately the statis...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.700730

    authors: Schroeter P,Vesin JM,Langenberger T,Meuli R

    更新日期:1998-04-01 00:00:00

  • A generative model for image segmentation based on label fusion.

    abstract::We propose a nonparametric, probabilistic model for the automatic segmentation of medical images, given a training set of images and corresponding label maps. The resulting inference algorithms rely on pairwise registrations between the test image and individual training images. The training labels are then transferre...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2050897

    authors: Sabuncu MR,Yeo BT,Van Leemput K,Fischl B,Golland P

    更新日期:2010-10-01 00:00:00

  • Using human and model performance to compare MRI reconstructions.

    abstract::Magnetic resonance imaging (MRI) reconstruction techniques are often validated with signal-to-noise ratio (SNR), contrast-to-noise ratio, and mean-to-standard-deviation ratio measured on example images. We present human and model observers as a novel approach to evaluating reconstructions for low-SNR magnetic resonanc...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.881374

    authors: Tisdall MD,Atkins MS

    更新日期:2006-11-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

    abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232251

    authors: Caorsi S,Gragnani GL,Pastorino M

    更新日期:1993-01-01 00:00:00

  • Axial resolution and the value of interpolating scan in multislice positron computed tomography.

    abstract::We have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation, and evaluated the axial resolution of a multislice PCT, Positologica III, both theoretically and experimentally. The axial point spread function (PSF) was approximately a triangle at or near the center of the fiel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307692

    authors: Senda M,Yonekura Y,Tamaki N,Tanaka Y,Komori M,Minato K,Konishi J,Torizuka K

    更新日期:1985-01-01 00:00:00

  • Detection and Localization of Ultrasound Scatterers Using Convolutional Neural Networks.

    abstract::Delay-and-sum (DAS) beamforming is unable to identify individual scatterers when their density is so high that their point spread functions overlap. This paper proposes a convolutional neural network (CNN)-based method to detect and localize high-density scatterers, some of which are closer than the resolution limit o...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3006445

    authors: Youn J,Ommen ML,Stuart MB,Thomsen EV,Larsen NB,Jensen JA

    更新日期:2020-12-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00

  • Imaging the distribution of magnetic nanoparticles with ultrasound.

    abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895476

    authors: Norton SJ,Vo-Dinh T

    更新日期:2007-05-01 00:00:00

  • Closing the Gap between Deep Neural Network Modeling and Biomedical Decision-Making Metrics in Segmentation via Adaptive Loss Functions.

    abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3031913

    authors: Seo H,Bassenne M,Xing L

    更新日期:2020-10-19 00:00:00

  • A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

    abstract::The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) al...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538946

    authors: Browne J,de Pierro AB